nlscan.com
Page 79
Symbols
Tools
Code Programming ON
Code Programming OFF
Select Message Length
It is used to program the valid reading length of COOP25. The scanner will
send an error beep, if the decoded data length does not match the valid length.
COOP25 Message Length is de
fi
ned by
“
Min. Message Length
”
and
“
Max. Message Length
”
.
COOP25
(
Japanese Matrix 2 of 5
)
1D bar code Message Length should not exceed 255 bytes. If Max Message Length is less
than Min Message Length, it means the scanner will only support barcodes of the two
lengths. If Max Message Length is equal to Min Message Length, the scanner will only sup-
port barcodes of the length.
To set Min Message Length of COOP25 to 8 bytes and the Max Message Length to 12
bytes. Read these programming code:
1.
“
Code Programming ON
”
2.
“
Select Min Message Length
”
3. Digit Code
“
8
”
, see Digit Code (Appendix Pxxx)
4.
“
Save Programming
”
, see Digit Code (Appendix Pxxx)
5.
“
Select Max Message Length
”
6. Digit Code
“
1
”
7. Digit Code
“
2
”
8.
“
Save Programming
”
9.
“
Code Programming OFF
”
Min Message Length
【
Pro CMD
:
99911706
】
Max Message Length
【
Pro CMD
:
99911707
】