background image

 

3. DELIVERY SET  

 

Standard delivery set 

LRM 1500M / 1800S is supplied in the following assembly: 

 Qty 
LRM  

9V Alkaline battery 

Soft carrying case 

Neck strap 

Operation manual 

Warranty card 

Содержание LRM 1500M

Страница 1: ...Operation Manual LRM 1500M LRM 1800S LASER RANGEFINDER MONOCULAR 105 Sparks Ave Toronto ON M2H 2S5 Canada...

Страница 2: ......

Страница 3: ...ransport the unit without the case NEVER disassemble the unit This may be hazardous for you due to high voltage currents in the system ALWAYS keep the unit out of the reach of children ALWAYS remove t...

Страница 4: ...ht light from focussing through the eyepiece Never aim the unit at highly reflective objects like mirrors and retroreflective surfaces which are in close proximity to the laser rangefinder This can le...

Страница 5: ...T 6 3 1 Standard delivery set 6 4 SPECIFICATIONS 7 5 OPERATION INSTRUCTIONS 9 5 1 Changing battery 10 5 2 Measuring procedure 11 5 3 Maximum distance 11 5 4 Mode selection 12 5 5 Additional display in...

Страница 6: ...measurement The unit complies with CFR 21 Part 1040 10 An outstanding fully multi coated optics coupled with an original circuitry design creates a system that outperforms any other product in its cl...

Страница 7: ...r obstacles Three channel optical solution optical laser and receiver provides high accuracy Two reticle shapes or Target quality display indicator assures that results are reliable On board memory ke...

Страница 8: ...4 2 3 4 5 6 7 1 8 2 DEVICE APPEARANCE Fig 1 Front view 1 Eyepiece 2 Objective lens 3 Laser emitter lens 4 Receiver lens 5 M Mode button 6 A Action button 7 Body of the device 8 Rubber grip...

Страница 9: ...5 Fig 2 Rear view 1 Eyepiece 9 Battery compartment cover 10 Tripod socket 11 Identification imprint 12 Classification imprint shown below 9 11 1 12 10...

Страница 10: ...6 3 DELIVERY SET Standard delivery set LRM 1500M 1800S is supplied in the following assembly Qty LRM 1 9V Alkaline battery 1 Soft carrying case 1 Neck strap 1 Operation manual 1 Warranty card 1...

Страница 11: ...view Type of coating 7x 25 mm 3 6 mm 8 Fully multi coated optics Range Finder Laser Measuring range LRM 1500M Measuring range LRM 1800S Accuracy Meters Yards display Last 10 readings recall Reticle T...

Страница 12: ...h Accuracy 2 km h Power Battery 9V Low Battery indicator Yes Environmental Operational temperature range Storage temperature range 25 50o C 13 122o F 45 65o C 49 149o F Mechanics Tripod thread Weight...

Страница 13: ...dicator 2 Reticle either or 3 Units of measurement 4 Measurement result 5 Target quality indicator 6 Laser active indicator 7 Setup mode indicator 8 Ready mode indicator 4 6 2 1 3 8 7 Fig 3 Liquid Cry...

Страница 14: ...ent easily it means that polarity was reversed To take a battery out Slide the battery compartment cover down 9 Fig 2 Shake the rangefinder gently towards the open end of the battery compartment Pull...

Страница 15: ...harp through the optical system Pressing A button 6 Fig 1 in Ready to Measure mode initiates measurement The result of measurement is displayed in a form that depends on the measurement parameters see...

Страница 16: ...ll reduce performance as well as IR sun radiation may interfere with reflected laser impulses While the unit will measure through many glass types measuring through glass may reduce accuracy Natural h...

Страница 17: ...appear Pressing M button moves the unit along the list of measurement set numbers and measurement results rEc 1 rEc 2 rEc 0 If distance was not measured it will not appear in the list Measurement sets...

Страница 18: ...the influence of obstacles like rain flakes trees wires and so on Qualitative result of the statistical processing is presented on the Display as a message TARGET REFLECTION 5 Fig 3 There are three s...

Страница 19: ...higher than 50o C 122o F Prevent unit from direct sunlight Do not touch optical surfaces Doing so may damage the anti reflection coating Clean optical surfaces only with professional camera lens clea...

Страница 20: ...inherited from the manufacturing process These flaws are strictly regulated by number area and location and do not degrade the product s measurement capabilities Range measurement cannot be obtained M...

Страница 21: ...model the product or part thereof which on inspection by Newcon is found to be defective in materials or workmanship What This Warranty Does Not Cover NEWCON is not responsible for warranty service sh...

Страница 22: ...Standard Time At no time should equipment be sent back to Newcon without following the instructions of our technical support department NEWCON OPTIK accepts no responsibility for unauthorized returns...

Страница 23: ...19 10 QUALITY CERTIFICATE LRM 1500M LRM 1800S The unit indicated above has passed the quality inspection Production date Serial number Quality Inspector Purchase date...

Страница 24: ...NEWCON OPTIK Printed in Canada R1 TS 02 12...

Отзывы: