MODEL: GNS-2236/RF 

(With 9V Battery Back-up)

  

 

15 

0086-CPR-632447 

Nexa13546-CPR-632447 

EN14604:2005/AC:2008 

Nexa Trading AB, Box 12200, 40242 Gothenburg 

Sweden 

Fire Safety and installed in buildings 

 
Main Features : 

 

Photoelectric Sensor For Slow 
Smoldering Fires 

 

Power / Alarm indicator 

 

HUSH FEATURE 

 

Battery  Back Up  

 

Low Battery Warning 

 

Wireless interconnectable (Up To 20 
smoke And/Or heat Alarms) 

 

Dip switch for coding  

 

Supplied with Fixing Kit 

 

Loud 85dB Alarm Signal 

 

Dust cover 

 

This instruction leaflet contains important 
information on the correct installation and operation 

of your heat alarm. Read this leaflet fully before 
attempting installation and retain for future 

reference. 

 

SPECIFICATION 

Power Source  

:  220-240Vac~ 50-60Hz with    

   9V battery back-up (battery  
   included) 

Battery Back-up 

  :  9V Alkaline Battery (Gold Peak 

1604A, Energizer 522, Duracell 

MN1604) 

Battery Back-up Life 

  :  In the event of a break in the  

mains supply the battery will give 

detector operation for  one month 

minimum 

Operation Current 

  : <40mA operation (In Alarm) 

Transmit & Receive frequency: 

868.4MHz

 

Digital modulation method: GFSK 

Transmitting & Receiving distance: over 80M in open space 

Transmit data rate 

  : 50Kbps 

Coding selection 

  : 16 combinations 

Max. wireless interconnection: 20 units 

Max. wire interconnection   : 40 units 

Sensitivity to smoke 

  : 0.65-1.52 % per foot obscuration 

Operation Temperature    : 0

o

C-40

o

Ambient Humidity 

  : 10%-90% 

Alarm Sound Level 

  : 85 Decibels at 3 metres  

 

PRODUCT DESCRIPTION 

GNS-2236/RF is a multiple station photoelectric smoke alarm 

with a radio link mounting base which allows it to be 

interconnected to other Nexa alarms. (Can be mixed and 

matched with the NEXA Photoelectric Smoke Alarm GNS-

2236/RF and MTS-166/RF) The radio link base has both signal 

transmitter and receiver built-in. It transmits a Radio 

Frequency(RF) alarm signal when the unit detects smoke. When 

it receives an RF alarm signal from other unit, it will sound.  This 

interconnect feature allow up to 20 units to be interconnected 

together within 100 meters and thus all alarms will sound when 

any one is activated.  Using the wireless signal transmission 

technology awards wiring location problem and allows the 

smoke and heat alarms to be placed futher apart when 

compared to a wired installation.   

 

Note: This smoke alarm cannot be connected to any other 

device such as a fire alarm panel. 

 

All the Smoke Alarms should be interconnected to ensure the 

early warning will be heard, particularly by somebody sleeping. A 

properly designed early warning fire system ensures the alarm is 

given before the escape routes become blocked with smoke.  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

 

 

 

LOCATING THE SMOKE ALARM 

If your dwelling is on a single storey, for minimum protection 

you should fit an alarm in a corridor or hallway between the 

sleeping and living areas (incl. Kitchens). Place it as near to 

the living areas as possible and ensure the audible alarm can 

be heard when the bedrooms are occupied. See Figure 1 for 

examples. 

 

If your dwelling is multi-storey, for minimum protection one 

alarm should be fitted at the bottom of the staircase with further 

alarms fitted on each upstairs landing. This includes 

basements but excludes crawl spaces and unfinished attics. 

See Figure 2 for examples. 

 

NOTE: For maximum protection an alarm should be fitted in 

every room (except kitchen, bathroom and garage).  

 

DO NOT FIT AN ALARM IN THE KITCHEN OR BATHROOM, 

as cooking fumes or steam may trigger the alarm. 

DO NOT FIT ALARM IN GARAGE, as exhaust fumes are likely 

to set it off. 
 

POSITIONING THE SMOKE ALARM 

Ceiling Mounting  

As hot smoke rises and spread out, it is advisable to mount on 

a ceiling in a central position. Avoid areas where there is no air 

circulation. E.g. Corners of rooms and keep away from items 

which may prevent the free flow of air. Place the unit at least 

300 mm from and light fitting or decorative object which might 

obstruct smoke entering the alarm. Keep at least 300 mm away 

from walls. See Figure 3i. 

Wall Mounting 

Do not mount tight into the corners. Put the top edge of your 

smoke alarm between 150 and 300mm below the ceiling. Keep 

at least 300mm from room corners. See Figure 3i 

On a Sloping Ceiling 

In areas with sloping or peaked ceilings install your Smoke 

Alarm 900mm from the highest point measured horizontally 

because “dead air” at the apex may prevent smoke from 

reaching the unit. See Figure 3ii. 

 

 

Areas to be avoided include the following : 

 

Situations where the temperature may fall below 0

o

C or 

rise above 40

o

C  

 

Humid areas such as bathrooms, kitchens, shower 

rooms where the relative humidity may exceed 90% 

 

Near a decorative object, door, light fitting, window 

molding etc., that may prevent smoke from entering the 

alarm. 

 

Fume filled environments such as garages. Exhaust 

gases may cause false alarms. 

 

Adjacent to or directly above hot components such as 

radiators or wall vents that can effect the direction of air 

currents. 

 

In very dusty or dirty environments such as workshops. 

 

Locate unit at least 1.5m and route wiring at least 1m away 

for fluorescent light fittings as electrical “noise” and/or 

flickering may affect the unit. Do not wire into the same circuit 

as fluorescent lights or dimmers. 

 

Do not locate in insect infested areas. Insects and 

contamination on the alarm sensor can increase its response 

time. 

 

INSTALLING THE SMOKE ALARM 

WARNING – This smoke alarm is mains powered and requires 

wiring by a qualified electrician in accordance with the current 

IEE Regulations for Electrical Installations (BS7671). 

The circuit used to power the smoke alarm must be a dedicated 

permanent supply that cannot be switched off accidentally by 
the normal user. Before installing ensure the electrical supply 

is isolated.

 

WARNING: To prevent injury, this smoke alarm must be 

securely attached to the ceiling/wall in accordance with the 

installation instructions.

 

All handwired interconnect smoke alarms must be supplied from a 

single power circuit and a common neutral must be used. 

WARNING:Do not connect the interconnect wire to Live or 

Neutral.

 

 

Disconnect the AC main power from the circuit that is going to 

be used. 

 

Having established the mounting location install a junction 

box suitable for locating the termination point. Ensure that 

there is no other electrical wiring or pipe work in the area 

adjacent to the mounting surface. 

 

Unlock the detector unit from the base by pushing up the 

temporary latch with a screw driver. See Figure 4 

 

 

 

 

 

 

 

 

 

 
 

 

 

 

 

 

Set the coding. Each unit comes a four positions dip 

switch(see Figure 6) for coding the transmit and receive 

frequency to prevent interference with any other RF 

equipment.  There are 16 combinations. 

 

Figure 6 – DP Switch setting facility 

 

 

 
 

 

 

 

 

 

LANDING

HALL

BATHROOM

BEDROOM

LIVING

ROOM

KITCHEN

BASEMENT

LIVING
ROOM

BATHROOM

KITCHEN

BEDROOM

BEDROOM

BEDROOM

BEDROOM

HALL

MAXIMUM PROTECTION
MINIMUM PROTECTION

KEY

FIGURE 1 - SINGLE STOREY DWELLING

FIGURE 2 - 2/3  STOREY DWELLING

 

Figure 4 – Release Temporary Lock

 

 

Отзывы: