- 7 -
CABLE SELECTING
Selecting a cable consists of calculating the correct cable section (size) in relation
to the load impedance and the required cable length. A small cable section will increase its
serial resistance, which will induce power-loss and response variations (damping factor).
The following table indicates, for 3 common sizes, a cable length with a
maximum serial resistance equal to 4% of the load impedance (damping factor = 25):
Cable section
Maximum Length related to load impedance
8 Ω
4Ω
1.5 mm²
12 m [40 ft]
6 m [20 ft]
2.5 mm²
20 m [64 ft]
10 m [32 ft]
4 mm²
32 m [104 ft]
16 m [52 ft]
RIGGING SYSTEM
The LA8
V2
has a simple and intuitive four-point rigging system. It has 2
articulated joints on the front and 2 rear adjustable joints. The rear joints let you define the
angle between two elements.