Table 10.2
Operations
Procedure as per
Materials, tools and accessories
1. Servicing within
check inspection
scope
2. Cleaning range
finder to remove
dust, dirt and
moisture
3. Touching up pain-
ted exterior of
range finder (when
so required)
4. Drying and repair
of straps (when so
required)
5. Replacing silica
gel (when so re-
quired)
6. Replacing defective
components with
spares to be taken
from individual
SPTA set
7. Tightening sleeves
on knob end faces
As in Table 11.1
Para. 11.6.3
Para. 12.3
Table 10.1,
para.10
As in Table 11.1
Cloth
Brush, painting Enamel, grade
GF-1426, GOST 6745-79
Silica gel, indicating GOST
8984-75, metal vessel
Individual SPTA set
10.5. In-service Maintenance.
10.5.1. During in-service maintenance, the range finger is
checked for serviceable condition in accordance with Steps 1 through
10 of Table 9.1.
10.5.2.The unit is not to be dismantled during in-service
maintenance.
10.5.3. For the servicing scope, refer to Table 10.3.
Table 10.3.
Operations
Procedure as per
Materials, tools and accessories
1. Servicing within
daily scope
2. Cleaning
contacts
of charging
device, protection
device, wires and
battery section
3. Repair
of
packing
case (when so
required)
As in
Table
10.2.
Para 10.6.1.
As in
Table 10.2.
Absorbent optical cotton,
alcohol
Equipment, appliances and
tools available in repair shop
10.5.4. During in-service maintenance, the cycle life of the
range finder may not be spent by more than10 measurements.
10.6. Maintenance Servicing Procedure.