Nexo MSub15 Скачать руководство пользователя страница 3

 

WARNINGS 

 

 

Page 3/16

 

2

 

WARNINGS 

PRECAUTIONS 

Do not open the speaker, do not try to disassemble it neither to modify it in any way. The system doesn’t include any user-repairable part.  
If the system seems to be malfunctioning or damaged, stop using it at once and have it repaired by a NEXO qualified technician. 

Do  not  expose  the  system  directly  to the sun  or to the  rain,  do  not  immerse it  into  fluids,  do  not  place  objects filled  with  liquid  on the 
system. If a liquid gets into the system, please have it inspected by a NEXO qualified technician. 

The connection should be performed by qualified technician, by ensuring that power is off. 

Operating temperature with temperate climate: 0°C to +40°C (+32°F to +104); -20°C à +60°C (-4°F to +140°F) for storage. 

SAFETY INFORMATIONS 

Read this manual before using the speaker. 

Keep this manual available for further reference. 

Observe all warnings and cautions. 

Please check the NEXO Web site 

www.nexo-sa.com 

to get the most up-to-date version of this manual. 

Ensure you are aware of the safety rules applying to rigging, stacking or installing on tripod or speaker stand. Failure to observe these 
rules may expose persons to potential wounds or even death. 

Only use the system with accessories specified by NEXO. 

Please always consult a NEXO-accredited technician if the installation needs architectural works and observe following precautions: 

Mounting Precautions: 

Please select screws and mounting location supporting 4 times the system weight. 

Do not expose the system to excessive dust, vibrations, to extreme cold or hot temperatures, to reduce the risk of damaging 
components. 

Do not place the system in an unstable position: it could fall accidentally. 

If the system is used on a tripod, please ensure the tripod’s specifications are adapted and that it’s height does not exceed 
1.40m/55”. Do not move the tripod with the system in position. 

      Connection and Powering Precautions: 

Unplug connected cables before moving the system. 

Power off the system before connecting the system. 

When switching on the installation, the amplifier must be powered last; when switching the installation off, shut off the 
amplifier first. 

If you work by cold temperatures, progressively raise the level to nominal value during the first minutes of use, to allow 
the system components to stabilize. 

Please check regularly the system condition. 

 

HIGH ACOUSTIC PRESSURE LEVELS 

Exposure to very high sound pressure levels may cause permanent hearing losses. Degrees of hearing losses may be different from one 
person to another, but almost everybody will be affected if exposed to high sound pressure levels during a long period of time. The OSHA 
(Occupational Safety and Health Administration) American Agency specified the following maximal exposures: 

Number of Hours

 

Sound Pressure Level (dBA), Slow Response

 

90 

92 

95 

97 

100 

1 ½ 

102 

105 

½ 

110 

¼ or less 

115 

WASTE OF ELECTRIC OR ELECTRONIC EQUIPMENT 

This symbol on the product or its packaging indicates that this product must not be treated as household waste. 
Instead, it is your responsibility to hand it over to a designated collection point for the recycling of waste electrical 
and electronic equipment. By ensuring your waste equipment is recycled, you will help prevent potential negative 
consequences  for  the  environment  and  human  health,  which  could  appear  if  this  product  was  not  recycled. 
Recycling helps spare natural resources. For more information about the recycling of this product, please contact 
your local city office, your household waste disposal service or your reseller. 

Содержание MSub15

Страница 1: ...User Manual DP2658 01 DI MSUB15 ...

Страница 2: ...ty declaration We NEXO SA ZA DU PRE DE LA DAME JEANNE 60128 PLAILLY France Declare under our sole responsibility that the product Loudspeaker Type MSUB15 Serial number On the product Is in conformity with the provisions of the following 2006 95 CE Low Voltage Directive directive including all applicable amendments Applied rules and standards EN ISO 12100 EN 60065 Plailly February 08th 2017 Joseph ...

Страница 3: ...accidentally If the system is used on a tripod please ensure the tripod s specifications are adapted and that it s height does not exceed 1 40m 55 Do not move the tripod with the system in position Connection and Powering Precautions Unplug connected cables before moving the system Power off the system before connecting the system When switching on the installation the amplifier must be powered la...

Страница 4: ...ws to take out or to bring in the rigging link LOCK position allows to keep the link inside Lower semi auto lock system At each lower corner you have a semi auto lock system Pull the knob in OPEN position Pull the lever up to lock the 2 MSUB15 together once in place Proceed the same way for the disassembly ...

Страница 5: ...ifferent supplier All MSUB15 accessories have been designed so that cabinet are arrayed vertically VNT BUMPM10 Rated for a maximum of 12 GEOM10 or 8 MSUB15 Maximum quantity for flown vertical cluster is NGEOM10 1 5 NMSUB15 12 2 rigging points 2 points with retractable rings Usable with VNT EXBARM10 for a one rigging point Ground stack assembly alone or with VNT GSTKM10S VNT GSTKM10L 2 locations fo...

Страница 6: ... 6 16 MSUB15 ACCESSORIES VNT GSTKM10S VNT GSTKM10L VNT MINISTACK Rated for a maximum of 3 GEOM10 on the top of MSUB15 MST WBMSUB15 MST COVMSUB15 Cover for 1x MSUB15 MST 2CASEMSUB15 Flight case for 2x MSUB15 ...

Страница 7: ... table shows the number of MSUB15 subwoofers usable with each solution NXAmp 4x1 Bridged NXAmp 4x4 DTD DTDAmp 4x1 3 MSUB15 Up to 2 per channel Up to 3 per channel 1 per channel 6 SETTING RANGE Please consult www nexo sa com for NEXO TD Controllers firmware information There are two setting ranges for speaker MSUB15 OMNI setups available on NXAMP and DTD For a traditional use of the subwoofer in om...

Страница 8: ...Page 8 16 SETTING RANGE OMNI Assembly CARDIO Assembly With 1 to 3 GEOM10 o For these configurations crossover frequency 85Hz is recommended 85 Hz also for pour GEOM10 ...

Страница 9: ...with 1 Back and 2 Front and GEOM10 on top of them cross over 85Hz is recommended 85 Hz also for GEOM10 A small overlap could have impact if needed for example MSUB15 120 Hz and GEOM10 75 Hz With 4 to 6 GEOM10 o For long throw flying application crossover 95 Hz is recommended CARDIO mode ...

Страница 10: ...ation up to 6 GEOM10 crossover 85 Hz is recommended also for GEOM10 With 7 to 12 GEOM10 o For very long throw application with flowned or stacked MSUB15 recommended MSUB15 cardioid mode cross over MSUB15 95 HZ and 12 GEOM10 cross over 75Hz for maximum impact ...

Страница 11: ... not compatible with others o Used for high power stage Monitor DJ Monitor Drum Fill Stack side o Always use same cross over between GEOM10 and MSUB15 no overlap possible without doing phase adjustment by yourself o Very high LF headroom o Clarity adjustment using 3dB on ArrayEQ 75 Hz crossover default ...

Страница 12: ...Page 12 16 ARRAY EQ 7 ARRAY EQ The ArrayEQ allows to adjust the system frequency response in its lower range see curves below with different ArrayEq values ...

Страница 13: ...ging Remove 6 screws Tx30 and the bumper Remove 8 screws TX25 on the side top and below to remove the grille 8 2 Haut parleur 15 Remove 16 screws Tx25 to remove the trap Remove 8 screws TX25 use a TX25 wrench to unscrew the 2 screws located at the front ...

Страница 14: ...ck with screws 1 05MS15CATAVR PW Bumper FR White with screws 3 1 05MS15CATARR Bumper RR Black with screws 1 05MS15CATARR PW Bumper RR White with screws 4 1 05MSUB15LEX Lexan MSUB15 5 4 05FTCC38X10 Plastic pad 38x10 with screw 6 1 05MS15CATARL Bumper RL Black with screws 1 05MS15CATAR PW Bumper RL White with screws 7 1 05MSUB15LEX WAR Lexan Warning 8 1 05MS15CATAVL Bumper FL Black with screws 1 05M...

Страница 15: ...Frequency 40 65 40 75 40 85 40 95 40 120 Hz Nominal Impedance 8Ω Recommended Amplification 900 W per cabinet SPECIFICATIONS Model MSUB15 Components 1x 15 8 Ohms Long excursion Neodymium driver Material Finnish birch plywood Finish Black or white structural paint Front finish Steel front grille Black or white paint Black or white mesh Fittings 4x Side handles Retractable rigging Semi auto lock Weig...

Страница 16: ...Page 16 16 User notes 10 USER NOTES France Nexo S A Parc d activité de la Dame Jeanne F 60128 PLAILLY Tel 33 3 44 99 00 70 Fax 33 3 44 99 00 30 E mail info nexo fr https nexo sa com ...

Отзывы: