NewMar Phase Three PT-CE Series Скачать руководство пользователя страница 14

CONDITION

POSSIBLE CAUSE

SOLUTION

VI) TROUBLESHOOTING (cont.)

3. Charger output is not
properly connected to
batteries.

3. Refer to d.c. wiring
installation diagram for
proper connection to
batteries.

4. Blown output fuse

4. Replace with another of
correct value (see section
III D, “d.c. output Wiring”)

5. Defective charger.

5. Return for analysis/
repair by servicing dealer
where charger was
purchased or contact
NEWMAR for Return
Authorization Number.

D. Charger repeatedly
blows input fuse with no
batteries connected.

Internal short.

Same as above.

E. Reverse polarity
connection to charger has
caused charger to stop
charging.

d.c. Output fuse and
possibly other
components blown.

Replace output fuse with
another of correct value. If
fuse again blows, return to
servicing dealer or contact
NEWMAR for Return
Authorization Number.

F. High output voltage
measured across charger
output terminals.

1. Batteries not connected
to charger. It is normal to
read 1/2 volt higher across
any output bank when no
batteries are connected.

1. Check for tight
connection of charging
leads from charger to
batteries.

2. Equalize function
activated

2. Check to verify proper
installation and operation
of equalize timer

G. Charger will not stay in
bulk/absorption mode
when re-initialize button
on remote panel pressed

Batteries at or nearing full
charge (Not a problem
condition)

Verify proper operation by
pressing reinitialize button
(on optional remote panel)
and applying a  large d.c.
load

C. Charger does not
charge. (continued)

VII) SPECIFICATIONS

INPUT RANGE (ALL MODELS): 85-135/170-270V a.c. (via selector switch or a.c.
input connector/adaptor); 47-63 HZ (automatic)
Derate Models, PT24-20CE and PT-40CE from 560 watts @ 95V a.c. to 500 watts
@ 85V a.c.

OUTPUT BANKS (ALL MODELS): 3

OUTPUT VOLTAGES WITHOUT TEMPERATURE COMPENSATION OPTION:

        12 VOLT MODELS

    24 VOLT MODELS

Charge

Float

Charge

Float

Setting

@ 50 % load

@ .1 amp load

@ 50 % load

@ .1 amp load

Gel-Cell

14.0V d.c.

13.6V d.c.

28.0V d.c.

27.2V d.c.

Lead Acid

14.2V d.c.

13.4V d.c

28.4V d.c.

26.8V d.c.

TEMPERATURE COMPENSATION:

- 3 mV per cell per ° F

- 5 mV per cell per ° C

TEMPERATURE RATINGS:
-40°C to + 60°C; Derate linearly from 100 % @ 50°C to 75 % @ 60°C

PROTECTION: Input fuse; Output fuse for reverse polarity protection; Current
limiting; Automatic high temperature power reduction; Time and load controlled
high rate charge circuit; Ignition protected

  

Model

Input Amps

       Output

  Weight

115/230V

Volts        Amps (Cont.)

Lbs.   Kg.

PT-20CE

4.3 / 2.2

12

  20

11        5

PT-40CE

8.5 / 4.3

12

  40

12       5.5

PT-70CE

16 / 8

12

  70

24      10.9

PT-24-20CE

8.5 / 4.3

24

  20

12       5.5

PT-24-35CE

16 / 8

24

  35

24      10.9

INPUT/OUTPUT FUSE VALUES:

Model

            a.c. Input Fuse

d.c. Output Fuse

115V a.c

230V a.c.

PT-20CE

AGC-6

AGC-3

(1 ea.) ATC-30

PT-40CE

ABC-12

AGC-6

(2 ea.) ATC-30

PT-70CE

ABC 20

ABC-12

(1 ea.) HBO-100

PT-24-20CE

ABC-12

AGC-6

(1 ea.) ATC-30

PT-24-35CE

ABC-20

ABC-12

(2 ea.) ATC-30

26

27

All manuals and user guides at all-guides.com

Содержание Phase Three PT-CE Series

Страница 1: ...y does not apply to damage through accident negligence misuse abuse or normal wear and tear Further this warranty does not cover products that have been altered or modified from their original sale co...

Страница 2: ...detailed later in this manual Three step smart charging bulk absorption float Gel cell lead acid switch selects optimum charge float voltages based on battery type Multiple output banks charge indepen...

Страница 3: ...wise damaged take it to a qualified serviceman 11 Do not disassemble the charger take it to a qualified serviceman when service or repair is necessary Incorrect reassembly may result in a risk of elec...

Страница 4: ...D CABLE CLAMP except PT 70CE and PT 24 35CE 1 INPUT POWER CORD STRAIN RELIEF PT 70CE and PT 24 35CE only 1 INPUT FUSE FOR 115V a c APPLICATIONS 230V a c FUSE INSTALLED 1 a c INPUT WIRING COVER PT 70CE...

Страница 5: ...ified service personnel should access the output terminals of the charger Pull off the black plastic terminal cover at the bottom of the front panel to expose the d c output terminals and attach d c w...

Страница 6: ...ng conditions If the d c fuse s blow this may indicate a reverse polarity hook up or an internal short Always disconnect a c to the charger before checking fuses To check or replace the d c fuse the c...

Страница 7: ...reen or Green with Yellow Stripe a c Ground safety earth As shipped from the factory the charger is set up for 230V a c input For 115V a c applications you must 1 Slide the recessed 115 230 input sele...

Страница 8: ...se Replacement The a c input of your charger is protected by an input fuse The input fuseholder is located near the bottom of the unit on the left side 20 and 40 amp models or on the bottom of the uni...

Страница 9: ...remote panel Note The PT CE charger is able to deliver its full rated output current while in the float mode Installation Note The time out circuit of the PT CE charger has been set at about 8 10 hou...

Страница 10: ...ng in excessive loss of electrolyte Conversely if the batteries are in a consistently cool environment they may be chronically undercharged resulting in sulfation of the battery plates Either of these...

Страница 11: ...er function plug in PCB which is located on the right side of the charger Locate TP1 and TP2 4 Route the two control wires of the timer through the bottom of the cover assembly and solder the ends to...

Страница 12: ...he lower left hand corner of the charger front panel B Constant Versus Occasional Use In general it is recommended that the charger be left connected continuously to the a c distribution system so tha...

Страница 13: ...cing power output 3 Clean or replace clogged fan filter or replace fan if necessary B Charger continues to charge at 3 amps or more does not taper back in charge 1 d c load still connected to batterie...

Страница 14: ...a problem condition Verify proper operation by pressing reinitialize button on optional remote panel and applying a large d c load C Charger does not charge continued VII SPECIFICATIONS INPUT RANGE AL...

Страница 15: ...s and scrub the battery with a baking soda solution Rinse with fresh water and dry with a clean cloth You may wish to purchase a set of terminal post corrosion prevention rings These are alkali satura...

Страница 16: ...an accurate voltage reading on the output of the charger with no batteries attached This is checked merely to ensure that you do not have an open circuit on the output The battery charger has a therm...