Enter Setup
** Exit Setup
20
The value of the
StoreType
field in a query command can be either
“
@
” (HEX:
40
) or “#” (HEX:
23
).
A query command with the
SubTag
field omitted means to query all the settings concerning a tag. For example, to query all
the current settings about Code 11, you should enter
7E 01 30 30 30 30 40 43 31 31 2A 3B
03
(i.e.
~<SOH>0000@C11*;<ETX>).
Responses
Different from command sequence, the prefix of a response
consists of the six characters of “<STX><SOH>0000” (HEX:
02 01 30 30 30 30
).
The scanner responds to serial commands with one of the following three responses:
<ACK>
(HEX:
06
) Indicates a good command which has been processed.
<NAK>
(HEX:
15
) Indicates a good configuration command with its
Data
field entry out of the allowable range for this
Tag and SubTag combination (e.g. an entry for an inter-keystroke delay of 100 when the field will
only allow 2 digits), or an invalid query command.
<ENQ>
(HEX:
05
) Indicates an invalid Tag or SubTag command.
When responding, the scanner echoes back the command sequence with the status character above inserted directly
before each of the punctuation marks (the comma or semicolon) in the command.
Examples
Example 1: Enable Code 11, set the minimum and maximum lengths to 12 and 22 respectively.
Enter:
7E 01 30 30 30 30 40 43 31 31 45 4E 41 31 2C 4D 49 4E 31 32 2C 4D 41 58 32 32 3B
03
(~<SOH>0000@C11ENA1,MIN12,MAX22;<ETX>)
Response:
02 01 30 30 30 30 40 43 31 31 45 4E 41 31 06 2C 4D 49 4E 31 32 06 2C 4D 41 58 32 32 06 3B
03
(<STX><SOH>0000@C11ENA1<ACK>,MIN12<ACK>,MAX22<ACK>;<ETX>)
Example 2: Query the current minimum and maximum lengths of Code 11.
Enter:
7E 01 30 30 30 30 40 43 31 31 4D 49 4E 2A 2C 4D 41 58 2A 3B
03
(~<SOH>0000@C11MIN*,MAX*;<ETX>)
Response:
02 01 30 30 30 30 40 43 31 31 4D 49 4E 31 32 06 2C 4D 41 58 32 32 06 3B
03
(<STX><SOH>0000@C11MIN12<ACK>,MAX22<ACK>;<ETX>)
Содержание NLS-HR15
Страница 1: ...NLS HR15 Hand held Barcode Scanner User Guide...
Страница 3: ...Revision History Version Description Date V1 0 0 Initial release December 4 2016...
Страница 21: ...5 Dimensions of the Scanner unit mm...
Страница 23: ...7 Dimensions of the Cradle unit mm...
Страница 83: ...Enter Setup 67 Exit Setup Norway Poland Portugal Romania Russia Slovakia Spain Sweden...
Страница 84: ...Enter Setup Exit Setup 68 Switzerland German Turkey_F Turkey_Q UK Japan...
Страница 97: ...Enter Setup 81 Exit Setup 8ms 9ms 10ms...
Страница 134: ...Enter Setup Exit Setup 118 40ms 45ms 50ms 55ms 60ms 65ms 70ms 75ms...
Страница 136: ...Enter Setup Exit Setup 120 500ms 600ms 700ms 800ms 900ms...
Страница 167: ...Enter Setup 151 Exit Setup Set ISBN Format ISBN 10 ISBN 13...
Страница 193: ...Enter Setup 177 Exit Setup PDF417 ECI Output Disable PDF417 ECI Output Enable PDF417 ECI Output...
Страница 200: ...Enter Setup Exit Setup 184 QR ECI Output Disable QR ECI Output Enable QR ECI Output...
Страница 206: ...Enter Setup Exit Setup 190 Set the Number of Barcodes 1 2 3 4 5 6 7 8...
Страница 266: ...Enter Setup Exit Setup 250 Modify Micro PDF417 Code ID Modify Micro QR Code ID Modify Code One Code ID...
Страница 270: ...Enter Setup Exit Setup 254 Disable Data Packing Enable Data Packing Format 1 Enable Data Packing Format 2...
Страница 276: ...Appendix Digit Barcodes 0 9 0 1 2 3 4 5...
Страница 277: ...6 7 8 9...
Страница 278: ...A F A B C D E F...
Страница 299: ...Unicode Key Maps 104 Key U S Style Keyboard 105 Key European Style Keyboard...