background image

Copyright © 2013 NEXCOM International Co., Ltd. All Rights Reserved.

4

NISE 90 User Manual 

Chapter 1: Product Introduction

Rear Panel

12C/24V DC Input

12/24V DC Input

3-pin terminal block connector used to plug to a DC power supply.

GPO and GPI

The GPO and GPI connectors support 8-channel GPO and 8-channel GPI.

VGA

Used to connect an analog VGA monitor.

Power Button

Press to power-on or power-off the system.

VGA

GPI

Power Button

GPO

Содержание NISE 90

Страница 1: ...NEXCOM International Co Ltd NEXCOM International Co Ltd Published August 2013 www nexcom com Industrial Computing Solutions Fanless Computer NISE 90 User Manual ...

Страница 2: ...Specifications 2 Knowing Your NISE 90 3 Mechanical Dimensions 5 NISE 90 5 Chapter 2 Jumpers and Connectors Before You Begin 6 Precautions 6 Jumper Settings 7 Locations of the Jumpers and Connectors for NISB 90 8 Jumpers 9 RTC Clear Pin Header 9 LVDS Backlight Power Select Pin Header 9 Connector Pin Definitions 10 External I O Interfaces Front Panel 10 LAN1 and LAN2 Ports 10 USB0 USB1 and USB2 Port...

Страница 3: ...ector 22 Mini PCIe Connector 23 Chapter 3 System Setup Removing the Chassis Cover 24 Installing a SATA Hard Drive 25 Installing a Wireless LAN Module half size 27 Installing a SIM Card 29 Chapter 4 BIOS Setup About BIOS Setup 31 When to Configure the BIOS 31 Default Configuration 32 Entering Setup 32 Legends 32 BIOS Setup Utility 34 Main 34 Advanced 35 Chipset 43 Boot 45 Security 47 Save Exit 47 A...

Страница 4: ...XCOM International Co Ltd All other product names mentioned herein are registered trademarks of their respective owners Regulatory Compliance Statements This section provides the FCC compliance statement for Class B devices and describes how to keep the system CE compliant Declaration of Conformity FCC This equipment has been tested and verified to comply with the limits for a Class B digital devi...

Страница 5: ...ybrominated diphenyl Ethers PBDE 0 1 or 1 000ppm In order to meet the RoHS compliant directives NEXCOM has established an engineering and manufacturing task force to implement the introduction of green products The task force will ensure that we follow the standard NEXCOM development procedure and that all the new RoHS components and new manufacturing processes maintain the highest industry qualit...

Страница 6: ...ective products making sure it is durable enough to be resistant against further damage and deterioration during transportation In case of damages occurred during transportation the repair is treated as Out of Warranty Any products returned by NEXCOM to other locations besides the customers site will bear an extra charge and will be billed to the customer Repair Service Charges for Out of Warranty...

Страница 7: ...nd power supply are inconsistent with these instructions or the instructions for accessory modules contact the supplier to find out how you can ensure that your computer meets safety and regulatory requirements Cautions Electrostatic discharge ESD can damage system components Do the described procedures only at an ESD workstation If no such station is available you can provide some ESD protection ...

Страница 8: ... the soft metal or plastic parts of the connectors Safety Information Before installing and using the device note the following precautions Read all instructions carefully Do not place the unit on an unstable surface cart or stand Follow all warnings and cautions in this manual When replacing parts ensure that your service technician uses parts specified by the manufacturer Avoid using the system ...

Страница 9: ...e voltage and current rating marked on the product 10 All cautions and warnings on the equipment should be noted 11 If the equipment is not used for a long time disconnect it from the power source to avoid damage by transient overvoltage 12 Never pour any liquid into an opening This may cause fire or electrical shock 13 Never open the equipment For safety reasons the equipment should be opened onl...

Страница 10: ...sion application software etc A complete description of the problem The exact wordings of the error messages Warning 1 Handling the unit carry the unit with both hands and handle it with care 2 Maintenance to keep the unit clean use only approved cleaning products or clean with a dry cloth 3 CompactFlash Turn off the unit s power before inserting or removing a CompactFlash storage card Conventions...

Страница 11: ...www nexcom jp com China NEXCOM China 2F Block 4 Venus Plaza Building 21 ZhongGuanCun Software Park No 8 Dongbeiwang West Road Haidian District Beijing 100193 China Tel 86 10 8282 5880 Fax 86 10 8282 5955 Email sales nexcom cn www nexcom cn Shanghai Office Room 1505 Greenland He Chuang Bldg No 450 Caoyang Rd Shanghai 200062 China Tel 86 21 6150 8008 Fax 86 21 3251 6358 Email sales nexcom cn www nex...

Страница 12: ...40 90 31 01 Email sales fr nexcom eu www nexcom eu Germany NEXCOM GmbH Leopoldstraße Business Centre Leopoldstraße 244 80807 Munich Germany Tel 49 89 208039 278 Fax 49 89 208039 279 Email sales de nexcom eu www nexcom eu Italy NEXCOM ITALIA S r l Via Gaudenzio Ferrari 29 21047 Saronno VA Italia Tel 39 02 9628 0333 Fax 39 02 9286 9215 Email nexcomitalia nexcom eu www nexcomitalia it United Kingdom ...

Страница 13: ...e NISE 90 package that you received is complete Your package should have all the items listed in the following table Item Part Number Name Qty 1 4NCPM00302X00 Terminal Blocks 3P Phoenix Contact 1777992 1 2 50311F0110X00 Flat Head Screw Long FEI F3x5ISO NYLOK NIGP 4 3 60177A0238X00 NISB90 Quick Reference Guide 1 4 602DCD0428X00 NISE90 CD Driver 1 ...

Страница 14: ...rdering Information The following information below provides ordering information for NISE 90 Barebone NISE 90 P N 10J00009000X0 Intel Atom E620 0 6GHz DIN Rail Fanless System with 512MB Memory onboard NISE 91 P N 10J00009100X0 Intel Atom E640 1 0GHz DIN Rail Fanless System with 1G Memory onboard ...

Страница 15: ...er 1 Product Introduction Chapter 1 Product Introduction Key Features On board Intel Atom E620 processor 0 6GHz On board DDR2 512MB memory chip 2x Intel GbE LANs 3x USB2 0 1x VGA 3x Serial Ports 1x CAN bus 8CH GPI and 8CH GPO Support 1x 2 5 HDD drive bay Support 12V and 24VDC input Overview ...

Страница 16: ...otocol Support both 11 bit and 26 bit identifiers Support bit rates up to 1Mbps Clock frequency of 40MHz I O Interface Bottom 1x DB15 VGA port 1x DB15 male connector for 8CH General Purpose Input 1x DB15 male connector for 8CH General Purpose Output 3 pin DC input support 12VDC input and 24VDC input 1x Power on off switch Supported OS Windows XP Windows Embedded Standard 2009 Fedora 14 Kernnel 2 6...

Страница 17: ...RS422 RS485 DB 9 CAN bus connector and serial port used to connect RS232 422 485 compatible serial devices COM3 and COM2 Serial ports used to connect RS232 compatible devices LED Indicators Two LEDs for HDD access and power status of the system Two LEDs indicators for COM port TX and RX signals two programmable GPIO LEDs and a LED for battery power replace battery when this LED is active Front Pan...

Страница 18: ...ion Rear Panel 12C 24V DC Input 12 24V DC Input 3 pin terminal block connector used to plug to a DC power supply GPO and GPI The GPO and GPI connectors support 8 channel GPO and 8 channel GPI VGA Used to connect an analog VGA monitor Power Button Press to power on or power off the system VGA GPI Power Button GPO ...

Страница 19: ... International Co Ltd All Rights Reserved 5 NISE 90 User Manual Chapter 1 Product Introduction Mechanical Dimensions A B DIN RAIL CLIP 167 00 139 60 144 60 58 79 12 50 25 00 16 00 28 00 18 00 12 50 25 00 18 00 28 00 NISE 90 ...

Страница 20: ...self before touching any internal components by touching a metal object Static electricity can damage many of the electronic components Humid environments tend to have less static electricity than dry environments A grounding strap is warranted whenever danger of static electricity exists Precautions Computer components and electronic circuit boards can be damaged by discharges of static electrici...

Страница 21: ... jumpers ensure that the jumper caps are placed on the correct pins When the jumper cap is placed on both pins the jumper is short If you remove the jumper cap or place the jumper cap on just one pin the jumper is open Refer to the illustrations below for examples of what the 2 pin and 3 pin jumpers look like when they are short on and open off Two Pin Jumpers Open Left and Short Right Three Pin J...

Страница 22: ...H4 1 2 J17 1 2 19 20 CN4 1 J8 7 1 J6 CN3 1 15 17 51 2 16 18 52 2 1 14 13 JP1 4 1 4 1 4 1 LED1 A1 C1 A2 A3 A4 C2 C3 C4 LED2 A1 C1 A2 A3 A4 C2 C3 C4 USB1 9 12 1 4 COP1 A11 B11 B14 A14 A1 B1 A10 B10 Y G F6 H9 H10 Q11 Q5 D 1 7 J4 J5 7 1 J2 2 8 7 1 1 3 CN2 CN1 2 1 4 CN5 1 4 1 6 J9 BZ1 4 VGA1 14 3 5 10 1 6 8 12 11 15 JP2 1 3 JP12 1 3 JP5 1 3 FB1 G U1 U59 C223 C10 C127 C720 C9 R900 R877 R58 NISB90 4BJ000...

Страница 23: ...umpers RTC Clear Pin Header Connector type 1x3 3 pin header 2 54mm pitch Connector location JP5 Pin Settings 1 2 On Normal 2 3 On Clear BIOS 1 2 On default Pin Settings 1 2 On 3 3V 2 3 On 5V 1 2 On default 1 3 1 3 LVDS Backlight Power Select Pin Header Connector type 1x3 3 pin header 2 54mm pitch Connector location JP12 ...

Страница 24: ...y Green 100Mbps network link Off 10Mbps network link Act Status Flashing Orange Data activity Off No activity B8 A1 LAN1 LAN2 B1 A8 Pin Definition Pin Definition A1 LAN1_M0P A8 LAN1_M3N A2 LAN1_M0N A9 VCC A3 LAN1_M1P A10 GND A4 LAN1_M1N A11 LAN1_ACTP A5 LAN1_M2P A12 LAN1_LED_ACT A6 LAN1_M2N A13 LAN1_LINKP A7 LAN1_M3P A14 LAN1LINKMIX Pin Definition Pin Definition B1 LAN2_M0P B8 LAN2_M3N B2 LAN2_M0N...

Страница 25: ...5 5V 6 Data 1 7 Data 1 8 GND USB0 USB1 and USB2 Ports Connector type Triple USB 2 0 ports Type A Connector location USB1 1 5 9 4 USB0 USB1 USB2 8 12 CAN 1 5 6 9 COM 1 10 14 15 18 Pin Definition Pin Definition 1 ISO_VCC5 OPTION 6 ISO_GND 2 CANL 7 CANH 3 ISO_GND 8 NA 4 NA 9 ISO_VCC5 OPTION 5 NA RS232 RS485 RS422 Pin Definition Pin Definition Pin Definition 10 DCD1 10 DATA 10 TX 11 RXD1 11 DATA 11 TX...

Страница 26: ... 1 5 6 9 COM 2 10 14 15 18 Pin Definition Pin Definition 1 DCD3 6 DSR3 2 RXD3 7 RTS3 3 TXD3 8 CTS3 4 DTR3 9 RI3 5 GND Pin Definition Pin Definition 10 DCD2 15 DSR2 11 RXD2 16 RTS2 12 TXD2 17 CTS2 13 DTR2 18 RI2 14 GND External I O Interfaces Rear Panel VGA Connector Connector type DB 15 15 pin D Sub VGA Connector location VGA1 Pin Definition Pin Definition 1 Red 9 5V 2 Green 10 GND 3 Blue 11 N C 4...

Страница 27: ...Definition Pin Definition Pin Definition 1 SIO_GPO21 10 GND 2 SIO_GPO24 11 SIO_GPO22 3 SIO_GPO27 12 SIO_GPO25 4 VCC5 13 SIO_GPO28 5 GND 14 SIO_GPO29 6 SIO_GPO20 15 NA 7 SIO_GPO23 MH1 GND 8 SIO_GPO26 MH2 GND 9 VCC5 GPI Connector Pin Definition Pin Definition Pin Definition 16 SIO_GPI61 25 GND 17 SIO_GPI64 26 SIO_GPI62 18 SIO_GPI67 27 SIO_GPI65 19 VCC5 28 SIO_GPI68 20 GND 29 SIO_GPI69 21 SIO_GPI60 3...

Страница 28: ...nal Co Ltd All Rights Reserved 14 NISE 90 User Manual Chapter 2 Jumpers and Connectors 9 36V DC Power Input Connector type Phoenix Contact 1x3 3 pin terminal block Connector location CN2 Pin Definition 1 GND 2 12VIN OR 24VIN 3 CH_GND ...

Страница 29: ...or Connector type 1x4 4 pin Wafer 2 54mm pitch Connector location J1 Pin Definition Pin Definition 1 GND 3 Sense 2 12V 4 Control Pin Definition Pin Definition 1 5V 5 GND 2 12V 6 GND 3 12V 7 Panel Backlight Enable 4 Panel Backlight Brightness Control 1 4 LVDS Panel Backlight Connector Connector type 1x7 JST 7 pin header 2 5mm pitch Connector location J6 1 7 ...

Страница 30: ... Connector Connector type 1x6 JST 6 pin header 2 0mm pitch Connector location J9 Pin Definition Pin Definition 1 DDC_CLK 2 DDC_DATA 3 VCC_LCD 4 LVDS_TXP0 5 LVDS_TXP3 6 LVDS_TXN0 7 LVDS_TXN3 8 VCC_LCD 9 GND 10 LVDS_TXP1 11 LVDS_CLKP 12 LVDS_TXN1 13 LVDS_CLKN 14 GND 15 GND 16 V_INV 17 LVDS_TXP2 18 V_INV 19 LVDS_TXN2 20 GND Pin Definition Pin Definition 1 5V 2 Data 3 3 Data 3 4 Data 4 5 Data 4 6 GND ...

Страница 31: ...2x7 14 pin header 2 0mm pitch Connector location JP1 Pin Definition Pin Definition 1 PWR_LED_N 2 PWR_LED_P 3 SATA_LED 4 SATA_LED_P 5 SMB_C 6 SMB_D 7 VCC3V3 8 GND 9 VCC3V3 10 GND 11 POWER BOTTOM 12 GND 13 RESET BOTTOM 14 GND 1 2 13 14 Mic in Pin Header Connector type 1x4 4 pin header 2 0mm pitch Connector location JP9 1 4 Pin Definition 1 MIC1_L 2 MIC_JD 3 GND 4 MIC1_R ...

Страница 32: ...pers and Connectors Line in Pin Header Connector type 1x4 4 pin header 2 0mm pitch Connector location JP13 Line out Pin Header Connector type 1x4 4 pin header 2 0mm pitch Connector location JP10 1 4 1 4 Pin Definition 1 FLIN_L 2 LIN_JD 3 GND 4 FLIN_R Pin Definition 1 FLOUT_L 2 LOUT_JD 3 GND 4 FLOUT_R ...

Страница 33: ...ector Connector type Standard Serial ATAII 7P 1 27mm SATA M 180 Connector location J5 1 7 Pin Definition Pin Definition 1 GND 5 SATA_RXN1 2 SATA_TXP1 6 SATA_RXP1 3 SATA_TXN1 7 GND 4 GND PoE Power Connector Connector type 2x2 4 pin header 3 5mm pitch Connector location CN1 1 2 3 4 Pin Definition 1 GND 2 GND 3 VIN Power 4 VIN Power ...

Страница 34: ... Power Connector Connector type 1x4 4 pin header 2 54mm pitch Connector location CN5 Pin Definition 1 12V 2 GND 3 GND 4 VCC5 SATA1 Connector Connector type Standard Serial ATAII 7P 1 27mm SATA M 180 Connector location J4 1 7 Pin Definition Pin Definition 1 GND 5 SATA_RXN0 2 SATA_TXP0 6 SATA_RXP0 3 SATA_TXN0 7 GND 4 GND 1 4 ...

Страница 35: ... SATA DOM Power Connector Connector type 1x2 2 pin header 2 5mm pitch Connector location J8 Pin Definition 1 VCC5 2 GND 1 2 Keyboard Mouse Pin Header Connector type 2x4 8 pin header 2 54mm pitch Connector location J2 Pin Definition Pin Definition 1 KBMSVCC 5 LKBCLK 2 KBMSVCC 6 LMCLK 3 LKBDAT 7 GND 4 LMDAT 8 GND 1 7 2 8 ...

Страница 36: ...pe 1x10 10 pin header 1 0mm pitch Connector location J16 Pin Definition Pin Definition 1 SIO_DCD 4 2 SIO_RXD4 3 SIO_TXD4 4 SIO_DTR 4 5 GND 6 SIO_DSR 4 7 SIO_RTS 4 8 SIO_CTS 4 9 SIO_RI 4 10 GND 10 1 SIM Card Connector Connector location IDE1 C3 C2 C1 C7 C6 C5 Pin Definition Pin Definition C1 UIM_PWR C2 UIM_RESET C3 UIM_CLK C5 GND C6 UIM_VPP C7 UIM_DATA ...

Страница 37: ...X2 18 GND 6 1 5V 19 N A 7 CLKREQ 20 Disable 8 UIM_PWR 21 GND 9 GND 22 PERST 10 UIM_DATA 23 PCIERX 11 REF CLK 24 3VSB 12 UIM_CLK 25 PCIERX 13 REF CLK 26 GND Pin Definition Pin Definition 27 GND 40 GND 28 1 5V 41 3VSB 29 GND 42 N A 30 SMBCLK 43 GND 31 PCIETX 44 N A 32 SMBDATA 45 N A 33 PCIETX 46 N A 34 GND 47 N A 35 GND 48 1 5V 36 USB_D 49 N A 37 GND 50 GND 38 USB_D 51 N A 39 3VSB 52 3VSB Mini PCIe ...

Страница 38: ...ON CAUTION CAUTION Prior to removing the chassis cover make sure the unit s power is off and disconnected from the power sources to prevent electric shock or system damage 1 Remove the mounting screw on the left side of the system and put them in a safe place for later use Remove screws around this side of system 2 Lift up the cover and remove it from the chassis ...

Страница 39: ...ystem Setup Installing a SATA Hard Drive 1 With the top cover removed place the SATA drive in the hard drive bracket with the mounting holes aligned Then use the provided screws to secure the drive in place 2 Connect the SATA data power cable to the connector on the hard drive SATA data power cable ...

Страница 40: ...M International Co Ltd All Rights Reserved 26 NISE 90 User Manual Chapter 3 System Setup 3 Connect the other side of SATA data power cable to the PCBA 4 Secure the cover to its original position SATA power cable SATA cable ...

Страница 41: ... All Rights Reserved 27 NISE 90 User Manual Chapter 3 System Setup Installing a Wireless LAN Module half size 1 Locate the Mini PCI Express slot on the board Mini PCI Express Slot 2 Fasten the wireless LAN module to the mini PCI express bracket ...

Страница 42: ...ser Manual Chapter 3 System Setup 4 Push the module down and then secure it with mounting screws Screw 3 Insert the Wi Fi module into the Mini PCI Express slot at a 45 degree angle until the gold plated connector on the edge of the module completely disappears inside the slot ...

Страница 43: ...hts Reserved 29 NISE 90 User Manual Chapter 3 System Setup Installing a SIM Card 1 Locate the SIM card socket on the PCBA then lift up the socket cover SIM card bracket 2 Slide the SIM card into the slot with the golden contacts facing inwards SIM card ...

Страница 44: ...Copyright 2013 NEXCOM International Co Ltd All Rights Reserved 30 NISE 90 User Manual Chapter 3 System Setup 3 Push the socket cover back to its original position ...

Страница 45: ...is configured with the values found in CMOS With easy to use pull down menus you can configure such items as Hard drives diskette drives and peripherals Video display type and display options Password protection from unauthorized use Power management features The settings made in the setup program affect how the computer performs It is important therefore first to try to understand all the setup o...

Страница 46: ... be reported in one of two different ways If the error occurs before the display device is initialized a series of beeps will be transmitted If the error occurs after the display device is initialized the screen will display the error message Powering on the computer and immediately pressing Del allows you to enter Setup Press the key to enter Setup Legends Key Function Moves the highlight left or...

Страница 47: ...up screen it indicates that there are more available fields not shown on the screen Use the up and down arrow keys to scroll through all the available fields Submenu When appears on the left of a particular field it indicates that a submenu which contains additional options are available for that field To display the submenu move the highlight to that field and press ...

Страница 48: ...em Time Access Level American Megatrends 4 6 3 7 N090 006 12 19 2011 16 46 15 00 90 512 MB DDR2 Thu 07 04 2013 07 01 23 Administrator Platform Information Displays the platform information Save Exit Advanced Chipset Boot Security Main Version 2 10 1208 Copyright C 2010 American Megatrends Inc Aptio Setup Utility Copyright C 2010 American Megatrends Inc Select Screen Select Item Enter Select Change...

Страница 49: ...er IO Configuration H W Monitor Disabled Launch Lan1 PXE OpROM Disabled Enabled Launch PXE OpROM Enables or disables the boot option for legacy network devices connected to LAN1 CPU Configuration This section is used to configure the CPU settings Advanced Version 2 10 1208 Copyright C 2010 American Megatrends Inc Aptio Setup Utility Copyright C 2010 American Megatrends Inc Select Screen Select Ite...

Страница 50: ...ed Version 2 10 1208 Copyright C 2010 American Megatrends Inc Aptio Setup Utility Copyright C 2010 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Enabled for Windows XP and Linux OS optimized for Hyper Threading Technology and Disabled for other OS OS not optimized for Hyper Threading Technolo...

Страница 51: ...ology Advanced Version 2 10 1208 Copyright C 2010 American Megatrends Inc Aptio Setup Utility Copyright C 2010 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Enable or Disable C2 and above CPU Configuration Processor Type EMT64 Processor Speed System Bus Speed Ratio Status Actual Ratio Process...

Страница 52: ...ption Access SD device in PIO mode Advanced Version 2 10 1208 Copyright C 2010 American Megatrends Inc Aptio Setup Utility Copyright C 2010 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Enables Legacy USB support AUTO option disables legacy support if no USB devices are connected DISABLE opti...

Страница 53: ...Super IO Chip Serial Port 0 Configuration Serial Port 1 Configuration Serial Port 2 Configuration Serial Port 3 Configuration IT8783F Serial Port 0 Configuration This section is used to configure serial port 0 Advanced Version 2 10 1208 Copyright C 2010 American Megatrends Inc Aptio Setup Utility Copyright C 2010 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General ...

Страница 54: ... Serial Port 0 Mode RS232 RS422 This field is used to configure the mode of serial port 0 as RS232 RS422 RS485 or RS485 AUTO Selects an optimal setting for the Super IO device RS485 RS485 AUTO Advanced Version 2 10 1208 Copyright C 2010 American Megatrends Inc Aptio Setup Utility Copyright C 2010 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous ...

Страница 55: ... Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Change the Serial Port Max Baud Rate Select 115200 bps or 921600 bps Serial Port 0 Configuration Serial Port Device Settings Change Settings Onboard Serial Port 0 Mode Onboard Serial Port Max Baud Rate Enabled IO 3F8h IRQ 4 IO 3F8h IRQ 4 RS485 AUTO 115200 bps Onboard Serial Port Max Baud Rate 115200 bps 9216...

Страница 56: ... Temperature Detects and displays the current CPU temperature System Temperature Detects and displays the current system temperature CPU FAN Speed Detects and displays the CPU fan speed Advanced Version 2 10 1208 Copyright C 2010 American Megatrends Inc Aptio Setup Utility Copyright C 2010 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values ...

Страница 57: ...h Bridge Chipset Configuration North Bridge Chipset Configuration This section is used to configure the north bridge features IGD Mode Select Save Exit Advanced Chipset Boot Security Main Version 2 10 1208 Copyright C 2010 American Megatrends Inc Aptio Setup Utility Copyright C 2010 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Opti...

Страница 58: ...nabled 256MB Select the size of the graphics memory aperture and untrusted space used by the integrated graphics device Audio Controller Enables or disables the audio controller SMBUS Controller Enables or disables the SMBus controller LAN1 and LAN2 Enables or disables LAN1 or LAN2 High Precision Timer Enables or disables the high precision event timer South Bridge Chipset Configuration This secti...

Страница 59: ... EFI Shell Quiet Boot Enabled Displays OEM logo instead of the POST messages Disabled Displays normal POST messages Fast Boot Disabled Displays normal POST messages Setup Prompt Timeout This section configures the number of seconds to wait for the setup activation key Bootup NumLock State This allows you to determine the default state of the numeric keypad By default the system boots up with NumLo...

Страница 60: ...Version 2 10 1208 Copyright C 2011 American Megatrends Inc Aptio Setup Utility Copyright C 2010 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Sets the system boot order Boot Option 1 P1 TOSHIBA MK1676G Boot Option 1 P1 TOSHIBA MK1676GSX Sets the first legacy device to boot from Disabled ...

Страница 61: ...lso press F4 to save and exit Setup Discard Changes and Exit To exit the Setup utility without saving the changes select this field then press Enter You may be prompted to confirm again before exiting You can also press ESC to exit without saving the changes Security Save Exit Advanced Chipset Boot Security Main Version 2 10 1208 Copyright C 2010 American Megatrends Inc Aptio Setup Utility Copyrig...

Страница 62: ...ges select this field then press Enter A dialog box will appear Confirm by selecting Yes to discard all changes made and restore the previously saved settings Restore Defaults To restore the BIOS to default settings select this field then press Enter A dialog box will appear Confirm by selecting Yes Save as User Defaults To use the current configurations as user default settings for the BIOS selec...

Страница 63: ...Sys 1 Chassis CHASSIS NISE90 CPU Intel Atom Processor E640 512K Cache 1 00 GHz ES Memory On board memory 1GB DDR2 Mother board NISB90 REV B A3 HDD HITACHI 250GB 7200rpm 8Mb HTS723225L9A360 SATA II FDD N A CD ROM N A CFast N A Power Supply POWER ADAPTER SPI G P FSP120 AAB N091 Add on Card N A CPU Cooler NISE90 HEATSINK System FAN N A Keyboard LEMEL B 5201 P Mouse GENIVS EASY MOUSE USB ...

Страница 64: ...stem and the loading of power supply Test Equipment PROVA CM 07 AC DC CLAMP METER Device Under Test DUT sys 1 Test Procedure 1 Power up the DUT boot into Windows XP 2 Entering standby mode HDD power down 3 Measure the power consumption and record it 4 Run Burn in test program to apply 100 full loading 5 Measure the power consumption and record it Test Data Sys 1 24V Full Loading Mode 1 42A Total 1...

Страница 65: ...1 Read Write GPIO data by I O port A04h Bit1 GPO22 Read Write GPIO data by I O port A04h Bit2 GPO23 Read Write GPIO data by I O port A04h Bit3 GPO24 Read Write GPIO data by I O port A04h Bit4 GPO25 Read Write GPIO data by I O port A04h Bit5 GPO26 Read Write GPIO data by I O port A04h Bit6 GPO27 Read Write GPIO data by I O port A04h Bit7 GPO28 Read Write GPIO data by I O port A01h Bit4 GPO29 Read W...

Страница 66: ...g Function Configuration Sequence Description Start Step1 See SetupWDT procedure Setup Watchdog Timer Environment Step2 See TimeBaseWDT procedure Initial Watchdog Timer Users can select second or minute Step3 See TimeCountWDT procedure Set Watchdog Timer Time out Value Users can set time out value Step4 See ExitSetup procedure Exit Setup Environment End ...

Страница 67: ...C mov al 02h out 2eh al mov al 02h out 2fh al ret ExitSetup ENDP SetupWDT PROC mov dx 2eh mov al 087h out dx al nop nop mov al 01h out dx al nop nop mov al 55h out dx al nop nop out dx al Write operations to special address port 2E for entering MB PnP Mode mov al 07h out 2eh al mov al 07h Select logical device for Watch Dog out 2fh al ret SetupWDT ENDP TimeBaseWDT PROC mov al 72h out 2eh al mov al...