EO
automatic execution on power on
IMM PGM MIP
USAGE
♦
♦
SYNTAX
xx
EO
nn or xx
EO
?
PARAMETERS
Description
xx
[ int ] - program number
nn
[ int ] - number of times of execution
Range
xx
-
1
to
100
nn
-
1
to
2e9
Units
xx
-
none
nn
-
none
Defaults None
DESCRIPTION
This command sets the program number that is automatically executed on power
on. If
nn
is missing, the
xx
numbered program is executed once.
RETURNS
If the sign
“?”
takes place of
nn
value, this command reports the number of the
program that is executed on power on and the number of times of execution.
REL. COMMANDS
QP
-
quit programming mode
EX
-
execute stored program
AP
-
abort stored program execution
XX
-
erase program
EXAMPLE
3EO
|
set program #3 to be executed once on power on
EO?
|
query the program number executed on power on
EO,3,1
|
controller returns program #3 executed once on power on
EO
|
Reset automatic program execution – no program is
executed on power on
3-54
Section
3
–
Remote
Mode
Содержание ESP300 Series
Страница 1: ...ESP300 Motion Controller Driver User s Manual...
Страница 4: ...ESP300 1999 EU Declaration of Conformity iv Preface...
Страница 29: ...This page is intentionally left blank Section 2 Modes of Operation 1 15...
Страница 30: ......
Страница 230: ...4 16 Section 4 Advanced Capabilities...
Страница 274: ...This page is intentionally left blank 6 6 Section 6 Servo Tuning...
Страница 290: ...This page is intentionally left blank B 6 Appendix B Trouble Shooting and Maintenance...