Nexa NC-1200 Скачать руководство пользователя страница 67

- 67 - 

 

Function Key Table 

 

 

NULL 

 

UP 

F1 

DOWN 

F2 

LEFT 

F3 

RIGHT 

F4 

PAGE UP 

F5 

PAGE DOWN 

F6 

 

F7 

BS 

F8 

TAB 

F9 

 

F10 

HOME 

ESC 

END 

F11 

ENTER 

F12 

INSERT 

 

DELETE 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание NC-1200

Страница 1: ...1 NC 1200 BARCODE SCANNER Configuration Guide...

Страница 2: ...unication setting 11 2 2 Scanning mode selection 16 2 3 Beeper tone selection 17 2 4 String Options Prefix Suffix 18 2 5 Setup Insertion 19 Chapter 3 BarCode parameters setting 3 1 UPC A 23 3 2 UPC E...

Страница 3: ...common communication setting If you need to change these settings programming is accomplished by scanning the bar codes in this guide 1 2 How to set up the parameter Step 1 Scan the start configuratio...

Страница 4: ...rcodes such as Hexadecimal barcodes For example prefix suffix etc Numeric barcodes For example inter character delay max min length To complete the change of setting you will need to read the Confirm...

Страница 5: ...presetting is requested for USB interface Scanning USB bar code after the cable is changed and activating the scanner by plugging the USB cable again USB interface complies with HID keyboard which me...

Страница 6: ...Keyboard emulation parameters setting Start configuration End configuration ITEM OPTION Device Selection for keyboard Interface IBM AT IBM XT IBM PS 2 30 80 IBM 5550 PS 2 25 30 NEC 9801 Reserved 1 Re...

Страница 7: ...7 Start configuration End configuration ITEM OPTION Language for Keyboard Interface USA ITALIAN SPANISH FRENCH GERMAN JAPANESE Multi Language Support Reserved 1...

Страница 8: ...y Disable Enable Emulate External Keyboard Disable Enable ALT Mode Disable Enable NOTE Emulate External Keyboard Scan the barcode below if you do not have an external keyboard After scanning the Emula...

Страница 9: ...9 Start configuration End configuration ITEM OPTION Caps Lock Disable Enable Num Lock Disable Enable Inter Character Delay Default 00 Ref Appendix 00 64H...

Страница 10: ...0 Start configuration End configuration ITEM OPTION Terminator None CR Tab ESC CR LF Block transmission delay Default 00 Ref Appendix 00 0AH Keyboard Speed Default 00 high clock rate Ref Appendix 00 0...

Страница 11: ...11 2 1 2 RS 232 communication setting Start configuration End configuration ITEM OPTION Baud Rate 1200bps 2400bps 4800bps 9600bps 19200bps 38400bps Data Bits 7 Bits 8 Bits...

Страница 12: ...12 Start configuration End configuration ITEM OPTION Stop Bits 1 Stop Bits 2 Stop Bits Parity NONE ODD EVEN Mark Space...

Страница 13: ...nd configuration ITEM OPTION Inter character delay Default 00 Ref Appendix 00 64H Block transmission delay Default 00 Ref Appendix 00 0AH Response delay Default 00 Ref Appendix 00 0AH HANSHAKING None...

Страница 14: ...14 Start configuration End configuration ITEM OPTION Terminator For RS 232 None CR LF CR LF Tab STX ETX EOT...

Страница 15: ...15 Start configuration End configuration ITEM OPTION Handshaking None RTS CTS ACK NAK Xon Xoff...

Страница 16: ...ection Start configuration End configuration ITEM OPTION Reading Mode Trigger On Good Read Off Trigger On Off Continuous Trigger Off Continuous Testing Continuous Trigger on Continuous Auto power on F...

Страница 17: ...eeper tone selection Start configuration End configuration ITEM OPTION Beep Tone Default 09H Ref Appendix 00 10H Beep Sound Duration Default 05H Ref Appendix 00 10H Power On Beeper Enable Disable Beep...

Страница 18: ...t Prefix Code ID Bar Code Suffix How to set up a prefix To configure as prefix 1 Scan Start Configuration barcode 2 Scan Preamble bar code 3 Scan twice from FULL ASCII table 4 Scan Confirm configurati...

Страница 19: ...This section describes how to setup the insertion of output NOTE Max 10 charters can be inserted each time Max Insertion group is only two Insertion group 01 or 02 can be used in different kinds of ba...

Страница 20: ...u wish to place the character 6 Scan Start Configuration barcode 7 Scan G1 Character Position 8 Scan 0 and 3 from FULL ASCII Table which presents the position 9 Scan Confirm configuration barcode 10 S...

Страница 21: ...amble Default 00 Ref Appendix Postamble Default 00 Ref Appendix G1 Insertion character Default 00 Ref Appendix G2 Insertion character Default 00 Ref Appendix G1 Character Position to be inserted Defau...

Страница 22: ...22 Start configuration End configuration ITEM OPTION Bar Code ID Disable Enable Accuracy Read 1 Time Read 2 Times Positive and negative bar code Bar equals high Bar equals low...

Страница 23: ...to the ASCII Table and scan label that represent the desired characters to be inserted 3 Scan Confirm configuration bar code 4 Scan End configuration bar code Start configuration End configuration Con...

Страница 24: ...TION UPC A Expand to EAN 13 Disable Enable Check Digit Send Disable Enable Truncate Leading Zero Disable Enable Truncate Leading Default 00 Ref Appendix 00 0DH Truncate Ending Default 00 Ref Appendix...

Страница 25: ...25 Start configuration End configuration ITEM OPTION Supplement digits NONE 2 digits 5 digits 2 or 5digits Auto discriminate Supplement...

Страница 26: ...26 3 2 UPC E Start configuration End configuration ITEM OPTION Read Disable Enable Code ID setting Default G Ref Appendix 20 7EH...

Страница 27: ...ation ITEM OPTION UPC E Expand to UPC A Disable Enable Check Digit Send Disable Enable Truncate Leading Default 00 Ref Appendix 00 08H Truncate Ending Default 00 Ref Appendix 00 08H Insert group selec...

Страница 28: ...28 Start configuration End configuration ITEM OPTION Truncate Leading Zero Disable Enable Supplement digits None 2 digits 5 digits 2 or 5 digits Auto discriminate Supplement...

Страница 29: ...ation End configuration ITEM OPTION Read Disable Enable Code ID setting Default H Ref Appendix 20 7EH Check Digit Send Disable Enable Truncate Leading Default 00 Ref Appendix 00 0DH Truncate Ending De...

Страница 30: ...iguration End configuration ITEM OPTION Supplement digits None 2 digits 5 digits 2 or 5 digits Auto discriminate Supplement ISBN ISSN Conversion Disable Enable Insert group selection Default 00 Ref Ap...

Страница 31: ...4 EAN 8 Start configuration End configuration ITEM OPTION Read Disable Enable Code ID setting Default I Ref Appendix 20 7EH Check Digit Send Disable Enable Truncate Leading Default 00 Ref Appendix 00...

Страница 32: ...tion End configuration ITEM OPTION Truncate Ending Default 00 Ref Appendix 00 08H Supplement digits None 2 digits 5 digits 2 or 5 digits Auto discriminate Supplement Insert group selection Default 00...

Страница 33: ...3 5 Code39 Start configuration End configuration ITEM OPTION Read Disable Enable Code ID setting Default J Ref Appendix 20 7EH Check sum verification Disable Enable Check sum transmission Disable Ena...

Страница 34: ...art configuration End configuration ITEM OPTION Append Disable Enable Min code length Default 00 Ref Appendix 00 32H Max code length Default 32H Ref Appendix 00 32H Format Standard Code39 Code 39 Full...

Страница 35: ...End configuration ITEM OPTION Transmit Start End Character Disable Enable Truncate Leading Default 00 Ref Appendix 00 32H Truncate Ending Default 00 Ref Appendix 00 32H Insert group selection Default...

Страница 36: ...36 3 6 Codabar Start configuration End configuration ITEM OPTION Read Disable Enable Code ID setting Default K Ref Appendix 20 7EH...

Страница 37: ...37 Start configuration End configuration ITEM OPTION Check sum verification Disable Enable Check sum transmission Disable Enable Append Disable Enable Truncate Leading Default 00 Ref Appendix 00 7EH...

Страница 38: ...guration End configuration ITEM OPTION Truncate Ending Default 00 Ref Appendix 00 7EH Start End type ABCD ABCD abcd abcd abcd tn e Start End transmission Disable Enable Min code length Default 05 Ref...

Страница 39: ...39 Start configuration End configuration ITEM OPTION Max code length Default 3CH Ref Appendix 00 3CH Insert group selection Default 00 Ref Appendix 00 02H...

Страница 40: ...40 3 7 Code93 Start configuration End configuration ITEM OPTION Read Disable Enable Code ID setting Default L Ref Appendix 20 7EH Check sum verification Disable Enable...

Страница 41: ...um transmission Disable Enable Min code length Default 00 Ref Appendix 0 50H Max code length Default 50H Ref Appendix 0 50H Truncate Leading Default 00 Ref Appendix 00 7EH Truncate Ending Default 00 R...

Страница 42: ...42 3 8 Code 128 Start configuration End configuration ITEM OPTION Read Disable Enable Code ID setting Default M Ref Appendix 20 7EH Check sum verification Disable Enable...

Страница 43: ...43 Start configuration End configuration ITEM OPTION Check sum transmission Disable Enable FNC2 Append Disable Enable UCC EAN128 Disable Enable FNC1 transmission Disable Enable...

Страница 44: ...TION Truncate Leading Default 00 Ref Appendix 00 7FH Truncate Ending Default 00 Ref Appendix 00 7FH Min code length Default 00 Ref Appendix 00 7FH Max code length Default 7FH Ref Appendix 00 7FH Inser...

Страница 45: ...nterleaved 2 of 5 Start configuration End configuration ITEM OPTION Read Disable Enable Code ID setting Default N Ref Appendix 20 7EH Check sum verification Disable Enable Check sum transmission Disab...

Страница 46: ...TION Truncate Leading Default 00 Ref Appendix 00 7EH Truncate Ending Default 00 Ref Appendix 00 7EH Min code length Default 00 Ref Appendix 00 7FH Max code length Default 7FH Ref Appendix 00 7FH Inser...

Страница 47: ...2 of 5 Start configuration End configuration ITEM OPTICON Read Disable Enable Code ID setting Default O Ref Appendix 20 7EH Min code length Default 00 Ref Appendix 00 32H Max code length Default 32H...

Страница 48: ...on ITEM OPTION Truncate Leading Default 00 Ref Appendix 00 32H Truncate Ending Default 00 Ref Appendix 00 32H Check sum verification Disable Enable Check sum transmission Disable Enable Insert group s...

Страница 49: ...49 3 11 Matrix 2 of 5 Start configuration End configuration ITEM OPTION Read Disable Enable Code ID setting Default P Ref Appendix 20 7EH Check sum verification Disable Enable...

Страница 50: ...smission Disable Enable Truncate Leading Default 00 Ref Appendix 00 50H Truncate Ending Default 00 Ref Appendix 00 50H Min code length Default 0B Ref Appendix 00 50H Max code length Default 50H Ref Ap...

Страница 51: ...CHINA POSTAL CODE Start configuration End configuration ITEM OPTION Read Disable Enable Code ID setting Default Q Ref Appendix 20 7EH Check sum verification Disable Enable Check sum transmission Disab...

Страница 52: ...TION Truncate Leading Default 00 Ref Appendix 00 50H Truncate Ending Default 00 Ref Appendix 00 50H Min code length Default 00 Ref Appendix 00 50H Max code length Default 50H Ref Appendix 00 50H Inser...

Страница 53: ...53 3 13 MSI Plessey Start configuration End configuration ITEM OPTION Read Disable Enable Code ID setting Default R Ref Appendix 20 7EH Check sum verification Disable MOD 10 MOD 10 10 MOD 11 10...

Страница 54: ...smission Disable Enable Truncate Leading Default 00 Ref Appendix 00 3CH Truncate Ending Default 00 Ref Appendix 00 3CH Min code length Default 00 Ref Appendix 00 3CH Max code length Default 3CH Ref Ap...

Страница 55: ...3 14 CODE 32 Start configuration End configuration ITEM OPTION Read Disable Enable Code ID Setting Default S Ref Appendix 20 7EH Check sum verification Disable Enable Check sum transmission Disable En...

Страница 56: ...56 Start configuration End configuration ITEM OPTION Truncate Leading Default 00 Ref Appendix 00 0AH Truncate Ending Default 00 Ref Appendix 00 0AH Insert group selection Default 00 Ref Appendix 00 02...

Страница 57: ...57 3 15 CODE 11 Start configuration End configuration ITEM OPTION Read Disable Enable Code ID setting Default T Ref Appendix 20 7EH Check sum verification Disable Enable...

Страница 58: ...smission Disable Enable Truncate Leading Default 00 Ref Appendix 00 50H Truncate Ending Default 00 Ref Appendix 00 50H Min code length Default 00 Ref Appendix 00 50H Max code length Default 50H Ref Ap...

Страница 59: ...16 Telepen Start configuration End configuration ITEM OPTION Read Disable Enable Code ID setting Default V Ref Appendix 20 7EH Check sum verification Disable Enable Data Format Only Numnic ALPHA Full...

Страница 60: ...smission Disable Enable Truncate Leading Default 00 Ref Appendix 00 40H Truncate Ending Default 00 Ref Appendix 00 40H Min code length Default 00 Ref Appendix 00 40H Max code length Default 40H Ref Ap...

Страница 61: ...N Function Key Disable Enable Code 39 format Full ASCII Code 39 To scan a function key barcode label Full ASCII Code 39 must be enabling Please refer to Full ASCII Code 39 Table to produce the functio...

Страница 62: ...62 PAGE UP E F5 U PAGE DOWN F F6 V BS H F7 W TAB I F8 X HOME K F9 Y END L F10 Z ENTER M ESC A INSERT N F11 B DELETE O F12 C...

Страница 63: ...63 Appendix A...

Страница 64: ...HT 41 29 10 0A LF 42 2A 11 0B VT 43 2B 12 0C FF 44 2C 13 0D CR 45 2D 14 0E SO 46 2E 15 0F SI 47 2F 16 10 DLE 48 30 0 17 11 DC1 49 31 1 18 12 DC2 50 32 2 19 13 DC3 51 33 3 20 14 DC4 52 34 4 21 15 NAK...

Страница 65: ...3 49 I 105 69 i 74 4A J 106 6A j 75 4B K 107 6B k 76 4C L 108 6C l 77 4D M 109 6D m 78 4E N 110 6E n 79 4F O 111 6F o 80 50 P 112 70 P 81 51 Q 113 71 q 82 52 R 114 72 r 83 53 S 115 73 s 84 54 T 116 74...

Страница 66: ...66 Table Hex HEXADCIMAL Confirm configuration End Configuration...

Страница 67: ...67 Function Key Table 0 1 0 NULL 1 UP F1 2 DOWN F2 3 LEFT F3 4 RIGHT F4 5 PAGE UP F5 6 PAGE DOWN F6 7 F7 8 BS F8 9 TAB F9 A F10 B HOME ESC C END F11 D ENTER F12 E INSERT F DELETE...

Страница 68: ...68 DEFAULT CHECK VERSION Version 2 0...

Отзывы: