ST
stop motion
IMM
PGM
MIP
USAGE
♦
♦
♦
SYNTAX
xx
ST
PARAMETERS
Description
xx
[ int ] -
axis number
Range
xx
-
1
to
MAX AXES
Units
xx
-
none
Defaults
xx
out of range:
error 9, AXIS NUMBER OUT OF RANGE
DESCRIPTION
This command stops a motion in progress using deceleration rate programmed
with
AG
(set deceleration) command on the specified axes. If the ST command
is sent with no axis parameter, all axes are stopped.
RETURNS
none
REL. COMMANDS
AB
-
abort motion
AG -
set deceleration
MF -
motor power off
EXAMPLE
2PA40
|
move axis # 2 to absolute position 40
2ST
|
stop motion on axis # 2