165
g. Program the Central Area
Example: Set the percentage of central area to 20%
1. Scan the
Enter Setup
barcode.
2. Scan the
Specify Central Area
barcode.
3. Scan the numeric barcodes “2” and “0”.
4. Scan the
Save
barcode.
5. Scan the
Exit Setup
barcode. (If you still need to program other parameter/feature, skip this step.)
h. Program the Custom Prefix/Suffix
Example: Set the custom prefix to “CODE”
1. Check the hex values of “CODE” in the ASCII Table. (“CODE”: 43, 4F, 44, 45)
2. Scan the
Enter Setup
barcode.
3. Scan the
Set Custom Prefix
barcode. (See the
“Set Custom Prefix”
section in Chapter 6)
4. Scan the numeric barcodes “4”, “3”, “4”, “F”, “4”, “4”, “4” and “5”.
5. Scan the
Save
barcode.
6. Scan the
Exit Setup
barcode. (If you still need to program other parameter/feature, skip this step.)
i. Program the Terminating Character Suffix
Example: Set the terminating character suffix to 0x0D
1. Scan the
Enter Setup
barcode.
2. Scan the
Set Terminating Character Suffix
barcode. (See the
“Set Terminating Character Suffix”
section in Chapter 6)
3. Scan the numeric barcodes “0” and “D”.
4. Scan the
Save
barcode.
5. Scan the
Exit Setup
barcode. (If you still need to program other parameter/feature, skip this step.)
Содержание HR3290 Marlin
Страница 1: ...HR3290 Marlin Corded 2D Barcode Scanner User Guide...
Страница 21: ...Enter Setup 9 Exit Setup Dimensions unit mm Left View Front View...
Страница 22: ...Enter Setup Exit Setup 10 Top View...
Страница 59: ...Enter Setup 47 Exit Setup Beep Type Type 1 Type 3 Type 2 Beep Volume Loud Low Medium...
Страница 182: ...170 Appendix 6 Digit Barcodes 0 9 0 5 1 6 2 7 3 8 4 9...
Страница 183: ...171 A F A B C D E F...
Страница 187: ...175 Appendix 9 Code Pages List Numeric Barcode Needed Code Page 0 Windows 1252 Latin I 1 Windows 1251 Cyrillic...