background image

 

                                                                                                                                                                                             

Enter Setup

 

 

9                                                                                                                                                                                              *

* Exit Setup

 

 

Top View

 

 

 

Содержание NLS-HR3290

Страница 1: ...NLS HR3290 Corded 2D Barcode Scanner User Guide...

Страница 2: ...unction or design at any time without notice The information contained herein is subject to change without prior notice The products depicted in this manual may include software copyrighted by Fujian...

Страница 3: ...Check Digit and Transmit Code 32 Start Stop Character features in Chapter 8 5 Added Chapter 10 Data Formatter and Chapter 11 Batch Programming 6 Changed the default settings of the following paramete...

Страница 4: ...tion Cable 6 Power On Sleep Power Off Reboot 7 Maintenance 7 Dimensions unit mm 8 Left View 8 Front View 8 Top View 9 Scanning Instructions 10 Barcode Programming 11 Factory Defaults 12 Custom Default...

Страница 5: ...urePOS Tabletop 30 IBM SurePOS Handheld 30 Chapter 3 Scan Mode 31 Manual Mode 31 Decode Session Timeout 31 Level Trigger Pulse Trigger 32 Auto Sleep 32 Timeout between Decodes Same Barcode 33 Sense Mo...

Страница 6: ...GR Not Good Read Message 48 Edit NGR Message 48 Chapter 7 Prefix Suffix 49 Global Settings 50 Enable Disable All Prefixes Suffixes 50 Prefix Sequences 50 Custom Prefix 51 Enable Disable Custom Prefix...

Страница 7: ...le Disable EAN 8 64 Transmit Check Digit 64 Add On Code 65 Add On Code Required 66 EAN 8 Extension 66 EAN 13 67 Restore Factory Defaults 67 Enable Disable EAN 13 67 Transmit Check Digit 67 Add On Code...

Страница 8: ...tore Factory Defaults 80 Enable Disable UPC A 80 Transmit Check Digit 80 Add On Code 81 Add On Code Required 81 Transmit Preamble Character 82 Interleaved 2 of 5 83 Restore Factory Defaults 83 Enable...

Страница 9: ...sable Code 39 Full ASCII 96 Enable Disable Code 32 97 Code 32 Prefix 97 Transmit Code 32 Check Digit 98 Transmit Code 32 Start Stop Character 98 Codabar 99 Restore Factory Defaults 99 Enable Disable C...

Страница 10: ...1 PDF 417 111 Restore Factory Defaults 111 Enable Disable PDF 417 111 Set Length Range for PDF 417 111 PDF 417 Twin Code 112 Character Encoding 112 QR Code 113 Restore Factory Defaults 113 Enable Disa...

Страница 11: ...ple Data Formats 127 Data Format Selection 127 Change Data Format for a Single Scan 128 Clear Data Format 129 Query Data Formats 129 Formatter Command Type 6 130 Send Commands 130 Move Commands 133 Se...

Страница 12: ...ode ID 168 k Program the NGR Message 168 l Program the Code Page 169 m Program the Length Range Maximum Minimum Lengths for a Symbology 169 n Program the Custom Inter keystroke Delay 170 o Program the...

Страница 13: ...rTM RSS Limited Stacked Expanded versions It can read barcodes on virtually any medium paper plastic card mobile phones and LCD displays About This Guide This guide provides programming instructions f...

Страница 14: ...Enter Setup Exit Setup 2 HR3290 Scanner Decode LED Red Scanner is powered on Green Barcode is decoded successfully...

Страница 15: ...RS 232 7 PC_DATA CTS I O PC data signal Clear to send RS 232 8 GND P Ground 9 D I O USB signal 10 D I O Connecting the Scanner to a Host The scanner must be connected to a Host in actual application...

Страница 16: ...Setup 4 Using USB Cable Connect the scanner to a Host through a USB cable with RJ45 and USB connectors 1 Plug the RJ45 connector into the data port on the scanner 2 Plug the USB connector into the USB...

Страница 17: ...Host through an RS 232 cable with RJ45 RS 232 and power connectors 1 Plug the RJ45 connector into the data port on the scanner 2 Plug the RS 232 connector into the RS 232 port on the Host 3 Connect t...

Страница 18: ...a straightened paper clip and then follow the steps below 1 Disconnect the power adaptor from mains if there is one 2 Insert the needle into the hole 3 Pull out the cable slowly from the scanner whil...

Страница 19: ...tion cable from the Host or disconnect the power adaptor from mains Reboot the scanner If the scanner stops responding to input or runs abnormally turn off the scanner and then turn it back on Mainten...

Страница 20: ...Enter Setup Exit Setup 8 Dimensions unit mm Left View Front View...

Страница 21: ...Enter Setup 9 Exit Setup Top View...

Страница 22: ...aiming beam 2 Aim the red beam across the center of barcode as shown below 3 Release the Trigger when the red beam goes off If the barcode is decoded successfully the scanner will emit a good read bee...

Страница 23: ...mming barcodes such as the Enter Setup barcode and Restore All Factory Defaults barcode can be read Enter Setup Exit Setup Programming barcode data can be transmitted to the Host Scan the appropriate...

Страница 24: ...ve the current settings as custom defaults Once custom default settings are stored they can be recovered at any time by scanning the Restore All Custom Defaults barcode Custom defaults are stored in t...

Страница 25: ...The scanner provides a TTL 232 interface and a USB interface to communicate with the host device The host device can receive scanned data and send commands to control the scanner or to access alter th...

Страница 26: ...Moreover you need to set communication parameters including baud rate parity check data bit and stop bit to match the host device RS 232 Default serial communication parameters are listed below Make s...

Страница 27: ...Enter Setup 15 Exit Setup Baud Rate Baud rate is the number of bits of data transmitted per second Set the baud rate to match the Host requirements 9600 1200 19200 2400 38400 4800 57600 14400 115200...

Страница 28: ...to 7 you can only select either Even Parity or Odd Parity The None option will be regarded as Even Parity in this case None Even Parity Odd Parity Data Bit When the number of data bits is set to 7 yo...

Страница 29: ...Enter Setup 17 Exit Setup Data Bit Parity Check 7 Data Bits Even Parity 7 Data Bits Odd Parity 8 Data Bits No Parity 8 Data Bits Even Parity 8 Data Bits Odd Parity Stop Bit 1 Stop Bit 2 Stop Bits...

Страница 30: ...ation using 00000000 disables the host device from distinguishing between scanners of same model USB HID KBW When you connect the scanner to the host device via a USB connection you can enable the USB...

Страница 31: ...Setup 19 Exit Setup Polling Rate This parameter specifies the polling rate for a USB keyboard If the Host drops characters change the polling rate to a bigger value 1ms 2ms 3ms 4ms 5ms 6ms 7ms 8ms 9ms...

Страница 32: ...Enter Setup Exit Setup 20 USB Country Keyboard Types Keyboard layouts vary from country to country The default setting is U S keyboard U S Belgium Brazil Canada Czechoslovakia Denmark Finland France...

Страница 33: ...Enter Setup 21 Exit Setup Germany Austria Greece Hungary Israel Italy Latin America South America Netherlands Norway Poland Portugal...

Страница 34: ...up 22 Romania Russia Slovakia Spain Sweden Switzerland Turkey_F Turkey_Q UK Japan Note To program the scanner to get proper output for Russian encoded with Windows 1251 or UTF 8 PDF417 QR Code Data Ma...

Страница 35: ...barcode below to enable or disable the emission of beep when an unknown character is detected Beep on Unknown Character Do Not Beep on Unknown Character Inter Keystroke Delay This parameter specifies...

Страница 36: ...ow to convert barcode data to your desired case No Case Conversion Invert Upper and Lower Case Characters Convert All to Upper Case Convert All to Lower Case Example When the Invert Upper and Lower Ca...

Страница 37: ...ed keyboard type but falling into 0x20 0xFF are sent in the ALT Keypad way Mode 2 ASCII characters falling into 0x20 0xFF are sent in the ALT Keypad way Mode 3 ASCII characters falling into 0x00 0xFF...

Страница 38: ...tion characters 0x00 0x1F are sent as ASCII sequences over the keypad For more information see Appendix 8 ASCII Function Key Mapping Table Example Barcode data 0x16 Enable Function Key Mapping Ctrl V...

Страница 39: ...ke _ and is still emulated as keystrokes on main keyboard Do Not Emulate Numeric Keypad Emulate Numeric Keypad Code Page The Code Page programming feature is provided to support more international cha...

Страница 40: ...interface is recommended for new application programs It can send up to 56 characters in a single USB report and appears more efficient than keyboard emulation Features HID based no custom driver requ...

Страница 41: ...erfaces go to www USB org Acquire Scanned Data After scanning and decoding a barcode the scanner sends the following input report Bit Byte 7 6 5 4 3 2 1 0 0 Report ID 0x02 1 Length of the barcode 2 57...

Страница 42: ...gned by USB Implementers Forum Newland s vendor ID is 1EAB Hex A PID is assigned to each interface Product Interface PID Hex PID Dec HR3290 USB HID KBW 1A03 6659 USB COM Port Emulation 1A06 6662 USB H...

Страница 43: ...ded or you release the trigger or decode session timeout expires Manual Mode Decode Session Timeout This parameter sets the maximum time decode session continues during a scan attempt It is programmab...

Страница 44: ...erformed for a time period user programmable When the scanner is in the sleep mode pressing the Trigger or receiving command from the host device can awake the scanner The scanner returns to full oper...

Страница 45: ...Do not allow the scanner to re read same barcode before the timeout between decodes same barcode expires Disable Timeout between Decodes Allow the scanner to re read same barcode The following parame...

Страница 46: ...a trigger pull can also activate a decode session The decode session continues until the barcode is decoded or the trigger is released When the session ends the scanner continues to monitor ambient i...

Страница 47: ...anner starts next decode session after a good read Pause after Good Read The scanner starts another round of illumination monitoring and image stabilization after a good read Timeout between Decodes T...

Страница 48: ...Do not allow the scanner to re read same barcode before the timeout between decodes same barcode expires Disable Timeout between Decodes Allow the scanner to re read same barcode Disable Timeout betw...

Страница 49: ...ironment Medium Sensitivity Low Sensitivity High Sensitivity Enhanced Sensitivity If the above four options fail to meet your needs you may program the threshold value of illumination change Illuminat...

Страница 50: ...mpt It is programmable in 1ms increments from 100ms to 3 600 000ms The default setting is 3 000ms To learn how to program this parameter see Appendix 5 Decode Session Timeout Timeout between Decodes T...

Страница 51: ...Do not allow the scanner to re read same barcode before the timeout between decodes same barcode expires Disable Timeout between Decodes Allow the scanner to re read same barcode Disable Timeout betw...

Страница 52: ...its field of view from the center to the periphery and transmits the barcode that has been first decoded Whole Area Decoding Specific Area Decoding The scanner attempts to read barcode s within a spec...

Страница 53: ...white box is the decoding area Since Barcode 1 passes through the decoding area it will be read Barcode 2 does not pass through the decoding area so it will not be read You can define the decoding ar...

Страница 54: ...Enter Setup Exit Setup 42 Top of Decoding Area Bottom of Decoding Area Left of Decoding Area Right of Decoding Area...

Страница 55: ...umination options are provided to improve the lighting conditions during every image capture Normal Illumination LEDs are turned on during image capture Always ON Illumination LEDs keep ON after the s...

Страница 56: ...llows positioning the target barcode within its field of view and thus makes decoding easier Normal The scanner projects an aiming pattern only during barcode scanning capture Always ON Aiming pattern...

Страница 57: ...e Startup Beep Disable Startup Beep Good Read Beep for Non programming Barcode Scan the appropriate barcode below to enable or disable the emission of beep when a non programming barcode is decoded Be...

Страница 58: ...Enter Setup Exit Setup 46 Beep Type Type 1 Type 3 Type 2 Beep Volume Loud Low Medium...

Страница 59: ...lt the scanner fails to transmit the unknown characters Scan the appropriate barcode below to enable or disable the emission of beep when an unknown character is detected Beep on Unknown Character Do...

Страница 60: ...n a barcode cannot be decoded Transmit NGR Message Do Not Transmit NGR Message Edit NGR Message To edit an NGR message scan the Edit NGR Message barcode and the numeric barcodes corresponding to the A...

Страница 61: ...can also be the alternatives Data editing may include Append AIM ID Code ID custom prefix before the decoded data Append custom suffix after the decoded data Append terminating character to the end of...

Страница 62: ...ta with no prefix suffix Enable All Prefixes Suffixes Allow user to append Code ID prefix AIM ID prefix custom prefix suffix and terminating character to the barcode data before the transmission Enabl...

Страница 63: ...ble Custom Prefix Set Custom Prefix To set a custom prefix scan the Set Custom Prefix barcode and the numeric barcodes representing the hexadecimal value s of a desired prefix and then scan the Save b...

Страница 64: ...er will add the symbology identifier before the scanned data after decoding Enable AIM ID Prefix Disable AIM ID Prefix Code ID Code ID can also be used to identify barcode type Unlike AIM ID Code ID i...

Страница 65: ...and then scan the Save barcode Refer to Appendix 4 ASCII Table for hexadecimal values of characters To view a setting example see Appendix 5 Parameter Programming Examples Modify PDF417 Code ID Modify...

Страница 66: ...y UPC A Code ID Modify ISBN Code ID Modify ISSN Code ID Modify Code 39 Code ID Modify Code 93 Code ID Modify Interleaved 2 of 5 Code ID Modify ITF 14 Code ID Modify ITF 6 Code ID Modify Codabar Code I...

Страница 67: ...Enter Setup 55 Exit Setup Modify Standard 25 Code ID Modify Matrix 25Code ID Modify COOP 25 Code ID Modify Code 11 Modify Plessey Code ID Modify MSI Plessey Code ID Modify GS1 Databar Code ID...

Страница 68: ...ble Custom Suffix Set Custom Suffix To set a custom suffix scan the Set Custom Suffix barcode and the numeric barcodes representing the hexadecimal value s of a desired prefix and then scan the Save b...

Страница 69: ...of data which means nothing can be added after it A terminating character suffix can contain 1 7 characters Enable Disable Terminating Character Suffix To enable disable terminating character suffix s...

Страница 70: ...LF 0x0D 0x0A To set a terminating character suffix scan the Set Terminating Character Suffix barcode and the numeric barcodes representing the hexadecimal value s of a desired terminating character an...

Страница 71: ...programming barcodes Enable All Symbologies Disable All Symbologies Enable Disable 1D Symbologies If the Disable 1D Symbologies feature is enabled the scanner will not be able to read any 1D barcodes...

Страница 72: ...The examples of regular barcode and inverse barcode are shown below Regular Barcode Inverse Barcode Video Reverse allows the scanner to read barcodes that are inverted Video Reverse ON Read both regu...

Страница 73: ...p 1D Symbologies Code 128 Restore Factory Defaults Restore the Factory Defaults of Code 128 Enable Disable Code 128 Enable Code 128 Disable Code 128 Set Length Range for Code 128 Set the Minimum Lengt...

Страница 74: ...up 62 GS1 128 UCC EAN 128 Restore Factory Defaults Restore the Factory Defaults of GS1 128 Enable Disable GS1 128 Enable GS1 128 Disable GS1 128 Set Length Range for GS1 128 Set the Minimum Length Set...

Страница 75: ...Exit Setup AIM 128 Restore Factory Defaults Restore the Factory Defaults of AIM 128 Enable Disable AIM 128 Enable AIM 128 Disable AIM 128 Set Length Range for AIM 128 Set the Minimum Length Set the M...

Страница 76: ...the Factory Defaults of EAN 8 Enable Disable EAN 8 Enable EAN 8 Disable EAN 8 Transmit Check Digit EAN 8 is 8 digits in length with the last one as its check digit used to verify the integrity of the...

Страница 77: ...e Enable 2 Digit Add On Code Disable 2 Digit Add On Code Enable 5 Digit Add On Code Disable 5 Digit Add On Code Enable 2 Digit Add On Code Enable 5 Digit Add On Code The scanner decodes a mix of EAN 8...

Страница 78: ...EAN 8 barcodes that contain add on codes EAN 8 Add On Code Required EAN 8 Add On Code Not Required EAN 8 Extension Disable EAN 8 Zero Extend Transmit EAN 8 barcodes as is Enable EAN 8 Zero Extend Add...

Страница 79: ...xit Setup EAN 13 Restore Factory Defaults Restore the Factory Defaults of EAN 13 Enable Disable EAN 13 Enable EAN 13 Disable EAN 13 Transmit Check Digit Transmit EAN 13 Check Digit Do Not Transmit EAN...

Страница 80: ...e scanner decodes a mix of EAN 13 barcodes with and without 2 digit 5 digit add on codes Disable 2 Digit Add On Code Disable 5 Digit Add On Code The scanner decodes EAN 13 and ignores the add on code...

Страница 81: ...on your selection for the Add On Code Required feature Do Not Require Add On Code Require Add On Code EAN 13 Beginning with 378 379 Add On Code Required This setting programs the scanner to require an...

Страница 82: ...depending on your selection for the Add On Code Required feature Do Not Require Add On Code Require Add On Code EAN 13 Beginning with 434 439 Add On Code Required This setting programs the scanner to...

Страница 83: ...depending on your selection for the Add On Code Required feature Do Not Require Add On Code Require Add On Code EAN 13 Beginning with 978 Add On Code Required This setting programs the scanner to req...

Страница 84: ...that begin with 979 must have a 2 digit or 5 digit add on code The EAN 13 barcode with the add on code is then transmitted If the required add on code is not found the EAN 13 barcode is discarded Do N...

Страница 85: ...Enter Setup 73 Exit Setup ISSN Restore Factory Defaults Restore the Factory Defaults of ISSN Enable Disable ISSN Enable ISSN Disable ISSN...

Страница 86: ...Code The scanner decodes a mix of ISSN barcodes with and without 2 digit 5 digit add on codes Disable 2 Digit Add On Code Disable 5 Digit Add On Code The scanner decodes ISSN and ignores the add on co...

Страница 87: ...Enter Setup 75 Exit Setup ISBN Restore Factory Default Restore the Factory Defaults of ISBN Enable Disable ISBN Enable ISBN Disable ISBN Set ISBN Format ISBN 13 ISBN 10...

Страница 88: ...Code The scanner decodes a mix of ISBN barcodes with and without 2 digit 5 digit add on codes Disable 2 Digit Add On Code Disable 5 Digit Add On Code The scanner decodes ISBN and ignores the add on co...

Страница 89: ...77 Exit Setup UPC E Restore Factory Defaults Restore the Factory Defaults of UPC E Enable Disable UPC E Enable UPC E Disable UPC E Transmit Check Digit Transmit UPC E Check Digit Do Not Transmit UPC E...

Страница 90: ...The scanner decodes a mix of UPC E barcodes with and without 2 digit 5 digit add on codes Disable 2 Digit Add On Code Disable 5 Digit Add On Code The scanner decodes UPC E and ignores the add on code...

Страница 91: ...code is the system character 0 Transmit System Character 0 Do Not Transmit System Character 0 UPC E Extension Disable UPC E Extend Transmit UPC E barcodes as is Enable UPC E Extend Extend UPC E barcod...

Страница 92: ...Exit Setup 80 UPC A Restore Factory Defaults Restore the Factory Defaults of UPC A Enable Disable UPC A Enable UPC A Disable UPC A Transmit Check Digit Transmit UPC A Check Digit Do Not Transmit UPC A...

Страница 93: ...The scanner decodes a mix of UPC A barcodes with and without 2 digit 5 digit add on codes Disable 2 Digit Add On Code Disable 5 Digit Add On Code The scanner decodes UPC A and ignores the add on code...

Страница 94: ...and System Character can be transmitted as part of a UPC A barcode Select one of the following options for transmitting UPC A preamble to the host device transmit system character only or transmit sys...

Страница 95: ...store Factory Defaults Restore the Factory Defaults of Interleaved 2 of 5 Enable Disable Interleaved 2 of 5 Enable Interleaved 2 of 5 Disable Interleaved 2 of 5 Set Length Range for Interleaved 2 of 5...

Страница 96: ...d 2 of 5 barcodes to verify that the data complies with the check digit algorithm Barcodes passing the check will be transmitted except the last digit whereas those failing it will not be transmitted...

Страница 97: ...re is available only when USB HID KBW is enabled Transmit Delay per Character applies to both Expanded and Unexpanded Febraban while Transmit Delay per 12 Characters applies to Expanded Febraban only...

Страница 98: ...t values must have a leading zero See Appendix 5 for more information The default value is 70ms Custom Transmit Delay per 12 Characters To set this parameter scan the Custom Transmit Delay per 12 Char...

Страница 99: ...length of 14 characters and the last character as the check digit Restore the Factory Defaults of ITF 14 Disable ITF 14 Enable ITF 14 But Do Not Transmit Check Digit Enable ITF 14 and Transmit Check D...

Страница 100: ...a length of 6 characters and the last character as the check digit Restore the Factory Defaults of ITF 6 Disable ITF 6 Enable ITF 6 But Do Not Transmit Check Digit Enable ITF 6 and Transmit Check Digi...

Страница 101: ...2 of 5 Restore Factory Defaults Restore the Factory Defaults of Matrix 2 of 5 Enable Disable Matrix 2 of 5 Enable Matrix 2 of 5 Disable Matrix 2 of 5 Set Length Range for Matrix 2 of 5 Set the Minimu...

Страница 102: ...Enter Setup Exit Setup 90 Check Digit Verification Disable Do Not Transmit Check Digit After Verification Transmit Check Digit After Verification...

Страница 103: ...Restore Factory Defaults Restore the Factory Defaults of Industrial 2 of 5 Enable Disable Industrial 2 of 5 Enable Industrial 2 of 5 Disable Industrial 2 of 5 Set Length Range for Industrial 2 of 5 Se...

Страница 104: ...Enter Setup Exit Setup 92 Check Digit Verification Disable Transmit Check Digit After Verification Do Not Transmit Check Digit After Verification...

Страница 105: ...2 of 5 IATA 2 of 5 Restore Factory Defaults Restore the Factory Defaults of Standard 25 Enable Disable Standard 25 Enable Standard 25 Disable Standard 25 Set Length Range for Standard 25 Set the Mini...

Страница 106: ...Enter Setup Exit Setup 94 Check Digit Verification Disable Transmit Check Digit After Verification Do Not Transmit Check Digit After Verification...

Страница 107: ...Code 39 Restore Factory Defaults Restore the Factory Defaults of Code 39 Enable Disable Code 39 Enable Code 39 Disable Code 39 Transmit Start Stop Character Transmit Start Stop Character Do not Trans...

Страница 108: ...Digit Verification Disable Transmit Check Digit After Verification Do Not Transmit Check Digit After Verification Enable Disable Code 39 Full ASCII The scanner can be configured to identify all ASCII...

Страница 109: ...ble Code 32 Code 39 must be enabled and Code 39 check digit verification must be disabled for this parameter to function Disable Code 32 Enable Code 32 Code 32 Prefix Scan the appropriate bar code bel...

Страница 110: ...led for this parameter to function Do Not Transmit Code 32 Check Digit Transmit Code 32 Check Digit Transmit Code 32 Start Stop Character Code 32 must be enabled for this parameter to function Do Not...

Страница 111: ...Exit Setup Codabar Restore Factory Defaults Restore the Factory Defaults of Codabar Enable Disable Codabar Enable Codabar Disable Codabar Set Length Range for Codabar Set the Minimum Length Set the M...

Страница 112: ...100 Check Digit Verification Disable Transmit Check Digit After Verification Do Not Transmit Check Digit After Verification Transmit Start Stop Character Transmit Start Stop Character Do not Transmit...

Страница 113: ...Format You can choose your desired start stop character format by scanning the appropriate barcode below ABCD ABCD as the Start Stop Character ABCD TN E as the Start Stop Character Start Stop Characte...

Страница 114: ...it Setup 102 Code 93 Restore Factory Defaults Restore the Factory Defaults of Code 93 Enable Disable Code 93 Enable Code 93 Disable Code 93 Set Length Range for Code 93 Set the Minimum Length Set the...

Страница 115: ...Enter Setup 103 Exit Setup Check Digit Verification Disable Do Not Transmit Check Digit After Verification Transmit Check Digit After Verification...

Страница 116: ...store Factory Defaults Restore the Factory Defaults of GS1 Databar Enable Disable GS1 Databar Enable GS1 DataBar Disable GS1 DataBar Transmit Application Identifier 01 Transmit Application Identifier...

Страница 117: ...5 Exit Setup Code 11 Restore Factory Defaults Restore the Factory Defaults of Code 11 Enable Disable Code 11 Enable Code 11 Disable Code 11 Set Length Range for Code 11 Set the Minimum Length Set the...

Страница 118: ...Do Not Transmit Check Digit Check Digit Verification Disable One Check Digit MOD11 Two Check Digits MOD11 MOD11 Two Check Digits MOD11 MOD9 One Check Digit MOD11 Len 10 Two Check Digits MOD11 MOD11 Le...

Страница 119: ...7 Exit Setup Plessey Restore Factory Defaults Restore the Factory Defaults of Plessey Enable Disable Plessey Enable Plessey Disable Plessey Set Length Range for Plessey Set the Minimum Length Set the...

Страница 120: ...Enter Setup Exit Setup 108 Check Digit Verification Disable Do Not Transmit Check Digit After Verification Transmit Check Digit After Verification...

Страница 121: ...MSI Plessey Restore Factory Defaults Restore the Factory Defaults of MSI Plessey Enable Disable MSI Plessey Enable MSI Plessey Disable MSI Plessey Set Length Range for MSI Plessey Set the Minimum Len...

Страница 122: ...Setup Exit Setup 110 Transmit Check Digit Transmit Check Digit Do Not Transmit Check Digit Check Digit Verification Disable One Check Digit MOD10 Two Check Digits MOD10 MOD10 Two Check Digits MOD10 M...

Страница 123: ...etup 2D Symbologies PDF 417 Restore Factory Defaults Restore the Factory Defaults of PDF 417 Enable Disable PDF 417 Enable PDF 417 Disable PDF 417 Set Length Range for PDF 417 Set the Minimum Length S...

Страница 124: ...pecifications and be placed closely together There are 3 options for reading PDF417 twin codes Single PDF417 Only Read either PDF417 code Twin PDF417 Only Read both PDF417 codes Both Single Twin Read...

Страница 125: ...Restore Factory Defaults Restore the Factory Defaults of QR Code Enable Disable QR Code Enable QR Code Disable QR Code Set Length Range for QR Code Set the Minimum Length Set the Maximum Length Micro...

Страница 126: ...ave similar specifications and be placed closely together There are 3 options for reading QR twin codes Single QR Only Read either QR code Twin QR Only Read both QR codes Both Single Twin Read both QR...

Страница 127: ...Data Matrix Restore Factory Defaults Restore the Factory Defaults of Data Matrix Enable Disable Data Matrix Enable Data Matrix Disable Data Matrix Set Length Range for Data Matrix Set the Minimum Len...

Страница 128: ...Enter Setup Exit Setup 116 Rectangular Barcode Enable Rectangular Barcode Disable Rectangular Barcode Mirror Image Decode Mirror Images Do Not Decode Mirror Images...

Страница 129: ...Matrix twin codes Single Data Matrix Only Read either Data Matrix code Twin Data Matrix Only Read both Data Matrix codes Transmission order Data Matrix code on the left in the upper position followed...

Страница 130: ...Factory Defaults Restore the Factory Defaults of Chinese Sensible Code Enable Disable Chinese Sensible Code Enable Chinese Sensible Code Disable Chinese Sensible Code Set Length Range for Chinese Sen...

Страница 131: ...mage captured by the scanner to meet actual need by scanning the appropriate barcode on the next page The following figures illustrate original image and three flipped images Original Image Image Flip...

Страница 132: ...xit Setup 120 Flip Do Not Flip Flip Vertically Flip Horizontally Flip Horizontally and Vertically Flip Vertically Flip Vertically Do Not Flip Vertically Flip Horizontally Flip Horizontally Do Not Flip...

Страница 133: ...size of formatter commands in a data format is 112 characters By default the data formatter is disabled Enable it when required If you have changed data format settings and wish to clear all formats a...

Страница 134: ...d type Specify what type of formatter commands will be used Scan a numeric barcode 6 to select formatter command type 6 See the Formatter Command Type 6 section in this chapter for more information St...

Страница 135: ..._0 using formatter command type 6 Code 128 containing 10 characters applicable send all characters followed by A 1 Scan the Enter Setup barcode Enter the Setup mode 2 Scan the Add Data Format barcode...

Страница 136: ...d to edit data max 112 characters For more information see the Formatter Command Type 6 section Note A batch command used to create a data format must conform to the syntax above Returned value 0x06 i...

Страница 137: ...ingly and gets outputted without prefixes and suffixes even if prefix and suffix are enabled Any data that does not match your data format requirements generates an error beep if Non Match Error Beep...

Страница 138: ...Enable Data Formatter Not Required Keep Prefix Suffix Enable Data Formatter Not Required Drop Prefix Suffix Non Match Error Beep If Non Match Error Beep is turned ON the scanner generates an error bee...

Страница 139: ...n below Multiple Data Formats On The scanner toggles from Format_0 through Format_3 until scanned data matches the requirements of one data format If no match is found the scanner generates an error b...

Страница 140: ...Formats feature is turned off For example you may have set your scanner to use the data format you saved as Format_3 You can switch to Format_1 for a single trigger pull by scanning the Single Scan Fo...

Страница 141: ...scan the Clear One barcode the 2 barcode and the Save barcode Delete all data formats Scan the Clear All barcode Clear All Clear One Query Data Formats You may scan the following barcode to get the i...

Страница 142: ...age starting from current cursor position followed by an insert character F2 Send a number of characters Syntax F2nnxx nn The numeric value 00 99 for the number of characters xx The insert character s...

Страница 143: ...return Command string F3440D F3 is the Send all characters up to a particular character command 44 is the hex value for a D 0D is the hex value for a CR The data is output as 1234567890ABC CR E9 Send...

Страница 144: ...nd to ignore F4 is the Insert a character multiple times command 09 is the hex value for a horizontal tab 02 is the number of times the tab character is sent The data is output as 1234567890AB tab tab...

Страница 145: ...ce 01 is the number of time the space character is sent B4 is the Insert barcode length command F4 is the Insert a character multiple times command 20 is the hex value for a space 01 is the number of...

Страница 146: ...cursor F1 is the Send all characters command 0D is the hex value for a CR The data is output as 4567890ABCDEFGHIJ CR F6 Move the cursor backward a number of characters Syntax F6nn nn The numeric valu...

Страница 147: ...Search for the letter D in barcodes and send all the data that follows including the D Using the barcode above Command string F844F10D F8 is the Search forward for a character command 44 is the hex v...

Страница 148: ...data that follows including FGH Using the barcode above Command string B00003464748F10D B0 is the Search forward for a string command 0003 is the string length 3 characters 46 is the hex value for F...

Страница 149: ...ll the data that follows E6 searches forward for the first character that is not zero then sends all the data after followed by a carriage return Using the barcode above Command string E630F10D E6 is...

Страница 150: ...rent cursor position as the cursor is advanced by other commands FB Example Remove spaces in barcode data This example shows a barcode that has spaces in the data You may want to remove the spaces bef...

Страница 151: ...e has characters that the host application does not want included you can use the E4 command to replace those characters with something else In this example you will replace the zeros in the barcode a...

Страница 152: ...nt cursor position search forward for the occurrence of SS1 string of length NN1 and replace the string with SS2 string of length NN2 in the output message until every SS1 string is replaced or the co...

Страница 153: ...23 s in barcode data If the barcode has a string of characters that the host application wants removed you can use the BA command to replace the string with NUL In this example you will remove the fir...

Страница 154: ...etween the 5th and 6th character Send the first 5 characters in a barcode wait for 1s then send the rest of the barcode data Command string F20500EF0200E900 F2 is the Send a number of characters comma...

Страница 155: ...ote that there is no space between a command and its terminator semicolon 3 Use the barcode generator software to generate a 2D batch barcode Example Create a batch barcode for Illumination Always On...

Страница 156: ...ch as the Maximum Minimum Length Decode Session Timeout Timeout between Decodes Same Barcode and Sensitivity Example Set the Decode Session Timeout to 3000ms 0313000 3000 Set the Sensitivity to level...

Страница 157: ...barcodes can be produced in the format of PDF417 QR Code or Data Matrix Example Create a batch barcode for llumination Always On Sense Mode Decode Session Timeout 2s 1 Input the following commands 020...

Страница 158: ...Enter Setup Exit Setup 146 Use Batch Barcode To put a batch barcode into use scan the following barcodes Use the example above Enter Setup Enable Batch Barcode Batch Barcode Exit Setup...

Страница 159: ...olution 1 If this problem happens to all barcodes and additional characters appear before after barcode data disable all prefix suffix 2 If this problem only happens to some barcodes and matches one o...

Страница 160: ...hat the scanner is properly powered up 2 Send to the scanner If the scanner returns a reply of then send programming commands to turn on illumination and aimer Problem Carriage Return Line Feed settin...

Страница 161: ...Type U S Convert Case No conversion Inter Keystroke Delay 10ms Beep on Unknown Character Do not beep Emulate ALT Keypad Disabled Function Key Mapping Disabled Emulate Numeric Keypad Disabled Code Page...

Страница 162: ...ssion Timeout 3 000ms Applicable to Manual mode Sense mode Continuous mode 100 3 600 000ms Timeout between Decodes 1000ms Applicable to Sense mode Continuous mode 0 65 535ms Timeout between Decodes Sa...

Страница 163: ...om Prefix Disabled None AIM ID Disabled Code ID Disabled Custom Suffix Disabled None Terminating Character Suffix Enabled 0x0D Carriage Return Image Control Image Flipping Do not flip Data Formatter D...

Страница 164: ...ximum Length 127 Minimum Length 1 EAN 8 EAN 8 Enabled Check Digit Transmit 2 Digit Add On Code Disabled 5 Digit Add On Code Disabled Add On Code Not required Extend to EAN 13 Disabled EAN 13 EAN 13 En...

Страница 165: ...Not Require Add On Code EAN 13 Beginning with 979 Add On Code Required Do Not Require Add On Code ISSN ISSN Disabled 2 Digit Add On Code Disabled 5 Digit Add On Code Disabled Add On Code Not required...

Страница 166: ...Disabled Check Digit Do not transmit Maximum Length 100 Minimum Length 6 Febraban Febraban Disabled Transmit Delay per Character Disabled 70ms Transmit Delay per 12 Characters Disabled 500ms ITF 6 ITF...

Страница 167: ...Enabled Check Digit Verification Disabled Check Digit Do not transmit Start Stop Character Do not transmit Code 39 Full ASCII Enabled Code 32 Disabled Code 32 Prefix Disabled Code 32 Check Digit Do no...

Страница 168: ...nabled Check Digit Verification One check digit MOD11 Check Digit Do not transmit Maximum Length 127 Minimum Length 2 Plessey Plessey Enabled Check Digit Verification Enabled Check Digit Do not transm...

Страница 169: ...9 Minimum Length 1 QR Twin Code Read single QR only Character Encoding Default Character Encoding Data Matrix Data Matrix Enabled Rectangular Barcode Enabled Mirror Image Decode Maximum Length 3116 Mi...

Страница 170: ...igit after verification I3 Do not transmit check digit after verification ITF 6 I1 Transmit check digit I3 Do not transmit check digit ITF 14 I1 Transmit check digit I3 Do not transmit check digit Ind...

Страница 171: ...ECC140 d1 ECC200 d2 ECC200 FNC1 is the 1st or 5th character after the start character d3 ECC200 FNC1 is the 2nd or 6th character after the start character d4 ECC200 ECI included d5 ECC200 FNC1 is the...

Страница 172: ...EAN 8 d EAN 13 d ISSN n ISBN B UPC E c UPC A c Interleaved 2 of 5 Febraban e ITF 6 e ITF 14 e Matrix 2 of 5 v Industrial 2 of 5 D Standard 2 of 5 s Code 39 Code 32 b Codabar a Code 93 i Code 11 H Ples...

Страница 173: ...eed 0b 11 VT Vertical Tab 0c 12 FF Form Feed 0d 13 CR Carriage Return 0e 14 SO Shift Out 0f 15 SI Shift In 10 16 DLE Data Link Escape 11 17 DC1 XON Device Control 1 12 18 DC2 Device Control 2 13 19 DC...

Страница 174: ...llar Sign 25 37 Percent 26 38 Ampersand 27 39 Single Quote 28 40 Left Opening Parenthesis 29 41 Right Closing Parenthesis 2a 42 Asterisk 2b 43 Plus 2c 44 Comma 2d 45 Minus Dash 2e 46 Dot 2f 47 Forward...

Страница 175: ...5 A 42 66 B 43 67 C 44 68 D 45 69 E 46 70 F 47 71 G 48 72 H 49 73 I 4a 74 J 4b 75 K 4c 76 L 4d 77 M 4e 78 N 4f 79 O 50 80 P 51 81 Q 52 82 R 53 83 S 54 84 T 55 85 U 56 86 V 57 87 W 58 88 X 59 89 Y 5a 9...

Страница 176: ...0 d 65 101 e 66 102 f 67 103 g 68 104 h 69 105 i 6a 106 j 6b 107 k 6c 108 l 6d 109 m 6e 110 n 6f 111 o 70 112 p 71 113 q 72 114 r 73 115 s 74 116 t 75 117 u 76 118 v 77 119 w 78 120 x 79 121 y 7a 122...

Страница 177: ...Idle to Sleep Example Set the time period from idle to sleep to 500ms 1 Scan the Enter Setup barcode 2 Scan the Time Period from Idle to Sleep barcode See the Auto Sleep section in Chapter 3 3 Scan th...

Страница 178: ...e threshold value of illumination change to 4 1 Scan the Enter Setup barcode 2 Scan the Threshold Value of Illumination Change barcode See the Sensitivity section in Chapter 3 3 Scan the numeric barco...

Страница 179: ...ng Area barcode 10 Scan the numeric barcodes 2 and 0 11 Scan the Save barcode 12 Scan the Right of Decoding Area barcode 13 Scan the numeric barcodes 8 and 0 14 Scan the Save barcode 15 Scan the Exit...

Страница 180: ...ASCII Table p 70 2 Scan the Enter Setup barcode 3 Scan the Modify PDF417 Code ID barcode See the Modify Code ID section in Chapter 6 4 Scan the numeric barcodes 7 and 0 5 Scan the Save barcode 6 Scan...

Страница 181: ...es with either the minimum or maximum length If you only want to read barcodes with a specific length set both minimum and maximum lengths to be that desired length Example Set the scanner to decode C...

Страница 182: ...ing barcode according to the symbology your application needs from the Character Encoding section in Chapter 8 6 Scan the Mode 3 barcode from the Emulate ALT Keypad section in Chapter 2 7 Scan the Exi...

Страница 183: ...Scan the Exit Setup barcode If you still need to program other parameter feature skip this step r Program the Custom Transmit Delay per 12 Characters for Febraban Example Set the transmit delay per 12...

Страница 184: ...172 Appendix 6 Digit Barcodes 0 9 0 5 1 6 2 7 3 8 4 9...

Страница 185: ...173 A F A B C D E F...

Страница 186: ...st Digit barcode and then the correct digit or scan the Delete All Digits barcode and then the digits you want For instance after reading the Maximum Length barcode and numeric barcodes 1 2 and 3 you...

Страница 187: ...VT Vertical Tab 0B Vertical Tab Ctrl K FF Form Feed 0C Delete Ctrl L CR Carriage Return 0D Enter Ctrl M SO Shift Out 0E Insert Ctrl N SI Shift In 0F Esc Ctrl O DLE Data Link Escape 10 F11 Ctrl P DC1...

Страница 188: ...B 1C 1D 1E 1F United States Ctrl Ctrl Ctrl Ctrl 6 Ctrl Belgium Ctrl Ctrl Ctrl Ctrl 6 Ctrl Scandinavia Ctrl 8 Ctrl Ctrl 9 Ctrl 6 Ctrl France Ctrl Ctrl 8 Ctrl Ctrl 6 Ctrl Germany Ctrl Ctrl Ctrl 6 Ctrl I...

Страница 189: ...177 Appendix 9 Code Pages List Numeric Barcode Needed Code Page 0 Windows 1252 Latin I 1 Windows 1251 Cyrillic...

Страница 190: ...06 UPC A 007 Interleaved 2 of 5 Febraban 008 ITF 14 009 ITF 6 010 Matrix 2 of 5 011 Code 39 Code 32 013 Codabar 015 Code 93 017 AIM 128 020 ISSN 023 ISBN 024 Industrial 25 025 Standard 25 026 Plessey...

Страница 191: ...Fremont Blvd Fremont CA 94538 USA Tel 510 490 3888 Fax 510 490 3887 Email info newlandna com Web www newlandamerica com Newland Latin America Tel 1 239 598 0068 Fax 1 239 280 1238 Email info newlandla...

Отзывы: