Never attempt any maintenance and/or cleaning with the
NexPump powered up Risk of electric shock may result.

IF LEAD-ACID BATTERY IS USED

WARNING - RISK OF EXPLOSIVE GASES
WORKING IN THE VICINITY OF A LEAD-ACID BATTERY
CAN BE DANGEROUS.
BATTERIES GENERATE EXPLOSIVE GASES DURING
NORMAL BATTERY OPERATION.
FOR THIS REASON, IT IS OF THE UTMOST IMPOR-
TANCE THAT EACH TIME BEFORE
USING YOUR NEXPUMP CONTROL UNIT YOU READ THIS
MANUAL AND FOLLOW THE INSTRUCTIONS EXACTLY.

Be sure the area around the battery is well
ventilated.

A SPARK NEAR THE BATTERY MAY
CAUSE AN EXPLOSION.

PERSONAL PRECAUTIONS

IF LEAD-ACID BATTERY IS USED

Someone should be within range of your voice and/or close
enough to come to your aid when
you work near a lead-acid battery.

Have plenty of fresh water and soap nearby in
case battery acid contacts skin, clothing or eyes.

Wear complete eye protection and clothing
protection. Avoid touching your eyes while
working near the battery.

If battery acid contacts skin and/or clothing, wash immediate-
ly with soap and water. If acid enters the
eye, immediately flood eye with running cold water for at
least 10 minutes and get medical attention immediately. 

When the battery fluid level is low, add distilled water in each
cell until the level reaches the
indicator on each cell. Do not overfill.

PRECAUTIONS FOR ALL BATTERIES

NEVER smoke or allow a spark or flame in the vicinity of the
battery.

Be extra cautious to reduce the risk of dropping
a metal tool onto the battery. It might spark
or short-circuit the battery or another electrical
part that may cause an explosion.

Remove personal metal items such as rings, bracelets, neck-
laces and/or watches when working with a battery. A battery
can produce a short-circuit current high enough to weld a
ring (or the like) to metal, causing a severe burn.

When Cleaning the battery terminals. Be careful to keep cor-
rosion from coming in contact with eyes.

Do not use the system unit for charging Dry-Cell batteries, that are
most commonly used with household appliances. These batteries
may burst and cause injury to persons and damage to prop-
erty.

NEXPUMP PRECAUTIONS

NEXPUMP SYSTEM UNIT LOCATION

Locate the NexPump System Unit as far away
from the battery as the DC cables permit. 

Do not operate the NexPump System Unit in an area with
restricted ventilation.

Do not set a battery on top of the NexPump
System Unit.

Do Not allow the NexPump System Unit to sit on top of the
battery.

Do not block NexPump System Unit ventilation in any way.
Allow at least 6 inches of free space from the fan exhausts
on the right side of the NexPump Unit.

Do not install the NexPump System Unit where temperatures
will be below freezing (32 degrees Fahrenheit).

Do not install the NexPump System Unit where it will be
exposed to outside elements.

DC CONNECTION PRECAUTIONS

The NexPump Unit requires a connected marine type
deep-cycle battery for proper operation. You must assure
the battery is connected while the NexPump Unit is oper-
ating.

When attaching the battery cables to the battery posts,
secure them to insure a good connection.

The BLACK wire from the NexPump System Unit 
connects to the NEGATIVE (-) post of the battery.
The RED wire from the NexPump System Unit
connects to the POSITIVE (+) post of the battery.

The ‘REVERSE POLARITY LED’ will illuminate if

the battery connections are reversed.

2

Содержание Ai2800

Страница 1: ...hone 630 365 4NEX 4639 Fax 630 365 6919 Email support nexpump com Web Address www nexpump com Manual 3 01 0002 NexPump is a Registered Trademark of NexPump Inc Copyright 2003 2010 NexPump Inc All Righ...

Страница 2: ...instructions for the NexPump Follow these important safety precautions Failure to follow safety precautions can result in personal injury or damage to the NexPump CAUTION To reduce the risk of injury...

Страница 3: ...ause an explosion Remove personal metal items such as rings bracelets neck laces and or watches when working with a battery A battery can produce a short circuit current high enough to weld a ring or...

Страница 4: ...e correct direction when installing the check valve Note If you are installing a single pump version install using Diagram A as a reference The second pump would be your installed electric pump PARTS...

Страница 5: ...the mount ing bracket at the top Verify the sensor is not tilted in any way Step 2 SECURE WIRES Secure the pump and sensor wires to discharge pipes with nylon wire ties IMPORTANT Make sure the wire t...

Страница 6: ...etup See Mode Selection NexPump Operation The NexPump will schedule an auto matic self test approximately two minutes after power up If there are any errors they will be displayed on the LCD display a...

Страница 7: ...ode position on display o NexPump WILL display and sound an alarm if pump s are activated Indicated by A in the corresponding pump location Manual Mode Used to manually turn on both pumps o Switch in...

Страница 8: ...tery Reset 8 Charging cycle will begin 9 If REP_ code sounds again soon after this procedure replace the Battery BATTERY MAINTENANCE Check Fluid levels if applicable in Battery at least once every 6 m...

Страница 9: ...n and battery state before going to battery power will affect the calculated time throughout the power loss An alarm will also sound from the loss of electric power which may silenced See Silencing th...

Страница 10: ...he pump is drawing to little current Troubleshooting H Clear alarm and run self test if pump again shows failure with H then pump is faulty Troubleshooting L Clear alarm and run self test if pump show...

Страница 11: ...e last location of the display release the function button The display will show Alarm Cleared and return to normal PUMP REPLACEMENT Displayed as R or r Pump has reached average life span Pump may sti...

Страница 12: ...electrical power cord The NexPump will remember what state the charge system was in and re enable the charging state to the condition is was when the unit was turned off After re con necting the batt...

Страница 13: ...CING THE ALARM Repeat the above section on Silencing the alarm Instead of a S displaying a U will display DISABLING THE ALARM The alarm can be disabled if needed When disabled the alarm will not sound...

Страница 14: ...s error is detected You may Disable the Alarm to stop the alarm sounding until the error is corrected Auto Notification Module Installed Notification will occur on a VRef Malfunctions Note VRef availa...

Страница 15: ...lved Auto Notification Module Installed Notification will occur on an electric power loss If the alarm was silenced within 5 minutes of the alarm the notification system will be postponed If the alarm...

Страница 16: ...ed again of the power failure Important Note Each time the alarm is cleared or after a call has been completed a notification counter is reset and will not allow the notification process to begin for...

Страница 17: ...otification occurring after a silence period during a pro longed power outage Simply switch the mode to primary This will no longer sound the alarm or Notify on pump activa tion Remember to switch the...

Страница 18: ...he Primary Mode for the duration of the event or if your main electric pump has failed 2 Sensor Alarms a High Water Alerts should NOT be cleared however the NexPump should be allowed to operate under...

Страница 19: ...d Manual Test 1 Press Function Button Until T appears 6 seconds 2 Release Function Button 3 Test is scheduled Get Serial Number 1 The NexPumps serial number is located on the rear unit or proceed to s...

Страница 20: ...d Page 12 ALDIS Alarm is disabled Resets in 5 days F Charge Status Page 11 Off Charge is off battery is fully charged Fxx Indicates the Full charge mode Txx Indicates the Trickle charge mode Mxx Indic...

Страница 21: ...prepaid properly packed and insured NexPump Inc bears trans portation cost of the repaired product back to the purchaser This warranty applied only to the original purchaser NO OTHER WARRANTIES ARE E...

Страница 22: ...21 Diagram A NexPump Ai5600 Installed as only pump Operating in Primary Mode...

Страница 23: ...22 Diagram B NexPump Ai5600 Installed with existing pump Operating in Primary or Backup Mode Recommended Configuration...

Страница 24: ...23 Diagram C NexPump Ai2800 Installed with existing pump Operating in Backup Mode ONLY...