The furnace(s) installed in your unit is a forced-air furnace fueled by Propane
gas. If your unit is equipped with two furnaces, the living area furnace is
controlled by the air conditioner wall thermostat that controls the heating, and
cooling of the unit. The furnace installed in the bath/bedroom area is controlled
by the thermostat in the bedroom. The heat is supplied to the unit through
ducts in the floor. The furnace will not operate properly if the air flow at the
floor registers, or the air return to the furnace, is blocked by personal or
storage items. Storage under the cabinets should be done carefully to prevent
crushing or damaging the furnace ducting or blocking of the cold air return.
Smoke and fumes may be created as a result of the residual burn off of the
manufacturing compounds that are sometimes present the first time the furnace
is used. This is normal.
To minimize the smoke and fumes, the initial lighting of the furnace should
be done with the windows and doors open. Continue until the residue is
completely burned off. To operate, set the thermostat to the desired
temperature setting and turn the thermostat to the on position. Allow 60
seconds for the furnace to begin operating. To shut down the furnace, turn the
thermostat to the off position. After the furnace has been turned off, the fan
will run for approximately 60 seconds to cool down.
For your safety, do not use gasoline or other flammable liquids in the vicinity
of the furnace or any other appliance. Clean the complete furnace and air tube
passageways periodically to remove dust, lint, etc. Check the gas system for
leaks at least once a year. Check and clean the blower wheel annually. On the
exterior of the coach you will find a furnace cover. There are no owner
serviceable parts on the furnace. This cover should be removed by authorized
service technicians only. The furnace should be thoroughly cleaned before the
start of each heating season. Any debris in the system may restrict air flow for
combustion, bind the combustion air impeller, or prevent the blower motor
from running properly. Also, check the burner pilot orifices for debris. Lint
accumulations may cause the blower to become unbalanced, vibrate, restrict
the ability of the blower to move air. If lint is blown into the heat exchanger,
it may cause odors or create a fire hazard. Contact an authorized service
technician for annual cleaning. Consult the manufacturer’s operating
instructions in your Owner’s Package for further information.
Содержание torrey pine 2008
Страница 1: ......
Страница 6: ...1 2 2008 Torrey Pine Fifth Wheel by Newmar ...
Страница 12: ...2 2 2008 Torrey Pine Fifth Wheel by Newmar ...
Страница 40: ...3 2 2008 Torrey Pine Fifth Wheel by Newmar ...
Страница 55: ...4 2 2008 Torrey Pine Fifth Wheel by Newmar ...
Страница 60: ...5 2 2008 Torrey Pine Fifth Wheel by Newmar ...
Страница 68: ...6 2 2008 Torrey Pine Fifth Wheel by Newmar ...
Страница 77: ...7 2 2008 Torrey Pine Fifth Wheel by Newmar ...
Страница 89: ...8 2 2008 Torrey Pine Fifth Wheel by Newmar ...
Страница 95: ...9 2 2008 Torrey Pine Fifth Wheel by Newmar ...