If the product is installed inside a wall or a cabinet, in addition to the
preceding requirements, the ventilation area around the bottom, top
and two sides must be at least 50% of the sealing surface to ensure
proper ventilation.
Installation Requirement
You can install the product in an unfixed or a wall
-
mounted way based
on your needs. The wall
-
mounted way can save a large amount of
space.
If the product is installed in an unfixed way, use the designated hanger
or holder. If you want to use a self
-
made hanger or holder, ensure
that the bearing capacity of it is at least four times of the weight of the
product, and the product is installed stably on it.
If the product is installed in a wall
-
mounted way, the bearing capacity
of the surface for installation must be at least four times of the weight
of the product. If the surface for installation is the wall or the ceiling of
a building, the surface must be made of solid bricks, concrete or other
materials with equal intensity. If the product is installed on a surface
made of loose material such as an old brick wall, wood plank wall, solid
brick wall, or a metal or non
-
metal structure surface, or a surface with
a thick decoration layer, take necessary consolidating measures to
ensure that the product is stably installed.
Ventilation
requirements
Distance to the surface for installation (cm)
Nominal power
Left and
right sides
Top
Bottom
Back
Greater than 100 W
10
20
20
10
Bearing
Ventilation