FORM NO. L-21099-K-1214
6
AIR CONNECTIONS
NOTE
For quick response, Nexen recommends a quick exhaust
valve and short air lines between the Control Valves and
the product. Align the air inlet ports to a down position
to allow condensation to drain out of the air chambers
of the product.
CAUTION
Low air pressure will cause slippage and
overheating. Excessive air pressure will
cause abrupt starts and stops, reducing
product life.
All Nexen pneumatically actuated devices require clean
and dry air, which meet or exceeds ISO 8573.1:2001
Class 4.4.3 quality.
The following are common air supply schemes used with
this product. These are examples and not an all-inclusive
list. All air circuits to be used with this product must be
designed following ISO 4414 guidelines.
WARNING
Never exceed maximum operating
speeds listed for your product.
(See Table 2).
OPERATION
TABLE 2
CAUTION
The temperature limits for this
product line are 4.5-100 Degree
Celsius (40-220 Degree F).
CAUTION
Never exceed life of facing material. Facing
life depends on the volume of material and
the total energy over the life of the unit.
Expected life (in hrs) can be found by:
Time=Volume/(Power*Wear Rate).
Maximum RPM
PSI
Size 32
Size 44
Size 54
80
300
250
250
70
400
300
300
60
550
350
350
50
800
450
450
40
1000
750
750
WARNING
Ensure proper guarding of the product is
used. Nexen recommends the machine
builder design guarding in compliance
with OSHA 29 CFR 1910 “Occupational
Safety and Health Hazards”.
Air
Supply
Brake
Inlet
Gauge
Regulator
Filter
Dryer
Brake Control Circuit
Quick Exhaust
Valve
3/2 (3 Way)
N.O. Valve
AIR PRESSURE:
8 BAR (120 PSI) ABSOLUTE MAX
0 BAR (0 PSI) ABSOLUTE MIN