CMS100
Product Manual, Issue 8
www.nexo.com
Page 31
3.8
Half reset (Hr)
Half resets are used to clear controller’s self learning matrix in the event that the controller has learned
incorrect opening times due to being unable to detect activity correctly.
The matrix may require clearing for reasons such as:
`
The cooler has been moved from one store, to another - with different opening times
`
The cooler has been prevented from learning due to an obstruction in front of the motion
sensor
`
The cooler is in saving mode when it is expected to be in ready mode
`
The cooler does not appear to be going into the saving mode when expected
A half reset will not:
`
Adjust, change or alter any of the parameters, or their values, as set by the OEMs or Brands.
`
Fix any issues with cable connection
Step
Action
Display
1
Press the Set button.
2
The displays shows:
3
Enter the button sequence of the main menu entry
password
4
Press the Set button four times (x 4)
5
Press the Down button twice (x 2)
6
Press the Up button once (x 1)
7
Press the Defrost button twice (x 2)
8
The display shows:
9
Press the Down button to scroll to the half re-set
option:
10
Press the set button to select the half reset option.
The display will alternate between ‘Hr’ and ‘nO’
/