Nexa ZRT-106 Скачать руководство пользователя страница 3

Z-Wave Plus

TM

 Info 

Role Type 

Node Type 

Installer Icon 

User Icon 

Slave Sleeping 
Listening 

Z-Wave Plus

TM

 node 

Generic_Thermostat 

Generic_Thermostat 

 

Association Command Class 

Group 

Max Node 

 

Version 

Protocol Library 

3 (Slave_Enhance_232_Library) 

Protocol Version 

6.04(6.81.03) 

 

Manufacturer 

Manufacturer ID 

Product Type 

Product ID 

0x0060 

0x0015 

0x0001 

 

AGI (Association Group Information) Table 

Group 

Profile 

Command Class & Command (List) N bytes 

Group Name(UTF-8) 

General 

Battery Report, 
Device Reset Locally Notification, 
Notification Report 
Sensor Multilevel Report 
Thermostat Mode Report 
Thermostat Setpoint Report 
Protection Report 
Clock Report 

Lifeline 

 

Notification 

Event 

Type 

Event 

Event 
Parameter 
Length 

Event 
Parameter 

The power is applied for the first time   

0x08 

0x01 

0x00 

 

 
Battery 

Battery Report (value) 

Description 

20~100 

Battery Level % 

0xFF 

Low Battery 

 
Command Classes 

 

The module supports Command Classes including… 

  COMMAND_CLASS_ZWAVEPLUS_INFO_V2 

  COMMAND_CLASS_ASSOCIATION_V2 

  COMMAND_CLASS_ASSOCIATION_GRP_INFO 

  COMMAND_CLASS_TRANSPORT_SERVICE_V2 

  COMMAND_CLASS_VERSION_V3 

  COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 

  COMMAND_CLASS_DEVICE_RESET_LOCALLY 

  COMMAND_CLASS_POWERLEVEL 

  COMMAND_CLASS_SECURITY   

  COMMAND_CLASS_SECURITY_2 

  COMMAND_CLASS_SUPERVISION 

  COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4 

  COMMAND_CLASS_BATTERY   

  COMMAND_CLASS_NOTIFICATION_V8 

  COMMAND_CLASS_CONFIGURATION 

  COMMAND_CLASS_SENSOR_MULTILEVEL 

  COMMAND_CLASS_APPLICATION_STATUS 

  COMMAND_CLASS_THERMOSTAT_MODE_V3 

  COMMAND_CLASS_THERMOSTAT_SETPOINT_V3 

  COMMAND_CLASS_PROTECTION 

  COMMAND_CLASS_CLOCK 

 

Basic Command Class 

 

  Basic Get: Command to inquire the status of the device.   

  Basic Report: Report the status of the device.   

  Basic Set: Set the status of the device. 

Basic Set Value 

Description 

0x00 

Energy Heat 

0x0F 

Off   

0xFF 

Heat 

 

 

Z-Wave Configuration 
 

1. 

Temperature Auto Report period setting 

Parameter Number 

Size 

Range 

Default 

1~255 (min) 

120mins 

 

2. 

Temperature offset for internal sensor 

Parameter Number 

Size 

Range 

Default 

-80~+80 Offsets the 

measured temperature by 

-8.0

~+8.0

 

00=0.0

 

Offset 

 

3. 

Maximum Set point value 

Parameter Number 

Size 

Range 

Default 

5~35 for 5

~35

 

35=35

 

 

4. 

Minimum Set point value 

Parameter Number 

Size 

Range 

Default 

5~35 for 5

~35

 

5=5

 

 

5. 

Frost protection temperature 

Parameter Number 

Size 

Range 

Default 

5~15 for 5

~15

 

5=5

 

 

6. 

Open window detect function 

Parameter Number 

Size 

Range 

Default 

0: Disable 

1: Enable 

 

7. 

Open window detect time period 

Parameter Number 

Size 

Range 

Default 

2~30 (min) 

15mins 

 

8. 

Open window detect temperature drop setting 

Parameter Number 

Size 

Range 

Default 

4=2

  , 5=2.5

 

6= 3

, 7=3.5

, 8=4

 

4=2

 

 

9. 

Open window detect delay time select 

Parameter Number 

Size 

Range 

Default 

10~60 (min) 

30mins 

10.  Manual Override takeover period 