A) Materials Provided

Prior to installation, check to ensure that each of the following items have 

been included with the packaging. For any missing items please contact 

the factory or warehouse.

(2) ea. mounting brackets for 19” rack mounting (# 13917-0)

(2) ea. mounting brackets for 23” rack mounting (# 13918-0)

(6) ea. 6-32 X 3/8” pan head phillips screws

(1) ea. Molex “pigtail” connector

(1) ea. IEC 115V NEMA 5-15P AC input power cord 

     (560 watt models only)

(1) ea. 115V NEMA  5-20P AC input power cord (1000 watt and PM-12-45  

 

models only)

(1) ea. input connector/adaptor for 115V installations (1,000 watt and 

  PM-12-45 models only); Note: 230 connector/adaptor has been factory  

 

installed along with 230V power cord.

(1) ea. Installation/Operation manual

(1) ea. Customer Satisfaction/Warranty card

(1) ea. Output terminal cover (560 watt models only)

B) Mounting

The PM is provided with two pairs of mounting ears: one for 19” rack 

mounting (# 13917-0) and one for 23” rack mounting (# 13918-0). Six # 

6-32 x 3/8” pan head Phillips screws are provided for attaching the ears 

to the PM chassis. Select the appropriate set of ears and fasten to the PM 

sides.

Note there are three sets of a triangular pattern of 6-32 tapped holes 

on each side of the PM. When rack mounting (two posts) the PM it is 

recommended that the ‘center mount’ holes (6” set back from the PM’s 

front panel) be used.  The set of holes nearest the front panel and the 

set nearest the rear panel are normally used when installing the optional 

Universal Mounting Bracket (UMB).

For four post mounting, please contact the factory for a second set of ears 

(specify 19” or 23” and the model no.), mount one pair of ears to the front 

holes and the second pair of ears to the center or rear most tapped holes. 

Adjust your cabinet rail front to back distance so it matches the mounting 

holes on the PM.

Note: Due to the weight of the Power Module, we do not recommend flush 

mounting the PM with the mounting ears attached to the forward most 

mounting holes unless rear support is provided.

C) AC Input Wiring and Voltage Selection

1) 560 Watt Models Only

Input Wiring: These models are provided with an IEC power cord (in the 

installation kit) with a NEMA 5-15 plug for a 115V AC outlet on one end and 

a molded socket at the other which fits the entry module at the rear of the 

PM. If the 5-15 plug is not suited to the available AC outlet, 1) obtain an 

IEC cord with appropriate plug or 2) cut off the 5-15 plug, obtain the correct 

plug for the outlet and attach it to the provided IEC cord. (Plug should be 

rated at 15 amps minimum). When replacing the plug, pay careful attention 

to the pin wiring as follows:

 Brown.........................AC Hot (over-current protected)

 Blue............................AC Neutral

 Green*........................AC Ground (safety, earth)

  * may be Green with Yellow Stripe

Input Voltage Selection: As shipped from the factory, the PM is set up for 

230V AC input. For 115V AC applications set the recessed 115/230 

input select switch located on the left hand side of the PM into the proper 

position. Positions are identified on the switch. Use a small screwdriver to 

slide the switch into position. No adjustment is necessary for either 50 or 

60 Hz input.

2) 1,000 Watt and PM-12-45 Models Only

Input Wiring - 230 VAC Applications: 1000 watt  models are factory 

equipped with a power cord which has a NEMA 6-15 plug for a 230V AC 

outlet. If the 6-15 plug is not suited to the available AC outlet, obtain one 

which is suitable, then cut off and replace the existing plug—or, if the 

installation requires, simply hard-wire the cord into the AC distribution 

system. Color-coding of the AC wiring is identical to that specified for the 

560 watt models above.

Input Wiring - 115 VAC Applications: 1000 watt and PM-12-45 watt models 

are also supplied with a 115V AC power cord which has a NEMA 5-20 plug 

115V, 20 amp outlets. When installing this cord pay careful attention to the 

color coding of the wiring as follows:

 Black............................AC Hot (over-current protected)

 White............................AC Neutral

 Green*..........................AC Ground (safety, earth)

  * may be Green with Yellow Stripe

 

Input Voltage Selection:

 As shipped from the factory the PM is set up for 

230V AC input . For 115V applications it is necessary to replace an internal 

AC connector/adaptor. Refer to FIGURE 4 on the following page in the 

replacement procedure which follows:

Figure 4: AC Input Wiring Compartment 
(PM rear view; 1,000 watt and PM-12-45 models)

1) The AC input wiring compartment cover on the rear of the unit must be 

detached but not removed, so that the AC input wiring remains attached. 

To accomplish this remove only the two outside screws which secure the 

cover to the rear panel. Be careful not to loosen the AC wires which are 

attached to the internal wiring terminal.

2) Remove the 230V connector/adaptor by pinching hard on the retaining 

tabs on either side and pulling firmly upward.

3) Install the 115V connector/adaptor (provided in the installation kit) by 

inserting it firmly into the adaptor receptacle. Note that the connector/

adaptor is keyed so that it cannot be installed backwards. Ensure that the 

retaining tabs have locked into position.

4) Replace the input wiring cover.

Important:

 Although the internal AC wiring is protected by the front panel 

mounted circuit breaker, the wiring to the PM must also be protected by 

plugging into an appropriate over-current protected three prong outlet 

or routed through a separate dedicated fuse or circuit breaker on an AC 

distribution panel with proper safety/earth chassis ground in accordance 

with all applicable codes and ordinances.

AC Input Wiring 
Compartment Cover

Remove these screws for access

AC Input Connector/Adaptor
             (115V or 230V)

AC Input Terminal 

Wiring

 HOT     GND    NEUT

   (LEFT)        (CENTER)      (RIGHT)

Содержание PM-12-40

Страница 1: ...ther Factors 3 III INSTALLATION 3 A Materials Provided 4 B Mounting 4 C AC Input Wiring and Voltage Selection 4 D DC Output Wiring 5 E Parallel Wiring 6 F Chassis Grounding 6 IV OPERATION 7 A AC Input...

Страница 2: ...FIGURE 3 Power Module Rear Panel 1 000 watt models PM 12 45 only FIGURE 1 Power Module Front Panel all models Cooling Fans Page 7 Output Voltage Adjustment Pot Pages 7 8 Output Voltage Test Points Pa...

Страница 3: ...of miles from the strike point Equipment generated transient sources include utility fault conditions and load switching as well as on site equipment such as pumps and air conditioning loads motors ph...

Страница 4: ...d Blue AC Neutral Green AC Ground safety earth may be Green with Yellow Stripe Input Voltage Selection As shipped from the factory the PM is set up for 230V AC input For 115V AC applications set the r...

Страница 5: ...instead if the application requires it see V2 below V OUT Terminal This output is routed through an internal or ing isolation diode This terminal should be used for most installations Use of this ter...

Страница 6: ...output voltage 4 Shut off the PM turn on the next unit in the system and repeat steps 2 through 4 until all PM s in the system have the identical V OUT output voltage Method 2 1 With all Power Modules...

Страница 7: ...g circuit of the PM should prevent these fuses from blowing under normal operating conditions If the d c fuse s blow this may indicate a reverse polarity hook up or an internal short Always disconnect...

Страница 8: ...0V DC V Options Available from the Factory A Charger Function Board Installed on Model PM 12 45 The PM can be factory modified with the installation of a charger function board If the PM has already b...

Страница 9: ...out of modules for repair or replacement The kit consists of two wiring harness one for positive and negative DC output wiring another for alarm contact wiring Wires are pre cut to proper length all n...

Страница 10: ...n If breaker continues to trip contact factory 2 Return to place of purchase for repair re placement or contact NEWMAR for return authorization Replace output fuse If fuse blows again return to place...

Отзывы: