background image

Copyright © 2013 NEXCOM International Co., Ltd. All Rights Reserved.

35

NSA 3150 User Manual 

Chapter 3: System Setup

Notes on Rackmount Rails

When installing the rackmount kit (optional), please pay attention to the 
following:

1.  Elevated Operating Ambient - If installed in a closed or multi-unit rack 

assembly, the operating ambient temperature of the rack environment 
may be greater than room ambient. Therefore, consideration should be 
given to installing the equipment in an environment compatible with the 
maximum ambient temperature (Tma) specified by the manufacturer.

2.  Reduced Air Flow - Installation of the equipment in a rack should be such 

that the amount of air flow required for safe operation of the equipment 
is not compromised.

3.  Mechanical Loading - Mounting of the equipment in the rack should 

be such that a hazardous condition is not achieved due to uneven 
mechanical loading.

4.  Circuit Overloading - Consideration should be given to the connection 

of the equipment to the supply circuit and the effect that overloading 
of the circuits might have on overcurrent protection and supply wiring.
Appropriate consideration of equipment nameplate ratings should be 
used when addressing this concern.

5.  Reliable Earthing - Reliable earthing of rack-mounted equipment 

should be maintained. Particular attention should be given to supply 
connections other than direct connections to the branch circuit (e.g. use 
of power strips).”

Содержание NSA 3150

Страница 1: ...NEXCOM International Co Ltd NEXCOM International Co Ltd Published April 2016 www nexcom com Network and Communication Solutions Network Security Appliance NSA 3150 User Manual ...

Страница 2: ... 1 Key Features 1 Hardware Specifications 2 Knowing Your NSA 3150 3 Front Panel 3 Rear Panel 4 Chapter 2 Jumpers and Connectors Before You Begin 5 Precautions 5 Jumper Settings 6 Locations of the Jumpers and Connectors 7 Jumpers 8 RTC Clear 8 ATX AT Select 8 Console Pin Header 9 Connector Pin Definitions 10 External I O Interfaces 10 RS232 Console Port and Dual USB 2 0 Ports 10 LAN Ports 11 Reset ...

Страница 3: ...er For LAN Module 24 Chapter 3 System Setup Removing the Chassis Cover 25 Installing a SATA DOM 26 Installing DIMM Memory Modules 29 Installing a 3 5 SATA Hard Drive 30 Rackmount Bracket Kit Optional 34 Notes on Rackmount Rails 35 Chapter 4 BIOS Setup About BIOS Setup 36 When to Configure the BIOS 36 Default Configuration 37 Entering Setup 37 Legends 37 BIOS Setup Utility 39 Main 39 Advanced 40 Ch...

Страница 4: ...EXCOM International Co Ltd All other product names mentioned herein are registered trademarks of their respective owners Regulatory Compliance Statements This section provides the FCC compliance statement for Class B devices and describes how to keep the system CE compliant Declaration of Conformity FCC This equipment has been tested and verified to comply with the limits for a Class B digital dev...

Страница 5: ... Polybrominated diphenyl Ethers PBDE 0 1 or 1 000ppm In order to meet the RoHS compliant directives NEXCOM has established an engineering and manufacturing task force in to implement the introduction of green products The task force will ensure that we follow the standard NEXCOM development procedure and that all the new RoHS components and new manufacturing processes maintain the highest industry...

Страница 6: ...ective products making sure it is durable enough to be resistant against further damage and deterioration during transportation In case of damages occurred during transportation the repair is treated as Out of Warranty Any products returned by NEXCOM to other locations besides the customers site will bear an extra charge and will be billed to the customer Repair Service Charges for Out of Warranty...

Страница 7: ...nd power supply are inconsistent with these instructions or the instructions for accessory modules contact the supplier to find out how you can ensure that your computer meets safety and regulatory requirements Cautions Electrostatic discharge ESD can damage system components Do the described procedures only at an ESD workstation If no such station is available you can provide some ESD protection ...

Страница 8: ...e the soft metal or plastic parts of the connectors Safety Information Before installing and using the device note the following precautions Read all instructions carefully Do not place the unit on an unstable surface cart or stand Follow all warnings and cautions in this manual When replacing parts ensure that your service technician uses parts specified by the manufacturer Avoid using the system...

Страница 9: ...e voltage and current rating marked on the product 10 All cautions and warnings on the equipment should be noted 11 If the equipment is not used for a long time disconnect it from the power source to avoid damage by transient overvoltage 12 Never pour any liquid into an opening This may cause fire or electrical shock 13 Never open the equipment For safety reasons the equipment should be opened onl...

Страница 10: ...rsion application software etc A complete description of the problem The exact wordings of the error messages Warning 1 Handling the unit carry the unit with both hands and handle it with care 2 Maintenance to keep the unit clean use only approved cleaning products or clean with a dry cloth 3 CompactFlash Turn off the unit s power before inserting or removing a CompactFlash storage card Convention...

Страница 11: ...920 Chung Cheng Rd ZhongHe District New Taipei City 23586 Taiwan R O C Tel 886 2 8226 7796 Fax 886 2 8226 7792 Email sales nexcom com tw www nexcom com tw NEXCOM Intelligent Systems Taichung Office 16F No 250 Sec 2 Chongde Rd Beitun Dist Taichung City 406 R O C Tel 886 4 2249 1179 Fax 886 4 2249 1172 Email sales nexcom com tw www nexcom com tw Japan NEXCOM Japan 9F Tamachi Hara Bldg 4 11 5 Shiba M...

Страница 12: ...ww nexcomitalia it NEXCOM Shanghai Room 603 604 Huiyinmingzun Plaza Bldg 1 No 609 Yunlin East Rd Shanghai 200333 China Tel 86 21 5278 5868 Fax 86 21 3251 6358 Email sales nexcom cn www nexcom cn NEXCOM Surveillance Technology Room202 Building B the GuangMing Industrial Zone Zhonghua Rd Minzhi Street Longhua District Shenzhen 518000 China Tel 86 755 8364 7768 Fax 86 755 8364 7738 Email steveyang ne...

Страница 13: ... Ear Sets VER A CHYUAN JYH 79 5x43 5x26mm AL PANTONE 295U 1 5 5041110028X00 AL Handle For UTM625 VER A TENG JYE 105x64x10 5mm Color Sophos White 1 6 6012200052X00 PE Zipper Bag 8 170x240mm W China RoHS Symbol 1 7 6012200053X00 PE Zipper Bag 3 100x70mm W China RoHS Symbol 1 8 6023309081X00 Cable EDI 232091081804 RS COM Port DB9 Female To RJ45 8P8C L 1800mm 1 9 6029900037X00 Dow Corning 340 Silcone ...

Страница 14: ...xiv NSA 3150 User Manual Preface Ordering Information The following below provides ordering information for NSA 3150 Barebone NSA 3150 P N 10S00315000X0 Support 4th generation Intel Core processors 2 DDR3 memory slots 8PCIe GbE LAN ports USB ports VGA port w o LCM ...

Страница 15: ...anual Chapter 1 Product Introduction Chapter 1 Product Introduction Key Features 1U rackmount network platform 4th generation Intel Core processors Support two DDR3 1333 1600 memory up to 16GB Overview Support one PCIe x8 expansion Internal one 3 5 HDD bay two 2 5 HDD bay Optional ...

Страница 16: ...bypass 4 pairs Expansion 1x PCIe x8 slot optional 1x LAN module I O Interface Power status HDD status LAN status Bypass status LEDs 2x USB 2 0 ports 1x RJ45 type console port 8x copper LAN ports 1x LAN module I O Interface Rear 1x expansion slot optional 2x USB 2 0 ports 1x VGA port Devices 1x internal 3 5 HDD bay 2x 2 5 HDD bay optional 1x SATA DOM device space Power Input 250W ATX power supply C...

Страница 17: ...rts RJ45 type console port LCD 2x16 characters LCD module PIO interface Power LED Indicates the power status of the system HDD LED Indicates the status of the hard drive RJ45 Type Console Port Used to connect RJ45 type console port USB Ports Used to connect USB 2 0 1 1 devices Copper LAN Ports Used to connect LAN network devices Power HDD LEDs Copper LAN ports ...

Страница 18: ...Product Introduction Rear Panel AC Power Socket Expansion slot optional Expansion Slot Used to install a PCI Express x8 card VGA Used to connect an analog VGA monitor USB Ports Used to connect USB 2 0 1 1 devices AC Power Socket Plug an AC power cord here before turning on the system USB Ports VGA ...

Страница 19: ...rself before touching any internal components by touching a metal object Static electricity can damage many of the electronic components Humid environments tend to have less static electricity than dry environments A grounding strap is warranted whenever danger of static electricity exists Precautions Computer components and electronic circuit boards can be damaged by discharges of static electric...

Страница 20: ... jumpers ensure that the jumper caps are placed on the correct pins When the jumper cap is placed on both pins the jumper is short If you remove the jumper cap or place the jumper cap on just one pin the jumper is open Refer to the illustrations below for examples of what the 2 pin and 3 pin jumpers look like when they are short on and open off Two Pin Jumpers Open Left and Short Right Three Pin J...

Страница 21: ...ctors Locations of the Jumpers and Connectors The figure below shows the location of the jumpers and connectors JUSB1 JVGA1 FAN2 FAN1 CON1 CON2 J2 JP1 JWDTO1 SATA1 SATA2 SATA3 JKBMS1 COM1 CN1 JPWRBTN1 JRST1 JP6 SW1 LED9 CN2 JP5 J10 CON5 CON3 FAN4 JP3 JP2 J3 GFM1 JPRSNT1 PCIE1 FAN3 JINTRUDER J9 J12 J11 JP4 J8 J6 J5 ...

Страница 22: ... RTC Clear Connector type 1x3 3 pin header 2 54mm pitch Connector location JP2 ATX AT Select Connector type 1x3 3 pin header 2 54mm pitch Connector location JP1 1 3 1 3 Pin Definition 1 VCCRTC 2 RTC_RST 3 GND Pin Function 1 2 ATX Mode 2 3 AT Mode Pin Function 1 2 Normal 2 3 Clear CMOS Pin Definition 1 NC 2 AT_ATX_SELECT 3 GND ...

Страница 23: ...hts Reserved 9 NSA 3150 User Manual Chapter 2 Jumpers and Connectors Console Pin Header Connector type 1x3 3 pin header 2 54mm pitch Connector location JP5 1 3 Pin Description 1 SP_RTS1_R 2 SP_CTS1_R 3 SP_CTS1_CON Pin Function 1 2 RTS to CTS 2 3 Normal ...

Страница 24: ...ces RS232 Console Port and Dual USB 2 0 Ports Connector type RJ45 port with LEDs Dual USB 2 0 ports Type A Connector location CN2 9 8 4 16 5 1 Pin Definition Pin Definition 9 SP_RTS1_R 10 SP_DTR1_R 11 SP_TXD1_R 12 GND 13 SP_DCD1_R 14 SP_RXD1_R 15 SP_DSR1_R 16 SP_CTS1_CON Pin Definition Pin Definition 1 5VDUAL 5 5VDUAL 2 USB2 6 USB3 3 USB2 7 USB3 4 GND 8 GND LAN USB ...

Страница 25: ...CON B6 LAN2_TXN1_CON B7 LAN2_TXP3_CON B8 LAN2_TXN3_CON B9 LAN2_LED_LINK1G B10 LAN2_LED_LINK100 B11 LAN2_LED_ACT B12 LAN2_ACTPW Pin Definition Pin Definition C1 LAN3_TXP0_CON C2 LAN3_TXN0_CON C3 LAN3_TXP1_CON C4 LAN3_TXP2_CON C5 LAN3_TXN2_CON C6 LAN3_TXN1_CON C7 LAN3_TXP3_CON C8 LAN3_TXN3_CON C9 LAN3_LED_LINK1G C10 LAN3_LED_LINK100 C11 LAN3_LED_ACT C12 LAN3_ACTPW D1 LAN4_TXP0_CON D2 LAN4_TXN0_CON D...

Страница 26: ...4 LAN6_TXP2_CON B5 LAN6_TXN2_CON B6 LAN6_TXN1_CON B7 LAN6_TXP3_CON B8 LAN6_TXN3_CON B9 LAN6_LED_LINK1G B10 LAN6_LED_LINK100 B11 LAN6_LED_ACT B12 LAN6_ACTPW Pin Definition Pin Definition C1 LAN7_TXP0_CON C2 LAN7_TXN0_CON C3 LAN7_TXP1_CON C4 LAN7_TXP2_CON C5 LAN7_TXN2_CON C6 LAN7_TXN1_CON C7 LAN7_TXP3_CON C8 LAN7_TXN3_CON C9 LAN7_LED_LINK1G C10 LAN7_LED_LINK100 C11 LAN7_LED_ACT C12 LAN7_ACTPW D1 LAN...

Страница 27: ...Copyright 2013 NEXCOM International Co Ltd All Rights Reserved 13 NSA 3150 User Manual Chapter 2 Jumpers and Connectors Reset Button Connector location SW1 Pin Definition 1 GND 2 SW_BTN_IN 1 2 ...

Страница 28: ...10 pin header 2 0mm pitch Connector location J8 Pin Definition Pin Definition 1 VCC5 2 GND 3 SIO_GP32 4 SIO_GP06 5 SIO_GP03 6 SIO_GP07 7 SIO_GP04 8 SIO_GP76 9 SIO_GP05 10 SIO_GP77 1 9 2 10 COM 2 Box Header Connector Connector type 2x5 10 pin header 2 0mm pitch Connector location COM1 Pin Definition Pin Definition 1 SP_DCD2 2 SP_RXD2 3 SP_TXD2 4 SP_DTR2 5 GND 6 SP_DSR2 7 SP_RTS2 8 SP_CTS2 9 SP_RI2 ...

Страница 29: ...nectors USB2 JST Header Connector Connector type 1x6 6 pin header 2 0mm pitch Connector location JUSB1 Pin Definition Pin Definition 1 5VDUAL 2 USB0 3 USB0 4 USB1 5 USB1 6 GND 1 6 HW Reset Pin Header Connector type 1x2 2 pin header 2 54mm pitch Connector location JRST1 Pin Definition 1 PCH_SYS_RESET_N_R 2 GND 1 2 ...

Страница 30: ...pin header 2 54mm pitch Connector location JPWRBTN1 Bypass LED Pin Header Connector type 1x2 2 pin header 2 54mm pitch Connector location J9 J10 J11 and J12 Pin Definition 1 GND 2 FP_PWRBTN_N Pin Definition 1 VCC3 2 BYPASS_LED_S4 Pin Definition 1 VCC3 2 BYPASS_LED_S3 Pin Definition 1 VCC3 2 BYPASS_LED_S2 Pin Definition 1 VCC3 2 BYPASS_LED_S1 1 2 1 2 J9 J11 J12 J12 ...

Страница 31: ...AL Programming Connector Connector type 1x6 6 pin header 2 54mm pitch Connector location J2 1 6 Pin Definition Pin Definition 1 3VSB 2 GND 3 GAL_TCK 4 GAL_TDO 5 GAL_TDI 6 GAL_TMS Power Connector Connector type 1x4 4 pin header 5 08mm pitch Connector location J3 Pin Definition Pin Definition 1 VCC12 2 GND 3 GND 4 VCC5 1 4 ...

Страница 32: ...Connectors System Fan Connectors 4 Pin Connector type 1x4 4 pin Wafer 2 54mm pitch Connector location FAN1 and FAN3 System Fan Connectors 3 Pin Connector type 1x3 3 pin Wafer 2 54mm pitch Connector location FAN2 and FAN4 Pin Definition 1 GND 2 VCC12 3 Sense 4 FANPWM Pin Definition 1 GND 2 VCC12 3 Sense 1 4 1 3 ...

Страница 33: ...Pin Definition Pin Definition 1 GND 2 SATA_TX0P 3 SATA_TX0N 4 GND 5 SATA_RX0N 6 SATA_RX0P 7 GND Pin Definition Pin Definition 1 GND 2 SATA_TX1P 3 SATA_TX1N 4 GND 5 SATA_RX1N 6 SATA_RX1P 7 GND Pin Definition Pin Definition 1 GND 2 SATA_TX2P 3 SATA_TX2N 4 GND 5 SATA_RX2N 6 SATA_RX2P 7 GND 1 7 SATA2 SATA3 SATA1 SATA DOM Power Port Connector type 1x2 2 pin header 2 5mm pitch Connector location J5 Pin ...

Страница 34: ... Connector location JKBMS1 Pin Definition Pin Definition 1 VCC5 2 VCC5 3 KDAT 4 MDAT 5 KCLK 6 MCLK 7 GND 8 GND 1 7 2 8 VGA Connector Connector type 2x8 16 pin header 2 0mm pitch Connector location JVGA1 Pin Definition Pin Definition 1 RED_VGA 2 GREEN_VGA 3 BLUE_VGA 4 NC 5 GND 6 GND 7 GND 8 GND 9 VGA_ 5V 10 GND 11 NC 12 DDC_DATA_VGA 13 HSYNC_VGA 14 VSYNC_VGA 15 DDC_CLK_VGA 16 NC 1 2 15 16 ...

Страница 35: ...ion JP6 1 4 Pin Definition Pin Definition 1 KEY_PIN1 2 KEY_PIN2 3 KEY_PIN3 4 KEY_PIN4 Parallel Interface for LCM Module Connector type 2x8 16 pin header 2 54mm pitch Connector location CN1 Pin Definition Pin Definition 1 VCC5 2 GND 3 LPT_SLIN R 4 LPT_RES 5 LPT_AFD R 6 LPT_INIT R 7 LPT_PDR1 8 LPT_PDR0 9 LPT_PDR3 10 LPT_PDR2 11 LPT_PDR5 12 LPT_PDR4 13 LPT_PDR7 14 LPT_PDR6 15 LPT_PW 16 VCC5 1 2 15 16...

Страница 36: ...ation CON1 Power Connector Connector type 2x2 4 pin header 3 5mm pitch Connector location CON2 Pin Definition Pin Definition 1 VCC3 2 VCC3 3 GND 4 VCC5 5 GND 6 VCC5 7 GND 8 ATXPWROK 9 5VSB 10 VCC12 11 VCC12 12 VCC3 13 VCC3 14 NVCC12 15 GND 16 SIO_PSON_N 17 GND 18 GND 19 GND 20 GND 21 VCC5 22 VCC5 23 VCC5 24 GND Pin Definition Pin Definition 1 GND 2 GND 3 VCC12_CPU 4 VCC12_CPU 1 12 13 24 1 2 3 4 ...

Страница 37: ... GND A17 PEG_SRXN0 B17 PCIe_PRSNT A18 GND B18 GND A19 NC B19 PEG_STXP1 A20 GND B20 PEG_STXN1 A21 PEG_SRXP1 B21 GND Pin Definition Pin Definition A22 PEG_SRXN1 B22 GND A23 GND B23 PEG_STXP2 A24 GND B24 PEG_STXN2 A25 PEG_SRXP2 B25 GND A26 PEG_SRXN2 B26 GND A27 GND B27 PEG_STXP3 A28 GND B28 PEG_STXN3 A29 PEG_SRXP3 B29 GND A30 PEG_SRXN3 B30 NC A31 GND B31 PCIe_PRSNT A32 NC B32 GND A33 NC B33 PEG_STXP4...

Страница 38: ...LOT1_DN B16 3VSB A17 VCC3_3 B17 USB_4P A18 CLK_GF_33M B18 USB_4N A19 VCC3_3 B19 VCC3_3 A20 AUX_TEMP B20 VCC3_3 A21 CPU B21 VCC3_3 Pin Definition Pin Definition A22 ATX_PWROK_A1 B22 ATX_PWROK_A1 A23 ATX_PWROK_A1 B23 ATX_PWROK_A1 A24 GND B24 GND A25 PEG_TXP0 B25 PEG_RXP0 A26 PEG_TXN0 B26 PEG_RXN0 A27 GND B27 GND A28 PEG_TXP1 B28 PEG_RXP1 A29 PEG_TXN1 B29 PEG_RXN1 A30 GND B30 GND A31 PEG_TXP2 B31 PEG...

Страница 39: ...e cover to remove it Chapter 3 System Setup Removing the Chassis Cover 1 Remove the screws on the chassis cover then put them in a safe place for later use CAUTION CAUTION CAUTION Prior to removing the chassis cover make sure the unit s power is off and disconnected from the power sources to prevent electric shock or system damage Lift here Screws on the side ...

Страница 40: ... 2013 NEXCOM International Co Ltd All Rights Reserved 26 NSA 3150 User Manual Chapter 3 System Setup Installing a SATA DOM 1 Locate the SATA DOM connector on the board 2 Fasten a copper post on the mounting hole ...

Страница 41: ...M International Co Ltd All Rights Reserved 27 NSA 3150 User Manual Chapter 3 System Setup 3 Install the SATA DOM to the connector with the mounting hole aligned to the copper post 4 Fasten a screw on top of the copper post ...

Страница 42: ...Copyright 2013 NEXCOM International Co Ltd All Rights Reserved 28 NSA 3150 User Manual Chapter 3 System Setup 5 Connect the power cable to the power connector on the board ...

Страница 43: ...ing DIMM Memory Modules 1 Locate the DIMM sockets on the board 2 Release the locks on the DIMM sockets 3 Insert the module into the socket at an 90 degree angle Apply firm even pressure to each end of the module until it slips into the socket 4 While pushing the DIMM into the position the lock will close automatically ...

Страница 44: ...ard Drive Please correctly follow the below instructions and noted items to avoid making unnecessary damages 2 Place the SATA hard drive into the drive bay with the SATA connector facing outwards 1 Remove the mounting screws that secure the drive bay to the chassis Mounting screw CAUTION CAUTION CAUTION SATA data and power connector ...

Страница 45: ... the SATA drive with the mounting holes on the drive bay Use the provided mounting screws to secure the SATA drive in place 5 Place the drive into the chassis with the connector side facing the board and then use the provided mounting screws to secure the drive bay in place 4 Repeat step 3 for securing the screws on the other side of the HDD tray Connector side ...

Страница 46: ... 32 NSA 3150 User Manual Chapter 3 System Setup 6 Locate the SATA data connector on the board 7 Plug the SATA data cable onto the connector then plug the other end to the SATA data connector on the hard drive SATA data connector SATA data cable SATA data connector ...

Страница 47: ...Copyright 2013 NEXCOM International Co Ltd All Rights Reserved 33 NSA 3150 User Manual Chapter 3 System Setup 8 Plug the SATA power cable to the SATA power connector on the hard drive SATA power cable ...

Страница 48: ...g Rack Ears The long rack ears are used to support the server in a rack cabinet 1 The rackmount bracket kit comes with a pair of long rack ears and 16 screws 2 There are 8 mounting holes on each side of the front panel Mounting holes Rack ear 3 Align the mounting holes on the rack ear with the mounting holes on the front panel Give special attention to the orientation of the rack ear Secure the ra...

Страница 49: ...ent in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised 3 Mechanical Loading Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading 4 Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect that ...

Страница 50: ... is configured with the values found in CMOS With easy to use pull down menus you can configure such items as Hard drives diskette drives and peripherals Video display type and display options Password protection from unauthorized use Power management features The settings made in the setup program affect how the computer performs It is important therefore first to try to understand all the setup ...

Страница 51: ...red the error will be reported in one of two different ways If the error occurs before the display device is initialized a series of beeps will be transmitted If the error occurs after the display device is initialized the screen will display the error message Powering on the computer and immediately pressing allows you to enter Setup Legends Key Function Moves the highlight left or right to selec...

Страница 52: ...up screen it indicates that there are more available fields not shown on the screen Use the up and down arrow keys to scroll through all the available fields Submenu When appears on the left of a particular field it indicates that a submenu which contains additional options are available for that field To display the submenu move the highlight to that field and press ...

Страница 53: ...ized Defaults F4 Save Exit ESC Exit Choose the system default language BIOS Information BIOS Vendor Core Version Compliancy Project Version Build Date and Time Total Memory Memory Frequency System Language System Date System Time Access Level American Megatrends 4 6 5 4 UEFI 2 3 1 PI 1 2 G653 0 10 x64 03 19 2014 13 49 56 8192 MB DDR3 1600 Mhz English Wed 05 20 2009 05 29 25 Administrator System Da...

Страница 54: ... Advanced Chipset Boot Security Main Version 2 15 1236 Copyright C 2012 American Megatrends Inc Aptio Setup Utility Copyright C 2012 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit PCI PCI X and PCI Express Settings PCI Subsystem Settings ACPI Settings CPU Configuration Network Configuration SA...

Страница 55: ...alette Snoop PERR Generation SERR Generation PCI Express Settings V 2 05 02 32 PCI Bus Clocks Disabled Disabled Disabled PCI Latency Timer This feature is used to select the length of time each PCI device will control the bus before another takes over The larger the value the longer the PCI device can retain control of the bus Since each access to the bus comes with an initial delay before any tra...

Страница 56: ...Setup Utility Copyright C 2012 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Enables or Disables BIOS ACPI Auto Configuration ACPI Settings Enable ACPI Auto Conf Lock Legacy Resources Disabled Disabled Enable ACPI Auto Conf Enables or disables BIOS ACPI auto configuration Lock Legacy Resource...

Страница 57: ... and Linux which are optimized for Hyper Threading technology Select disabled for other OSes not optimized for Hyper Threading technology When disabled only one thread per enabled core is enabled Overclocking Lock Enables or disables overclocking lock Intel Virtualization When this field is set to Enabled the VMM can utilize the additional hardware capabilities provided by Vanderpool Technology Ad...

Страница 58: ...r SATA Mode Selection Configures the SATA as IDE or AHCI mode IDE This option configures the Serial ATA drives as Parallel ATA physical storage device AHCI This option configures the Serial ATA drives to use AHCI Advanced Host Controller Interface AHCI allows the storage driver to enable the advanced Serial ATA features which will increase storage performance Advanced Version 2 15 1236 Copyright C...

Страница 59: ... Software Preserve Port 4 Hot Plug External SATA SATA Device Type Spin Up Device Enabled Disabled Disabled Hard Disk Drive Disabled Empty Unknown Enabled Disabled Disabled Hard Disk Drive Disabled Empty Unknown Enabled Disabled Disabled Hard Disk Drive Disabled SATA Test Mode Enables or disables SATA test mode Aggressive LPM Support Enables or disables agressive LPM support SATA Controller Speed C...

Страница 60: ...t Device power up delay 8 10 27 Enabled Disabled Enabled 20 sec 20 sec Auto Legacy USB Support Enable Enables Legacy USB Auto Disables support for Legacy when no USB devices are connected Disable Keeps USB devices available only for EFI applications EHCI Hand Off This is a workaround for OSs that does not support EHCI hand off The EHCI ownership change should be claimed by the EHCI driver USB Mass...

Страница 61: ...on Configuration settings for serial port 1 Parallel Port Configuration Configuration settings for parallel port Advanced Version 2 15 1236 Copyright C 2012 American Megatrends Inc Aptio Setup Utility Copyright C 2012 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Set Parameters of Serial Port...

Страница 62: ...r Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit PC Health Status System Temperature LAN Module Temperature CPU Temperature LAN Module Fan Speed Smart FAN1 Speed Smart FAN2 Speed PCH Fan Speed Fan1 Speed VCORE DRAM Voltage VCC5 VCC12 VCC3 32 C N A 31 C N A N A 2824 RPM N A N A 1 768 V 1 520 V 5 080 V 12 288 V 3 216 V Smart Fan1 Speed and Smart Fan2...

Страница 63: ...able or Disable COM0 Console Redirection Console Redirection Settings Serial Port for Out of Band Management Windows Emergency Management Services EMS Console Redirection Console Redirection Settings Enabled Enabled Console Redirection Enables or disables the console redirection Network Stack This section is used to configure the network stack Advanced Version 2 15 1236 Copyright C 2012 American M...

Страница 64: ...iguration System Agent SA Configuration PCH IO Configuration This field is used to configure PCH parameters System Agent SA Configuration This field is used to configure System Agent SA parameters PCH IO Configuration This section is used to configure PCH IO settings SLP_S4 Assertion Width Select a minimum assertion width of the SLP_S4 signal Chipset Version 2 15 1236 Copyright C 2012 American Meg...

Страница 65: ...ds Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Check to enable VT d function on MCH System Agent Bridge N System Agent RC Version VT d Capability VT d Enable NB CRID BDAT ACPI Table Support Graphics Configuration Memory Configuration GT Power Management Control Haswell 1 6 0 0 Supported Enabled Disabled Disabl...

Страница 66: ...egatrends Inc Aptio Setup Utility Copyright C 2012 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Number of seconds to wait for setup activation key 65535 0xFFFF means indefinite waiting Boot Configuration Setup Prompt Timeout Bootup NumLock State Quiet Boot Fast Boot Boot Option Priorities CS...

Страница 67: ...r s password Save Exit Save Changes and Exit To save the changes and exit the Setup utility select this field then press Enter A dialog box will appear Confirm by selecting Yes You can also press F4 to save and exit Setup Discard Changes and Exit To exit the Setup utility without saving the changes select this field then press Enter You may be prompted to confirm again before exiting You can also ...

Страница 68: ...d then press Enter A dialog box will appear Confirm by selecting Yes to discard all changes made and restore the previously saved settings Restore Defaults To restore the BIOS to default settings select this field then press Enter A dialog box will appear Confirm by selecting Yes Save as User Defaults To use the current configurations as user default settings for the BIOS select this field then pr...

Страница 69: ...d Unused Unused Unused Unused Global Timeout Value Power ON State Bypass Control Status Register Offset 0xF3 7 6 5 4 3 2 1 0 R W R W R W R W R W R W R W Bypass Mode Segment6 Segment5 Segment4 Segment3 Segment2 Segment1 Power OFF State Bypass Control Status Register Offset 0xF7 7 6 5 4 3 2 1 0 R W R W R W R W R W R W R W R W Unused Unused Segment6 Segment5 Segment4 Segment3 Segment2 Segment1 PCB an...

Страница 70: ... 0 Timer Value 000 0 second timer immediately expired 001 1 second 010 2 second 011 4 second 100 8 second 101 16 second 110 32 second 111 64 second This register is available in Timer Enable mode Timer value of 1 to 7 is required to be written before expiration of the hardware timer When the timer expires both segment relays which have been enabled will close Note The timer will recount while read...

Страница 71: ...ister F7 Bit Field Name Value 5 0 Segment 6 to 1 Segment bypass function control on Power OFF state Bit x corresponds to segment x 1 ex Bit0 control to segment1 Bit5 control to segment6 0 Segment x disable 1 Segment x enable 7 6 Unused Unused Slot Select Register F9 Bit Field Name Value 7 0 Slot ID bit 7 to 0 Main board The bypass function workable while Slot ID set to 0x00h Lan module The bypass ...