Copyright © 2009 NEXCOM International Co., Ltd. All Rights Reserved.
70
NISE 3140, NISE 3140E, NISE 3140P2, NISE 3140P2E User Manual
Appendix A: Power Consumption
Power Consumption Measurement
Purpose
The purpose of the power consumption test is to verify the power dissipa-
tion of the system and the load of the power supply.
Test Equipment
PROVA CM-07 AC/DC CLAMP METER
Device Under Test
DUT: Sys #1 / Sys #2
Test Procedure
1. Power up the DUT then boot Windows XP.
2. Enter the standby mode (HDD power down).
3. Measure the power consumption and record it.
4. Run the Burn-in test program to apply 100% full loading.
5. Measure the power consumption and record it.
Test Data
Sys #1
Sys #2
+24V
+24V
Full-Loading Mode
1.85A
2.35A
Total
43.2W
56.4W
Standby Mode
0.8A
0.78A
Total
19.2W
18.72W