1. System Power
Apply Power to the X2-CB
The X2-CB has an innovative power design that allows for simple connectivity and interfacing with sensors on
NexSens CB-Series buoys.
Power Jumper
CB-Series solar towers have a special UW-6 plug with a jumper built in that completes the circuit for the battery
to supply power to the X2-CB data logger. The X2-CB will not receive power unless the solar panel is
connected to the COM/SOLAR port. Alternatively, a UW-JUMPER plug may be connected to the COM/SOLAR
port to complete the connection.
X2-CB Buoy-Mounted Data Logger.
CB-Series jumper plug.
4