Enter Setup
】
**
【
Exit Setup
】
22
Continuous Mode
If the Continuous mode is enabled, the scanner automatically activates one decode session after another.
【
Continuous Mode
】
Decode Session Timeout
This parameter sets the maximum time decode session continues during a scan attempt. If the timeout expires or the
barcode decodes, the decode session stops. It is programmable in 1ms increments from 0ms to 3,600,000ms. The default
setting is 3,000ms.
【
Decode Session Timeout
】
Example: Set the decode session timeout to 1500ms
1.
Scan the
Enter Setup
barcode.
2.
Scan the
Decode Session Timeout
barcode.
3.
Scan the numeric barcodes “1”, “5”, “0” and “0”.
4.
Scan the
Save
barcode.
5.
Scan the
Exit Setup
barcode.