Quick Reference Contents

The front and rear panel features of the Power Modules are illustrated below, along with the page number where information on each 

particular feature is located.

FAX: (714) 957-1621

TEL: (714) 751-0488

[email protected]

NEWPORT BEACH, CA. USA

NewmarTelecom.com

Figure 1: Power Module – Front Panel (2500W models)

Power Module “On” 

Indicator Lamp 

Page 7

Input Switch/

Circuit Breaker 

 Page 4

Output Voltage 

Adjustment Pot 

Page 6

Output Voltage 

Test Points

Page 6

Status Indicator Lamp 

Page 7

Output Termnals 

Page 5

Remote Alarm Contacts

Page 8

Chassis Ground Stud

Page 5

Temperature Probe

Access Plate

Page 8

Ac Input 

Wiring Access

Page 4

Figure 2: Power Module – Rear Panel (2500W models)

Output Termnal

Cover 

Page 5

Содержание PM-24-80

Страница 1: ...D EMI COMPATIBILITY 3 B EMI Electro magnetic Interference 3 C Other Factors 3 III INSTALLATION 4 A Materials Provided 4 B Mounting 4 C AC Input Wiring 4 D DC Output Wiring 4 E Parallel Wiring 5 F Chas...

Страница 2: ...and rear panel features of the Power Modules are illustrated below along with the page number where information on each particular feature is located FAX 714 957 1621 TEL 714 751 0488 techservice new...

Страница 3: ...an range from 1 to 100 times the normal AC voltage level and can last for a fraction of a cycle to a few cycles Transient disturbances can be placed into two categories Lightning generated Equipment g...

Страница 4: ...PM Bracket attachment holes in the PM chassis are provided to allow for 6 forward mounting only C A C Input Wiring Input Voltage the PM is designed to accept 207 253 VAC 50 60 HZ single phase input F...

Страница 5: ...tage If adjustment is necessary use a small at tip screwdriver to turn the OUTPUT VOLTAGE ADJUST potentiometer on the front panel until the voltmeter reads the desired system output voltage 4 Shut off...

Страница 6: ...ber e g PM 48 50 is rated at 50 amps continuous duty To prevent overload when recharging severely discharged batteries current is limited at approximately 105 of the continuous duty rating by a curren...

Страница 7: ...he rear panel which secure the top cover Remove the two screws on the sides near front which secure top cover 3 Locate the two fans located on one end of the main circuit board near the rear of the PM...

Страница 8: ...C 48 v model or 60 mV per C 24 v model If the battery reaches 50 C the PM will turn itself off The PM will automatically restart once the battery temperature drops approximately 5 10 C Temperature Pr...

Страница 9: ...er con rm AC input or is not receiving correct input voltage voltage Check input connections 2 PM limiting its output due to overload 2 Reduce DC load and or determine or ambient over temperature cond...