background image

NEXCOM International Co., Ltd.

NEXCOM International Co., Ltd.

Published July 2020

www.nexcom.com

Intelligent Platform & Services Business Unit

Edge Computing System 
Neu-X300 Series

User Manual

Содержание Neu-X300-H310

Страница 1: ...NEXCOM International Co Ltd NEXCOM International Co Ltd Published July 2020 www nexcom com Intelligent Platform Services Business Unit Edge Computing System Neu X300 Series User Manual ...

Страница 2: ...dware Specifications 2 Physical Features 3 Neu X300 Q370 Front Panel 3 Neu X300 Q370 Rear Panel 3 Neu X300 H310 Front Panel 4 Neu X300 H310 Rear Panel 4 Mechanical Dimensions 5 Neu X300 Q370 5 Neu X300 H310 6 Chapter 2 Jumpers and Connectors Before You Begin 7 Precautions 7 Jumper Settings 8 Locations of the Jumpers and Connectors for the Neu X300 Series 9 Top View 9 Bottom View 10 Jumpers DIP Swi...

Страница 3: ... pin Connector 24 SATA Connector 25 SATA Power Connector 25 System Power Button Connector 26 GPIO Connector 26 M 2 Connector M Key 27 M 2 Connector E Key 28 PCIe x16 Slot 29 Chapter 3 System Setup Removing the Bottom Cover from the Chassis 31 Installing an M 2 M Key SSD Module M Key 2280 32 Installing a SO DIMM Memory Module 34 Installing a Wi Fi Module M 2 E Key Slot 35 Installing a CPU 38 Wall M...

Страница 4: ...rk of NEXCOM International Co Ltd All other product names mentioned herein are registered trademarks of their respective owners Regulatory Compliance Statements This section provides the FCC compliance statement for Class A devices and describes how to keep the system CE compliant Declaration of Conformity FCC This equipment has been tested and verified to comply with the limits for a Class A digi...

Страница 5: ...m and Polybrominated diphenyl Ethers PBDE 0 1 or 1 000ppm In order to meet the RoHS compliant directives NEXCOM has established an engineering and manufacturing task force to implement the introduction of green products The task force will ensure that we follow the standard NEXCOM development procedure and that all the new RoHS components and new manufacturing processes maintain the highest indust...

Страница 6: ...esponsible for the safe packaging of defective products making sure it is durable enough to be resistant against further damage and deterioration during transportation In case of damages occurred during transportation the repair is treated as Out of Warranty Any products returned by NEXCOM to other locations besides the customers site will bear an extra charge and will be billed to the customer Re...

Страница 7: ...is and power supply are inconsistent with these instructions or the instructions for accessory modules contact the supplier to find out how you can ensure that your computer meets safety and regulatory requirements Cautions Electrostatic discharge ESD can damage system components Do the described procedures only at an ESD workstation If no such station is available you can provide some ESD protect...

Страница 8: ...mage the soft metal or plastic parts of the connectors Safety Information Before installing and using the device note the following precautions Read all instructions carefully Do not place the unit on an unstable surface cart or stand Follow all warnings and cautions in this manual When replacing parts ensure that your service technician uses parts specified by the manufacturer Avoid using the sys...

Страница 9: ...oltage 12 Never pour any liquid into an opening This may cause fire or electrical shock 13 Never open the equipment For safety reasons the equipment should be opened only by qualified service personnel 14 If one of the following situations arises get the equipment checked by service personnel a The power cord or plug is damaged b Liquid has penetrated into the equipment c The equipment has been ex...

Страница 10: ...mation of the installed software operating system version application software etc A complete description of the problem The exact wordings of the error messages Warning 1 Handling the unit carry the unit with both hands and handle it with care 2 Maintenance to keep the unit clean use only approved cleaning products or clean with a dry cloth Conventions Used in this Manual Warning Information abou...

Страница 11: ...aichung Office 16F No 250 Sec 2 Chongde Rd Beitun Dist Taichung City 406 R O C Tel 886 4 2249 1179 Fax 886 4 2249 1172 Email sales nexcom com tw www nexcom com tw NexCOBOT Taiwan Co Ltd 13F No 916 Chung Cheng Rd ZhongHe District New Taipei City 23586 Taiwan R O C Tel 886 2 8226 7796 Fax 886 2 8226 7792 Email sales nexcom com tw www nexcom com tw GreenBase Technology Corp 13F No 922 Chung Cheng Rd ...

Страница 12: ...yinmingzun Plaza Bldg 1 No 609 Yunlin East Rd Shanghai 200062 China Tel 86 21 5278 5868 Fax 86 21 3251 6358 Email sales nexcom cn www nexcom cn NEXCOM Surveillance Technology Corp Floor 5 Building C ZhenHan Industrial Zone GanKeng Community Buji Street LongGang District ShenZhen 518112 China Tel 86 755 8364 7768 Fax 86 755 8364 7738 Email steveyang nexcom com tw www nexcom cn NEXCOM United System ...

Страница 13: ...ng table Item Name Qty 1 Neu X300 System 1 2 Power Adapter 1 Optional Accessories Item Part Number Name Description 1 5060200503X00 Thermal Pad For M 2 Thermal Pad E LIN 65x20x1 0mm K 1 4W mk S3S 2 5060200082X00 Thermal Pad For CPU Thermal Pad NDiS B533 VER A EAPUS 25x25x0 2mm 3 7400096006X00 Power Adapter Power Adapter FSP FSP096 AHBN2 N090001 96W DC12V 8A DC Plug 4 Pin Power Molding Type 4 74000...

Страница 14: ...ing Information The following below provides ordering information for Neu X300 Neu X300 Q370 PCB Ver B P N 10W10X30000X4 8th generation Intel Core processor slim and fanless system with PCH Q370 Neu X300 H370 PCB Ver B P N 10W10X30001X4 8th generation Intel Core processor slim and fanless system with PCH H310 ...

Страница 15: ... 1 Product Introduction Chapter 1 Product Introduction Key Features 8th generation Intel Core socket type processor HDMI 2 0 resolution 4K 60Hz Storage M 2 M Key 2280 Support Intel vPro technology Dual DDR4 SO DIMM Onboard TPM 2 0 IC Fanless design Neu X300 Series Overview Neu X300 Q370 Neu X300 H310 ...

Страница 16: ...les 4 x USB 3 0 3 x HDMI 2 0 only 2 x HDMI 2 0 for H310 1 x RS232 422 485 COM port 2 x RJ45 with LEDs for Gigabit LAN 1 x 12V DC input 4 pin DC jack 1 x Audio out Internal I O 2 x RS232 COM port connectors 4 x USB 2 0 pin header 1 x PCIe x16 slot not supported on H310 1 x SATA connector 1 x GPIO Expansion 1 x M 2 2230 connector supports Wi Fi module Storage 1 x M 2 M Key 2280 SSD with SATA PCIe x4...

Страница 17: ...ts Reserved 3 Neu X300 Series User Manual Chapter 1 Product Introduction Physical Features Neu X300 Q370 Front Panel Neu X300 Q370 Rear Panel Storage LED Antenna Hole Antenna Hole Line out USB 3 0 HDMI1 HDMI2 HDMI3 LAN1 LAN2 Power Button COM 1 DC Input ...

Страница 18: ...Ltd All Rights Reserved 4 Neu X300 Series User Manual Chapter 1 Product Introduction Neu X300 H310 Front Panel Neu X300 H310 Rear Panel Storage LED Antenna Hole Antenna Hole Line out USB 3 0 HDMI1 HDMI2 LAN1 LAN2 Power Button COM 1 DC Input ...

Страница 19: ...Copyright 2020 NEXCOM International Co Ltd All Rights Reserved 5 Neu X300 Series User Manual Chapter 1 Product Introduction Mechanical Dimensions Neu X300 Q370 200 201 215 190 54 4 ...

Страница 20: ...Copyright 2020 NEXCOM International Co Ltd All Rights Reserved 6 Neu X300 Series User Manual Chapter 1 Product Introduction Neu X300 H310 200 201 215 190 54 4 ...

Страница 21: ...ourself before touching any internal components by touching a metal object Static electricity can damage many of the electronic components Humid environments tend to have less static electricity than dry environments A grounding strap is warranted whenever danger of static electricity exists Precautions Computer components and electronic circuit boards can be damaged by discharges of static electr...

Страница 22: ... the jumpers ensure that the jumper caps are placed on the correct pins When the jumper cap is placed on both pins the jumper is short If you remove the jumper cap or place the jumper cap on just one pin the jumper is open Refer to the illustrations below for examples of what the 2 pin and 3 pin jumpers look like when they are short on and open off Two Pin Jumpers Open Left and Short Right Three P...

Страница 23: ...2 3 7 H2 H10 H11 H1 H7 H6 H5 H3 B82 B2 B81 A82 A81 A1 B1 A2 MADE IN TAIWAN 4BW0X300B1X10 VER B X300 E 1 9 10 LGA PCH DIMMB DIMMA HDMI2 Only for NEU X300 Q370 HDMI1 HDMI3 USB3_P34 USB3_P12 LAN2 J4 J5 J6 SATA_PWR J7 12v only J3 DEBUG SATA6G LINE_OUT MIC COM1 COM3 COM2 GPIO FAN1 FAN2 J2 J1 LVDS CN1 INV W_USB DC_PWR BATTERY ATX_AT CLRTC LVDS_PWR BLT_PWM PCIEX16 SW1 RESET M2E ME_LOCK LAN1 LED_CON Locat...

Страница 24: ...Copyright 2020 NEXCOM International Co Ltd All Rights Reserved 10 Neu X300 Series User Manual Chapter 2 Jumpers and Connectors 4BW0X300B1X10 MADE IN TAIWAN X300 VER B 1 33 75 74 1 M2M Bottom View ...

Страница 25: ... Jumpers DIP Switches AT ATX Mode Select Connector type 1x3 3 pin header 2 54mm pitch Connector location ATX_AT Clear CMOS Connector type 1x3 3 pin header 2 54mm pitch Connector location CLRTC Pin Settings 1 2 On ATX Mode 2 3 On AT Mode 1 2 On default Pin Settings 1 2 On Normal 2 3 On Clear CMOS 1 2 On default 1 3 1 3 1 1 3 3 ...

Страница 26: ... LVDS Panel Voltage Select Connector type 1x3 3 pin header 2 54mm pitch Connector location LVDS_PWR Backlight Control Voltage Select Dimming Connector type 1x3 3 pin header 2 0mm pitch Connector location BLT_PWM Pin Settings 1 2 On 3 3V 2 3 On 5V 1 2 On default Pin Settings 1 2 On 3 3V 2 3 On 5V 1 2 On default 1 3 1 3 1 1 3 3 ...

Страница 27: ...ights Reserved 13 Neu X300 Series User Manual Chapter 2 Jumpers and Connectors ME Flash Descriptor Security Override Connector type 1x3 3 pin header 2 0mm pitch Connector location ME_LOCK Pin Settings 1 2 On Lock 2 3 On Unlock 1 2 On default 1 3 1 3 ...

Страница 28: ... OFF OFF 1280 x 1024 6 bit Single Port 0100 ON OFF ON ON 1280 x 800 6 bit Single Port 0101 ON OFF ON OFF 1280 x 960 6 bit Single Port 0110 ON OFF OFF ON 1280 x 1024 8 bit Dual Port 0111 ON OFF OFF OFF 1366 x 768 6 bit Single Port 1000 OFF ON ON ON 1366 x 768 8 bit Single Port 1001 OFF ON ON OFF 1440 x 900 8 bit Dual Port 1010 OFF ON OFF ON 1400 x 1050 8 bit Dual Port 1011 OFF ON OFF OFF 1600 x 900...

Страница 29: ...T 6 CT 7 MDI_2P 8 MDI_2N 9 MDI_3P 10 MDI_3N 11 3VSB 12 ACTLED 13 LINK100 14 LINK1000 ACT LINK 8 1 Act Status Flashing Yellow Data activity Off No activity Link Status Steady Green 1G network link Steady Orange 100Mbps network link Off 10Mbps or no link HDMI1 HDMI2 and HDMI3 Port HDMI3 Only for Q370 Connector type HDMI port Connector location HDMI1 HDMI2 and HDMI3 Pin Definition Pin Definition 1 TX...

Страница 30: ... GND 5 USB3_RX2N 6 USB3_RX2P 7 GND 8 USB3_TX2N 9 USB3_TX2P 10 5V 11 USB2_1N 12 USB2_1P 13 GND 14 USB3_RX1N 15 USB3_RX1P 16 GND 17 USB3_TX1N 18 USB3_TX1P 9 1 10 13 14 18 4 5 USB 3 0 Ports Connector type Dual USB 3 0 port Connector location USB3_P12 and USB3_P34 DC Power Input 12V Only Connector location CN1 Pin Definition Pin Definition 1 12VSUS 2 12VSUS 3 GND 4 GND 5 CGND 1 2 3 4 5 ...

Страница 31: ...hts Reserved 17 Neu X300 Series User Manual Chapter 2 Jumpers and Connectors COM1 DB9 Male Connector Connector type DB 9 port 9 pin D Sub Connector location COM1 1 6 5 9 Pin Definition Pin Definition 1 DCD 2 RXD 3 TXD 4 DTR 5 GND 6 DSR 7 RTS 8 CTS 9 RI ...

Страница 32: ...nal Connectors LVDS Inverter Connector Connector type 1x7 7 pin header JST 2 5mm pitch Connector location INV Pin Definition Pin Definition 1 5V 2 12V 3 12V 4 Backlight Control 5 GND 6 GND 7 Backlight Enable 7 1 System Reset Header Connector type 1x2 2 pin header 2 54mm pitch Connector location RESET Pin Definition 1 RESET 2 GND 1 2 ...

Страница 33: ...D Connector Connector type 1x5 5 pin header JST 2 0mm pitch Connector location LED_CON Pin Definition Pin Definition 1 HDD_LED 2 HDD_LED 3 GND 4 Standby LED 5 PWR LED 5 1 1 4 Pin Definition Pin Definition 1 LOUT_L 2 GND 3 LOUT_JD 4 LOUT_R Line out Connector Connector type 1x4 4 pin header 1 25mm pitch Connector location LINE_OUT ...

Страница 34: ... Jumpers and Connectors 1 4 Pin Definition Pin Definition 1 MIC_L 2 GND 3 MIC_JD 4 MIC_R Mic in Connector Connector type 1x4 4 pin header 1 25mm pitch Connector location MIC System Power Button Header Connector type 1x2 2 pin header JST 2 0mm pitch Connector location J7 Pin Definition 1 PWRBTN 2 GND 1 2 ...

Страница 35: ...type 1x4 4 pin header 2 54mm pitch Connector location FAN1 and FAN2 Pin Definition Pin Definition 1 GND 2 12V 3 FAN SPEED DETECT 4 FAN SPEED CONTROL Debug Port LPC Bus Connector Connector type 1x10 10 pin header 1 0mm pitch Connector location DEBUG Pin Definition Pin Definition 1 3V 2 SERIRQ 3 LAD0 4 LAD1 5 LAD2 6 LAD3 7 LFRAME 8 24MHZ 9 PLTRST 10 GND 1 10 ...

Страница 36: ...onnectors COM Port Connectors Connector type 1x9 9 pin header 1 0mm pitch Connector location COM1 COM2 and COM3 Pin Definition Pin Definition 1 DCD 2 RXD 3 TXD 4 DTR 5 GND 6 DSR 7 RTS 8 CTS 9 RI 1 9 Battery Connector Connector type 1x2 2 pin header 1 25mm pitch Connector location BATTERY Pin Definition 1 BAT 2 GND 1 2 ...

Страница 37: ..._D3 11 LVDS1_D2 12 LVDS1_D2 13 LVDS1_D1 14 LVDS1_D1 15 LVDS1_D0 16 LVDS1_D0 17 GND 18 V_PANEL 3 3V or 5V 19 V_PANEL 3 3V or 5V 20 V_PANEL 3 3V or 5V 21 GND 22 3 3V 23 GND 24 GND 25 GND 26 LVDS0_CLK 27 LVDS0_CLK 28 GND 29 GND 30 GND 31 SMBUS_CLK 32 Backlight Enable 33 Backlight Control 34 LVDS1_CLK 35 LVDS1_CLK 36 12V 37 12V 38 12V 39 NC 40 SMBUS_DAT 1 Internal USB 2 0 Connectors Connector type 2x5...

Страница 38: ... Connectors USB Touch Connector type 1x6 6 pin header JST 2 5mm pitch Connector location W_USB ATX 4 pin Connector Connector type 1x4 4 pin header Connector location DC_PWR 6 1 Pin Definition Pin Definition 1 5V 2 USB1N 3 USB1P 4 USB2N 5 USB2P 6 GND Pin Definition Pin Definition 1 12VSUS 2 12VSUS 3 GND 4 GND 1 2 3 4 ...

Страница 39: ...nnector Connector type Standard Serial ATA 7P 1 27mm SATA M 180 Connector location SATA6G 1 7 Pin Definition Pin Definition 1 GND 2 SATA_TXP 3 SATA_TXN 4 GND 5 SATA_RXN 6 SATA_RXP 7 GND SATA Power Connector Connector type 1x4 4 pin header 2 5mm pitch Connector location SATA_PWR 1 4 Pin Definition Pin Definition 1 5V 2 GND 3 GND 4 12V ...

Страница 40: ...tion 1 5V 2 GND 3 PWRBTN 4 GND System Power Button Connector Connector type 1x4 4 pin header 2 0mm pitch Connector location J6 1 4 GPIO Connector Connector type 2x5 10 pin header 2 0mm pitch Connector location GPIO Pin Definition Pin Definition 1 5V 2 GND 3 SIO_GP10 4 SIO_GP11 5 SIO_GP12 6 SIO_GP13 7 SIO_GP14 8 SIO_GP15 9 SIO_GP16 10 SIO_GP17 1 9 2 10 ...

Страница 41: ... 3VSB 15 GND 16 3VSB 17 PCIE3_RXN 18 3VSB 19 PCIE3_RXP 20 NC 21 GND 22 NC 23 PCIE3_RXN 24 NC 25 PCIE3_RXP 26 NC 27 GND 28 NC 29 PCIE2_RXN 30 NC 31 PCIE2_RXP 32 NC 33 GND 34 NC 35 PCIE2_RXN 36 NC 37 PCIE2_RXP 38 DEVSLP Pin Definition Pin Definition 39 GND 40 NC 41 SATA_RXP PCIE1_RXP 42 NC 43 SATA_RXN PCIE1_RXN 44 NC 45 GND 46 NC 47 SATA_TXN PCIE1_TXN 48 NC 49 SATA_TXP PCIE1_TXP 50 RESET 51 GND 52 C...

Страница 42: ... NC 10 NC 11 NC 12 NC 13 NC 14 NC 15 NC 16 NC 17 NC 18 NC 19 NC 20 NC 21 NC 22 NC 23 NC 32 NC 33 GND 34 NC 35 PCIE_TXP 36 NC 37 PCIE_TXN 38 NC 39 GND 40 NC 41 PCIE_RXP 42 NC Pin Definition Pin Definition 43 PCIE_RXN 44 NC 45 GND 46 NC 47 CLK_PCIEP 48 NC 49 CLK_PCIEN 50 SUSCLK 51 GND 52 PLTRST 53 CLKREQ 54 BT_DISABLE 55 WAKE 56 WIFI_DISABLE 57 GND 58 NC 59 NC 60 NC 61 NC 62 NC 63 GND 64 NC 65 NC 66...

Страница 43: ...8 NC B8 3 3V A9 3 3V B9 NC A10 3 3V B10 3VSUS A11 PCIRST B11 WAKE A12 GND B12 NC A13 CLK_PCIEP B13 GND A14 CLK_PCIEN B14 TXP0 A15 GND B15 TXN0 A16 RXP0 B16 GND A17 RXN0 B17 PCIEX16_PRSNT A18 GND B18 GND Pin Definition Pin Definition A19 NC B19 TXP1 A20 GND B20 TXN1 A21 RXP1 B21 GND A22 RXN1 B22 GND A23 GND B23 TXP2 A24 GND B24 TXN2 A25 RXP2 B25 GND A26 RXN2 B26 GND A27 GND B27 TXP3 A28 GND B28 TXN...

Страница 44: ...A51 GND B51 TXN8 A52 RXP8 B52 GND A53 RXN8 B53 GND A54 GND B54 TXP9 A55 GND B55 TXN9 A56 RXP9 B56 GND A57 RXN9 B57 GND A58 GND B58 TXP10 A59 GND B59 TXN10 Pin Definition Pin Definition A60 RXP10 B60 GND A61 RXN10 B61 GND A62 GND B62 TXP11 A63 GND B63 TXN11 A64 RXP11 B64 GND A65 RXN11 B65 GND A66 GND B66 TXP12 A67 GND B67 TXN12 A68 RXP12 B68 GND A69 RXN12 B69 GND A70 GND B70 TXP13 A71 GND B71 TXN13...

Страница 45: ...om Cover from the Chassis 1 The fifteen screws on the front rear and bottom are used to secure the cover to the chassis Remove these screws and put them in a safe place for later use CAUTION CAUTION CAUTION Prior to removing the chassis cover make sure the unit s power is off and disconnected from the power sources to prevent electric shock or system damage ...

Страница 46: ... Series User Manual Chapter 3 System Setup Installing an M 2 M Key SSD Module M Key 2280 1 On the bottom of the system loosen the screws on the bottom cover and then remove the cover from the chassis 2 Remove the screw on the standoff and put it in a safe place for later use ...

Страница 47: ...anual Chapter 3 System Setup 3 Insert the M 2 SSD module into the M 2 slot at a 45 degree angle until the gold plated connector on the edge of the module completely disappears With the module fully inserted tighten the screw removed earlier into the mounting hole on the module to secure it ...

Страница 48: ...emoved install a memory module in the SO DIMM socket Insert the module into the socket at an approximately 30 degree angle Push the module down until the clips on both sides of the socket lock into position The gold plated connector on the edge of the module will almost completely disappear inside the socket Installing a SO DIMM Memory Module ...

Страница 49: ... With the bottom cover removed insert the Wi Fi module into the slot at a 45 degree angle until the gold plated connector on the edge of the module completely disappears inside the slot Installing a Wi Fi Module M 2 E Key Slot 2 Push the module down and tighten a screw into the mounting hole on the module to secure it ...

Страница 50: ...User Manual Chapter 3 System Setup 3 Attach the RF cable onto the Wi Fi module and remove the antenna hole cover on the rear panel Then insert the antenna jack end of the cable through the antenna hole 4 Insert the 2 rings ring 1 then ring 2 into the Wi Fi antenna jacks Ring 2 Ring 1 ...

Страница 51: ...Copyright 2020 NEXCOM International Co Ltd All Rights Reserved 37 Neu X300 Series User Manual Chapter 3 System Setup 5 Connect the external antenna to the Wi Fi antenna jack ...

Страница 52: ...hapter 3 System Setup Installing a CPU 1 Loosen the four mounting screws on the heat sink then remove it to access the CPU socket Load Lever 2 Unlock the socket by pushing the load lever down moving it sideways until it is released from the retention tab then lift the load lever up Retention Tab ...

Страница 53: ...ll at the same time fit into the socket s alignment key Alignment key Alignment key Handle the CPU by its edges and avoid touching the pins The CPU will fit in only one orientation and can easily be inserted without exerting any force CAUTION CAUTION CAUTION 4 Close the load plate and then hook the load lever under the retention tab Do not force the CPU into the socket Forcing the CPU into the soc...

Страница 54: ...Copyright 2020 NEXCOM International Co Ltd All Rights Reserved 40 Neu X300 Series User Manual Chapter 3 System Setup 5 Reinstall the heat sink with the four mounting screws removed earlier ...

Страница 55: ...des of the bottom surface 2 Secure the brackets to the system by inserting two retention screws into each bracket Wall Mounting Instructions Wall Mount Bracket Specification of the wall mount screw Round Head Screw Long Fei P6 32TX8L_w Spring Flat Washer 3 Drill holes in the intended installation surface 4 Align the mounting holes on the sides of the mounting brackets with the predrilled holes on ...

Страница 56: ... system is configured with the values found in CMOS With easy to use pull down menus you can configure such items as Hard drives diskette drives and peripherals Video display type and display options Password protection from unauthorized use Power management features The settings made in the setup program affect how the computer performs It is important therefore first to try to understand all the...

Страница 57: ...will be reported in one of two different ways If the error occurs before the display device is initialized a series of beeps will be transmitted If the error occurs after the display device is initialized the screen will display the error message Powering on the computer and immediately pressing Del allows you to enter Setup Press the key to enter Setup Legends Key Function Moves the highlight lef...

Страница 58: ... setup screen it indicates that there are more available fields not shown on the screen Use the up and down arrow keys to scroll through all the available fields Submenu When appears on the left of a particular field it indicates that a submenu which contains additional options are available for that field To display the submenu move the highlight to that field and press ...

Страница 59: ... DT Intel R Core TM i7 8700T CPU 2 40GHz 2400 MHz 0x906EA U0 LGA1151 6Core s 12Thread s B4 GT2 0x3E92 16384 MB 2667 MHz CNL PCH H Q370 B0 Save Exit Advanced Chipset Security Boot Main Version 2 20 1275 Copyright C 2020 American Megatrends Inc Aptio Setup Utility Copyright C 2020 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimize...

Страница 60: ...work Stack Configuration CPU Configuration This section is used to view CPU status and configure CPU parameters Intel VMX Virtualization Technology When this field is set to Enabled the VMM can utilize the additional hardware capabilities provided by Vanderpool Technology Active Processor Cores Select the number of cores to enable in each processor package Hyper threading Enables or disables hyper...

Страница 61: ...C 2020 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Enables or Disables BIOS support for security device O S will not show Security Device TCG EFI protocol and INT1A interface will not be available TPM20 Device Found Firmware Version Vendor Security Device Support Active PCR banks Available ...

Страница 62: ... devices with the default set to TPM 2 0 devices if not found and TPM 1 2 devices will be enumerated Disable Block Sid Enables or disables the option to allow SID authentication in TCG storage device ACPI Settings This section is used to configure ACPI settings Exit Advanced Chipset PCIPnP Security Main Version 2 20 1275 Copyright C 2020 American Megatrends Inc Aptio Setup Utility Copyright C 2020...

Страница 63: ...Super IO Chip Serial Port 1 Configuration Serial Port 2 Configuration Serial Port 3 Configuration Serial Port 4 Configuration NCT6116D Serial Port 1 Configuration This section is used to configure serial port 1 Serial Port Enables or disables the serial port Onboard Serial Port Mode Select this to change the serial port mode to RS232 RS422 RS485 No Terminator or RS485 With Terminator Advanced Vers...

Страница 64: ...Copyright C 2020 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Enable or Disable Serial Port COM Serial Port 2 Configuration Serial Port Device Settings Enabled IO 2F8h IRQ 3 Advanced Version 2 20 1275 Copyright C 2020 American Megatrends Inc Aptio Setup Utility Copyright C 2020 American Mega...

Страница 65: ...an Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Smart Fan function setting Pc Health Status CPU temperature System temperature Fan1 Speed Fan2 Speed VCORE VDDQ 5V 3 3V Smart Fan Function 34 5 c 37 0 c N A N A 0 880 V 1 236 V 5 095 V 3 416 V Serial Port 4 Configuration This section is used to configur...

Страница 66: ...Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Smart Fan 1 Mode Select Pc Health Status Fan 1 Setting Smart Fan 1 Mode Manual PWM Setting Fan 2 Setting Smart Fan 2 Mode Manual PWM Setting Manual mode 62 5 Manual mode 62 5 Advanced Boot Security Save Exit Main Version 2 20 1275 Copyright C 2020 American Megatrends Inc Aptio Setup Utility Copyright C 2020 American...

Страница 67: ...space 1 Device Self Test Self Test Option Self Test Action Run Device Self Test Short Device Selftest Result Extended Device Selftest Result 00 04 00 00 480GB PCIe Drive 480 1 GB 1BCD 5008 Size 480 1 GB Short Controller Only Test Not Available Not Available NVMe Device 480GB PCIe Drive Self Test Option Configures the method used for self test Short Short option will take couple of minutes to compl...

Страница 68: ... network stack Advanced Version 2 20 1275 Copyright C 2020 American Megatrends Inc Aptio Setup Utility Copyright C 2020 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Enable Disable UEFI network stack Network Stack Disabled Network Stack Enables or disables UEFI network stack ...

Страница 69: ...atrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Graphics Configuration System Agent SA Configuration VT d Graphics Configuration PEG Port Configuration VT d Supported Enabled Graphics Configuration Enters the Graphics Configuration submenu PEG Port Configuration Enters the PEG Port Configuration submenu VT...

Страница 70: ... ESC Exit Select which of HDMI PEG Graphics device should be Primary Display Graphics Configuration Primary Display Auto Enable Root Port Enables or disables the root port Max Link Speed Configures the maximum link speed of the PEG device Version 2 20 1275 Copyright C 2020 American Megatrends Inc Aptio Setup Utility Copyright C 2020 American Megatrends Inc Select Screen Select Item Enter Select Ch...

Страница 71: ...p F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit SATA Device Options Settings PCH IO Configuration SATA And RST Configuration HD Audio Configuration USB Power State in S5 Current Power Mode State After G3 ON ATX Mode Always On SATA And RST Configuration Save Exit Advanced Chipset Security Boot Main Version 2 20 1275 Copyright C 2020 American Megatrends Inc Aptio Setup Utility Copyr...

Страница 72: ...will be unconditionally enabled Security Administrator Password Select this to reconfigure the administrator s password User Password Select this to reconfigure the user s password Save Exit Advanced Chipset Security Boot Main Version 2 20 1275 Copyright C 2020 American Megatrends Inc Aptio Setup Utility Copyright C 2020 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 ...

Страница 73: ...m reset and while the System is in Setup mode System Mode Secure Boot Secure Boot Mode Restore Factory Keys Reset To Setup Mode Key Management Vendor Keys Factory Key Provision Restore Factory Keys Reset To Setup Mode Export Secure Boot variables Enroll Efi Image Device Guard Ready Remove UEFI CA from DB Restore DB defaults Secure Boot variable Size Keys Key Source Platform Key PK 0 0 No Keys Key ...

Страница 74: ... Save Exit ESC Exit Number of seconds to wait for setup activation key 65535 0xFFFF means indefinite waiting Boot Configuration Setup Prompt Timeout Bootup NumLock State Boot Option Priorities Boot Option 1 Off UEFI Built in EFI Shell 1 Save Exit Advanced Chipset Security Boot Main Version 2 20 1275 Copyright C 2020 American Megatrends Inc Aptio Setup Utility Copyright C 2020 American Megatrends I...

Отзывы: