Newton Waterproofing NP400LLPS Скачать руководство пользователя страница 4

4

For more information, visit us online www.newtonwaterproofing.co.uk

INTRODUCTION, FEATURES, ENCLOSURE & CONNECTIONS

PANEL HIGHLIGHTS & CONNECTIONS

The 

Newton NP400LLPS

 pumping system comprises of a Control Panel, Probe Set and a single 

Newton NP400PP

 

puddle pump. The panel is simple to install and is enclosed in an IP55 rated casing.
The panel has one power supply input which should be connected to a 230V power supply. 
The Newton SP1 Panel features interfaces for use with the optional 

Newton High Water Level Alarm

, the  

Newton Dialer,

 as well as connections to whole house alarm and monitoring systems. 

The control panel uses a probe set that monitors the water level and informs the panel of:
•  High water level - Pump is started
•  Low water level - Pump is stopped
•  Alarm level - Panel Alarm sounds
A typical system is shown below:

*

 There is only one 230 VAC power supply. Connection is either directly from mains AC or from Inverter AC. 

ENCLOSURE

The Newton NP400LLPS panel is housed in 225 mm wide x 145 mm deep x 315 mm high ABS plastic enclosure 

with 6 knockouts for fitting plastic cable glands, ready for the following cables:
Main power, 1 x Probe Set, 1 x pumps and 1 x Dialer or BMS. 2 knockouts will not be used. If optional Alarm is 

fitted, use one of the two spare knockouts.
Parts:
•  1 x Panel
•  1 x NP400PP Puddle Pump
•  1 x Probe Set 
The enclosure is fixed to the wall using fixings that are suitable for the weight of the unit and your wall type. The 

face plate is attached to the back box with the supplied screws. A ribbon cable connects the face plate display to 

the main PCB. 

Newton 

SP1

Panel

Probe 

Set

Pump

Dialer

PA5 - (Option)

BMS

(Option)

Power 

Inverter 

(Option)*

Grid mains 

power supply 

230V AC 13A* 

Battery

Battery

OPTIONAL 

FURTHER

BATTERIES

Alarm

(Option)

Содержание NP400LLPS

Страница 1: ...Rev 5 2 16 April 2019 Newton Waterproofing Systems Operational Manual Basement Pumping Systems and Ancillaries NEWTON NP400LLPS SP1 Low Level Pumping System DATA SHEET SDS OPERATIONAL MANUAL...

Страница 2: ...stalled Installation Company Installation Engineer Service Contact Number WARNINGS SHOCK HAZARD DO NOT OPEN THIS PUMPING SYSTEM PANEL MUST ONLY BE INSTALLED BY TRAINED ENGINEERS NO USER SERVICE PARTS...

Страница 3: ...ot authorised by the manufacturer Problems caused by connecting devices not supplied or authorised by the manufacturer Warranty Information This warranty gives you specific legal rights and you may al...

Страница 4: ...s A typical system is shown below There is only one 230 VAC power supply Connection is either directly from mains AC or from Inverter AC ENCLOSURE The Newton NP400LLPS panel is housed in 225 mm wide x...

Страница 5: ...tting to the next trimmer up which for a 7 A pump would be 12 A DISPLAY AND CONTROLS INFORMATION The panel face is fitted with a single button for operation of one pump AUT 0 MAN AUT relates to automa...

Страница 6: ...voltage rated cables cannot be run in the same conduit as high voltage 230V AC cables The Panel must be earthed If the water level is above the alarm probe on first powering up the panel the alarm may...

Страница 7: ...OBE SET Low voltage PUMP MAINS OUTPUT 230V AC NEWTON DIALER Option ALARM Option SWITCH 2 T1 4 T2 6 T3 2 T1 4 T2 6 T3 From Grid Mains N L E Input 1 0V CONNECTION DIAGRAM 1 2 3 4 5 6 7 8 9 10 11 12 13 1...