Installation, Operation and Maintenance Manual
Scalestop 7,8,9,10 &12” Systems
© 2006-2010 next filtration technologies inc.
5
document:NSS-7-12-RES-IOM.pdf
Equipment Specifications
next-ScaleStop systems are complete, self-contained, loaded with media and ready to use. A simple
JOMFUBOEPVUMFUDPOOFDUJPOJTBMMUIBUJTSFRVJSFEGPSJOTUBMMBUJPO1MFBTFSFWJFXPQFSBUJOHQSFTTVSFT
temperatures and water chemistry limitations to ensure compatibility.
Specifications
Inlet/Outlet Connection
ww NVMUJQMFPQUJPOT
Temperature
40° - 110°F
pH
6.5 to 8.5
Ferrous Iron, Max*
0.3 mg/L
Manganese, Max*
0.05 mg/L
Copper, Max*
1.3 mg/L
8BUFS1SFTTVSF
NJONBY 14*
* See note about Iron, Manganese and Copper on the next page.
a
b
c
e
d
Mechanical Specs.
744
844
948
1054 1252
Max Service Flow (gpm)
10
12
16
20
30
Dry Weight (lbs)
22
25
29
35
43
Service Weight (lbs)
80
97
129
168
235
Dimensions
(nominal - inches)
a
48.5
48.5
52.5
59.5
56.5
b
46
46
48
57
54
c
7
8
9
10
12
d
2.5
2.5
2.5
2.5
2.5
e
3.0
3.0
3.0
3.0
3.0
Using ScaleStop with other water treatment equipment.
Due to the unique properties of ScaleStop, there are some
VOJRVFSFRVJSFNFOUTGPSVTJOH4DBMF4UPQJODPOKVODUJPOXJUI
filtration or other forms of water treatment.
1. ScaleStop must be the last stage in the treatment chain.
Do not install any filters after ScaleStop or before any de-
WJDFTGPSXIJDITDBMFQSFWFOUJPOJTSFRVJSFE106GJMUFST
e.g. carbon or RO are exempt from this requirement.
2. Do not apply phosphate or any other antiscalant either
before or after ScaleStop.