background image

Nightwitness  is a sophisticated precise optical instrument equipped with electronics.

Therefore, it should be handled with due care.

Try to avoid strong heat, direct sunlight, impacts, dust, moisture and sudden changes of

temperatures. Keep it in mind that, although being very durable, Nightwitness contains fragile

                  components.

Do not touch the optical surfaces with fingers. Doing so may damage the antireflection  coating.

Cleaning of optical surfaces should only be performed with professional camera lens cleaning

supplies.

Use only a soft clean cloth to clean the exterior of the device.

Do not take the cover off the lens if not necessary.

Keep away from heating appliances and central heating.

Make sure to switch off the unit and remove the battery during periods of non-operation

  and when storing the device for long period of time.

Do not apply unnecessary pressure to the lens assembly, agile elements & thread connections.

Due to considerable optical magnification of the eyepiece some small structures inside the tube

coating in the form of dark and/or white points may be seen in the field of view which does not
affect the serviceability of the device.

PRECAUTIONS

7

Warning !

Warning !

Warning !

Warning !

Warning !

Image Intensifier possible defects table.

Clarity of Image Intensifier tube is check against the table below:

Í î ì åð

 çî í û

Ðàçì åð çî í ,

ì ì

Í àèáî ëüøèé  äèàì åòð òî ÷åê, ì ì

Äî ï óñòèì àÿ ñóì ì àðí àÿ

ï ëî ù àäü äåô åêòî â,

,

  ì ì  

2

í å

ó÷èòû âàåì û õ

äî ï óñòèì û õ

ï î  ðàçì åðó, ì ì

ï î  êî ëè÷åñòâó

1

2
3

0...9,0

9,0...14,5

14,4...18,0

0,06
0,08

0,1

0,15
0,25
0,35

1

2
2

0,12
0,27
0,45

TECHNICAL SPECIFICATIONS  (CONT)

6

ZONE

NUMBER

CIRCULAR ZONE

DIMENTIONS, MM

FIELD OF VIEW CLEANNESS:

NEGLECTED

ADMITTED

DIAMETER, MM

QUALITY

ADMITTED TOTAL

AREA OF DEFECTS, MM

2

Содержание NIGHT VISION MONOCULAR

Страница 1: ...tracture 8 Functions and Indicators 12 Operation Instructions 14 Warranty 22 Customer Support 24 Acceptance certificate 25 TABLE OF CONTENTS Operation Manual NIGHTWITNESS NIGHT VISION MONOCULAR In USA 2331 Superior Ave Cleveland OH 44114 In Canada 105 Sparks Ave Toronto ON M2H 2S5 ...

Страница 2: ... long trouble free operation Replaceable desiccant cartridge im proves its reliability substantially Nightwitness is distinguished by its handy modular design along with an intelligent control system On client request it can be equipped with wide variety of accessories including interchangeable lenses adapters for coupling CCTV 35 mm digital photo and video cameras Nightwitness is provided with a ...

Страница 3: ...torage temperature 30 Ñ 50 Ñ Humidity 98 SPECIFICATIONS TECHNICAL SPECIFICATIONS con t 5 SPECIFICATIONS Magnification 5 0 3 õ 1 25 0 1 õ Field of View 5 õ 10 5 1 25 õ 40 Focusing Range 3 ì to Infinity IMAGEINTENSIFIERTUBE Type 18 ìì Gen II Extra Definition 18 ìì Gen III GaAs Photocathode sensitivity integral 350 600 uA lm 500 1600 uA lm spectral at λ 850 nm 18 40 mA W 70 120 mA W Resolution 36 64 ...

Страница 4: ... and when storing the device for long period of time Do not apply unnecessary pressure to the lens assembly agile elements thread connections Due to considerable optical magnification of the eyepiece some small structures inside the tube coating in the form of dark and or white points may be seen in the field of view which does not affect the serviceability of the device PRECAUTIONS 7 Warning Warn...

Страница 5: ...ds power supply of the device will be switched off When the luminance goes down below that level the Image Intensifier power supply recovers automatically So the operator has plenty of time to protect the device from bright light sources and at the same time not to lose the sight of an object to be controlled UNIT STRUCTURE con t 9 Operation switches as well as the battery compartment and a place ...

Страница 6: ...The case is made from nylon with soft padded inserts designed to absorb the shock of impact as well additional packets for other tools The case also has adjustable shoulder strap UNIT STRUCTURE con t 11 POWERSOURCE Power source for NVD is provided by one Ni MH power cell voltage 1 2V not less 2300 mAh type ÀÀ or one Alkaline battery voltage 1 5V type ÀÀ This is enough for continued operation for u...

Страница 7: ... Low Battery Indicator red Power ON indicator green Strap holder Power ON OFF switch IR fixed security switch Battery House cover Tripod Thread 1 4 Focusing Ring Objective lens I R illuminator FUNCTIONS AND INDICATORS 12 Dioptrict adjustment ring Eye piece Desiccant Main body of Nightwiness ...

Страница 8: ...ned OFF by moving the switch to OFF position on the unit Close the objective cover OPERATION INSTRUCTIONS con t 15 Precautions Never disassemble the unit by yourself There are no wires or modules that requires user to clean or modify Operation procedures Twist off the battery house cap Insert one battery type ÀÀ 1 5V make sure that polarity is correct Screw the battery cap back on Take the unit in...

Страница 9: ...pply is between 0 9 1 0 V in this case the Green unit ON indicator is off If the voltage is very low less than 0 9V all indicators of NVD will automatically turn off Turn OFF the unit and replace the battery INDICATOR HIGH LIGHT CUT OFF High light indicator is blue color and is located in the ocular field of view this indicator light will blink if the unit is exposed to bright light source that ca...

Страница 10: ...a on the object of your choice Establish maximum resolution of the image by focusing the objective ring located on the objective lens of the unit At this stage you can take photos or make a video at night OPERATION INSTRUCTIONS con t 19 Using the unit with external power supply of car adapter Remove battery house cover Remove the battery ÀÀ and insert a external power adapt er optional Lock the ca...

Страница 11: ...he unit performs reliably in harsh weather conditions and high moistures it is expected that user will do due diligence and pay more close attention to operation instructions in order to keep unit in good working order and prevent early demise of the unit Low temperature operation Unit functions properly at temperatures below 20 C In low temperatures the objective focus ing ring as well as dioptri...

Страница 12: ...epair or at its option replace with the same or comparable model the product or part thereof which on inspection by Newcon is found to be defective in materials or workmanship What This Warranty Does Not Cover NEWCON is not responsible for warranty service should the product fail to be properly maintained or fail to function properly as a result of misuse abuse improper installation neglect damage...

Страница 13: ...onsales newcon optik com Web www newcon optik com The defective products should be shipped to From USA only 2331 Superior Ave Cleveland OH 44114 From all other countries 105 Sparks Ave Toronto ON M2H 2S5 CANADA 24 CUSTOMER SUPPORT Image Intensifier Tube Image Intensifier Tube Serial Number ____________ Date of production __________ Quality Inspector signature ____________ The unit with the serial ...

Отзывы: