Nexans GigaSwitch 641 Desk Скачать руководство пользователя страница 4

General

Page 4

Telephone helpdesk: 

+49 (0) 2166 27 2220

Application

The new Nexans "GigaSwitch 641 Desk" is our next generation pure Gigabit Desktop switch system for FTTO applications.

Easy Installation

The very compact design of this switch allows easy integration on the desktop. Nexans is also providing the comfortable
kits for wall mounting of switch and external power supply.

Power over Ethernet - plus Capability

The Switch provide the PoE plus High Power up to 30 Watts on each of 4 users ports. This function allows to supply the
Ethernet devices with higher demands on consumption. The new Nexans Switch could provide up to 120 Watts for such
services.

10/100/1000 Mbps user ports with Energy Efficient Ethernet (EEE)

The key feature of the new GigaSwitch series is support for Energy Efficient Ethernet (EEE) which is standardized as the
802.3az standard. All Twisted Pair Ports are Energy Efficient Ethernet compliant and automatically shutting down the ports
in case of shut down or reducing of Ethernet traffic. The Network can benefit from lower power consumption, which redu-
ces energy costs and lowers overall operating costs for IT equipment.

Memory Card

The optional Memory Card always stores the complete and most actual configuration of the switch automatically. In case
of a system exchange you just need to take out the Memory Card of the old switch and insert it into the new switch. During
the boot process the new switch will then take over the old configuration from the Memory Card. Furthermore each Memory
Card has got its own MAC Address. As soon as a Memory Card is inserted into a system, the active MAC address is the
MAC Address of the Memory Card, i.e. there is no need to change routing tables in case of a system exchange!

Features

General

• 6 port switch with up to 2 uplinks 
• 10/100/1000 Mbps Ethernet/Fast 

Ethernet/Gigabit Ethernet accor-
ding IEEE802.3/-u/-z/-ab

• Store and Forward Switch,

self learning (Layer-2 switch)

• Support of Jumboframes

(10240 bytes)

Memory Card

(optional)

• Memory Card with MAC-Address

Power Supply

• Wide Range Power Supply

46 ... 57 VDC (typ. 48 VDC)

• 3 pin Terminal Block

up to 2.5 mm² (+) (-) (FPE)

Uplink Interfaces

• 2 uplinks (SFP and TP-RJ45)
• 1x 100/1000 Mbps

SFP Vario-Interface

• 1x 10/100/1000 Mbps TP 

Interface

• SFP interface with threshold

alarm function (Syslog,
SNMP-Trap etc.)

Twisted Pair User Interfaces 

• 4 female RJ45 user / terminal 

interfaces

• Interfaces according to:

- IEEE802.3 10BASE-T or
- IEEE802.3u 100BASE-TX or
- IEEE802.3ab 1000BASE-T

• MDI/MDI-X Auto-Crossover and 

Auto-Polarity

• 10/100/1000 Mbps
• Good an easy accessible unlock-

ing of the twisted pair patch 
cables

• Support of Energy Efficient (EEE)

according to IEEE802.3az

Power over Ethernet (PSE)

• 4x Power over Ethernet (PSE) 

according to IEEE802.3at
(Mode A)

• Full galvanic isolation between

PoE voltage and switch electronics

Mechanics

• Smallest Size

(148 mm x 24 mm x 118mm)

• Fanless system

Management

• Supports Web / Telnet / SSH / 

SNMP User Interfaces 

• Extensive Security Management 

incl. different authentications 
(RADIUS, IEEE802.1x, SCP etc.)

• Rapid Spanning Tree
• Extensive management features 

like DHCP, VLAN, Port-Prioritization,
IEEE802.1p, IPv4, IPv6, 
IEEE802.1Q Tagging, QoS etc.

• Different alarm and signalling 

traps for service and security
support

• Up to 8 different categorisable 

trap destinations 

• Cisco Interoperability

Temperature range

• 0°C ... +40°C (Operation)

Warranty

• 2 years

Содержание GigaSwitch 641 Desk

Страница 1: ...Technical Documentation GigaSwitch 641 Desk SFP I 48V ES3 ...

Страница 2: ...Page 2 Telephone helpdesk 49 0 2166 27 2220 ...

Страница 3: ...12 Functional parameters Page 12 48 VDC and PoE Power Supply Page 12 SFP Interfaces Page 12 Electrical interfaces Twisted Pair Page 12 Dimensions Page 13 Management Functions Access Control Authentication Management Page 14 WEB HTTP HTTPS Access Page 14 Telnet SSH and V 24 Console Page 14 SNMP Access SNMP Traps and Syslog Messages Page 14 Portsecurity Page 14 VLAN Support Trunking Page 14 Prioriti...

Страница 4: ...a Memory Card is inserted into a system the active MAC address is the MAC Address of the Memory Card i e there is no need to change routing tables in case of a system exchange Features General 6 port switch with up to 2 uplinks 10 100 1000 Mbps Ethernet Fast Ethernet Gigabit Ethernet accor ding IEEE802 3 u z ab Store and Forward Switch self learning Layer 2 switch Support of Jumboframes 10240 byte...

Страница 5: ... view 3 pin Terminal Block FPE SFP Interface Slot Port 5 TP Uplink Interface Port 6 Status LED Memory Card Status LEDs Power over Ethernet Status LEDs Management Status LEDs Link Activity Memory Card Interface bottom side User Interfaces Port 1 4 54 VDC Kensington Lock ...

Страница 6: ...meters The electrical parameters are specified in the respective Technical Data The power consumption value on the primary side is indicated on the type label and or in the Technical Data Electromagnetic compatibility The installed unit fulfils the requirements of the European standards EN 55022 Temperature The unit has been designed for indoor use and can be operated at ambient temperatures from ...

Страница 7: ... the unit if the unit has been stored or transported at low temperatures and subsequently taken into a warm room In order to avoid any damage please wait till any moisture condensation has vanished from the unit s surface before switching the unit on The unit is operational only after it has reached the guaranteed operating temperature range see Technical Data The same applies also to prior storag...

Страница 8: ...nd has a valid IP address c blinks green when switch is up but has not yet received a valid IP address d lights red when switch is up with fixed IP address MC multicolor a lights blue when switch is booting and configuration from memory card is loading b lights green when switch is up and the current flash configuration is mirrored to the memory card Link 1 green a lights up permanently when the l...

Страница 9: ...ort using the fixed IP address 172 23 44 111 Moreover the IP Link VLAN trunking and Portsecurity settings can be made without these settings taking immediate effect Only after a Booting with Flash Configuration the stored configurations will be enabled Moreover the fixed IP address can be used to check the configuration of the switch e g if the switch cannot be accessed via the expected IP address...

Страница 10: ...performance due to non occurrence of collisions No length restrictions due to cable delays Setting of connected TP switches central remote Attached switches with TP connections should be set to autonegotiation just as terminal units The automatic setting to 1000 Mbps FDX and 100 Mbps FDX also guarantees full bandwidth and maximum performance up to a line length of 100m Power over Ethernet is an at...

Страница 11: ...1 mA 7 0 W 3 84 6 49 W 3 optional 25 31 mA 15 4 W 6 49 12 95 W 4 optional 35 45 mA 34 2 W 12 95 25 5 W Class Using Classification current Supply system power max Power Level max Power over Ethernet PoE PSE MDI X MDI 1 BI_DB PoE PoE 1 BI_DA 2 BI_DB PoE PoE 2 BI_DA 3 BI_DA PoE PoE 3 BI_DB 4 BI_DD 4 BI_DC 5 BI_DD 5 BI_DC 6 BI_DA PoE PoE 6 BI_DB 7 BI_DC 7 BI_DD 8 BI_DC 8 BI_DD Warning Please check com...

Страница 12: ...faces Twisted Pair min typ max Model Pre assembled module for installation in twin boxes Mounting dimensions W x H x D 148 mm x 24 mm x 118 mm Ambient temperature Operation 0 40 C Storage 20 85 C Relative humidity 20 90 non condensing Weight without Options 550 g Electrical safety EN 60950 IT equipment Electrical conditions EN 55022 EMC Further standards CE General and mechanical specifications Sw...

Страница 13: ...Page 13 Technical Data Telephone helpdesk 49 0 2166 27 2220 Dimensions 148 24 1 1 8 ...

Страница 14: ... disabled for each port Prioritization of the VLAN tags selectable according to IEEE802 1p Prioritization Prioritization selectable per each port according to IEEE802 1p IPv4 and IPv6 Four output queues selectable for prioritization weighting per port 4 Prioritization scheme strict queuing 8 4 2 1 weighted fair queuing 3 strict 2 1 0 weighted 2 3 strict 1 0 weighted Discovery Protocols LLDP Link L...

Страница 15: ... Ethernet PoE Functionalities e g VoIP Phones Wireless Access Points and IP Cameras can be supplied with power from the switch system directly External power supp plies for the connected terminal equipment are no longer needed Power Source Equipment PSE The implemented manageable Power over Ethernet PoE feature makes it further possible to power e g IP cameras wireless access points VoIP phones or...

Страница 16: ... the link Appropriate messsages SNMP traps Syslog can also be sent to a central management system Nexans switch systems support all relevant security mechanisms such as IEEE802 1x and MAC based access control In connection with a central authentication server e g RADIUS security in enterprise networks is considerably improved Maximum security is achieved by access control directly at the user port...

Страница 17: ...onfigurations also single parameters selectable Storage of configurations in a database up to 100 history entries Layer 2 3 autodiscovery Time for the software update can be preset Order Numbers NexMan V3 Single license 88301908 NexMan V3 Company license 88301909 With Digital Diagnostic Monitoring Interface to readout specific parameters e g temperature optical input output power SFP Pluggable Tra...

Страница 18: ...t Protocol IEC International Electrotechnical Commission IEEE Institute of Electrical and Electronics Engineers IP International Protection also Ingress Protection IT Information Technology L LLDP Link Layer Discovery Protocol P PoE Power over Ethernet PD Powered Device PSE Power Source Equipment M MAC Media Access Control Mbit s Megabit per Sekunde MDI Medium Dependent Interface MD5 Message Diges...

Страница 19: ... Copy Protocol SFP Small Form factor Pluggable SM Singemode SNMP Simple Network Management Protocol SNTP Simple Network Time Protocol SSH Secure Shell T TCP Transmission Control Protocol TP Twisted Pair V V volt VDC volt direct current VLAN Virtual Local Area Network W W watt ...

Страница 20: ...th such a level of flexibility to ensure that support is provided in par ticularly with frequent moves adds and changes With more than 25 years experience in the development and production of optical solutions the systems from Nexans provide the reliability and the security you expect from your network Nexans Deutschland GmbH Advanced Networking Solutions Bonnenbroicher Str 2 14 41238 Moenchenglad...