Command
Syntax
Parameters
Description
Treble
Txxyy<cr>
xx=zone, valid range 01-
16
yy= value, range 00-20
Adjusts the treble for a given zone. The
adjustment range is -10dB to +10db with
0dB being flat, so a yy value of 0 =
-10dB, 10 = 0dB, 20 = +10dB.
Bass
Bxxyy<cr>
xx=zone, valid range 01-
16
yy= value, range 00-20
Adjusts the bass for a given zone. The
adjustment range is -10dB to +10db with
0dB being flat, so a yy value of 0 =
-10dB, 10 = 0dB, 20 = +10dB.
Query source
name
SNxx?<cr>
xx=source, range 01-07 Returns a character string describing the
name of the queried source.
Set source name SNxxcccc<cr> xx=source, range 01-07,
cccc = a character string,
max 10 characters
Sets the name of source xx to cccc.
Example to change the name of source 2
to CABLE, issue:
SN02CABLE<cr>
Query zone
name
ZNxx?<cr>
xx=zone, range 01-16, c Returns a character string describing the
name of the queried zone.
Set zone name
ZNxxcccc<cr> xx=zone, range 01-16,
cccc = a character string,
max 16 characters
Sets the name of zone xx to cccc.
Example to change the name of zone 1 to
KITCHEN, issue:
ZN01KITCHEN<cr>
Query number
of zones
ZONES?
none
Returns the number of zones in the
system. It will be either 08, or 16 if a
slave is attached.
1.0 03/23/2011