Table 10.2 

 

Operations 

Procedure as per 

Materials, tools and accessories 

 
1. Servicing  within 
    check inspection     
    scope      
2. Cleaning  range  
    finder to remove 
    dust,  dirt  and 
    moisture 
3. Touching up pain- 
    ted  exterior   of 
    range finder (when 
    so required) 
4. Drying and repair 
    of straps (when so 
    required) 
5. Replacing silica 
    gel (when so re- 
    quired) 
6. Replacing defective 
    components with 
    spares to be taken 
    from individual 
     SPTA set 
7. Tightening sleeves 
    on knob end faces  
 
 

 
As in Table 11.1 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Para. 11.6.3 
 
 
Para. 12.3 
 
 
 
 
 
Table 10.1,  
para.10 

 
As in Table 11.1 
 
 
Cloth 
 
 
 
 
Brush, painting Enamel, grade 
GF-1426, GOST 6745-79 
 
 
 
 
 
 
Silica gel, indicating GOST 
8984-75, metal vessel 
 
Individual SPTA set 

 

 

 

 

10.5. In-service Maintenance. 

 

10.5.1. During in-service maintenance, the range finger is 

checked for serviceable condition in accordance with Steps 1 through 
10 of Table 9.1. 
 

 

 

10.5.2.The unit is not to  be dismantled during in-service 

maintenance.  
 

10.5.3. For the servicing scope, refer to Table 10.3. 

 

         Table 10.3. 

 

Operations 

Procedure as per 

Materials, tools and accessories 

1. Servicing within 

daily scope 

 

2. Cleaning 

contacts 

of charging 

 

device, protection 
device, wires and 
battery section 

 
3. Repair 

of 

packing 

case (when so 
required) 

As in 

Table 

10.2. 
 
Para 10.6.1.

 

As in 

Table 10.2. 

 
 
Absorbent optical cotton, 
alcohol 
 
 
 
 
Equipment, appliances and 
tools available in repair shop 

 

 
 

10.5.4. During in-service maintenance, the cycle life of the 

range finder may not be spent by more than10 measurements. 
 

10.6. Maintenance Servicing Procedure. 

Содержание LRB 20

Страница 1: ...d NEVER subject the unit to impact while operating or being transported NEVER aim the unit at the sun NEVER measure ranges to mirror reflecting surfaces NEVER touch optical surfaces with fingers NEVER...

Страница 2: ...NGE FINDER BINOCULARS LRB 20 000 is an advanced Laser Range Finder system that provides instant distance measurements consistently and accurately The stereoscopic device provides convenient observatio...

Страница 3: ...om temperature for at least two hours before unpacking and then mop up the condensed moisture while operating the range finder at temperatures above 35 C and exposing to direct sunrays attach cover AE...

Страница 4: ...e between 40 and 50 C relative air humidity of up to 98 as taken at 35 C air pressure of 61 kPa 460 mm Hg minimum and in the sea mist conditions 2 5 Power to the range finder is supplied from recharge...

Страница 5: ...Table 4 1 Description Designation Q ty Serial No Remarks 1 Range finder 2 Tripod optional 3 Angular Mount optional 4 Rechargeable battery 5 Fuse link VP1 1 1 0 A 250 V 6 Sealing ring 7 Framed lens 8...

Страница 6: ...beam The range finder works on the principle of measuring the light pulse round trip time The measurement result is displayed in metres on digital range indicator and also stored in the computer in bi...

Страница 7: ...ount Fig 4 is intended for mounting range finder on a tripod to lay the range finder on the target and to read the azimuth and elevation The Angular Mount AI is essentially body 15 which incloses the...

Страница 8: ...tical components grinded and polished surfaces which are nearer to range finder than 1700 m direct radiation to diffuse reflecting surfaces walls curtains papers which are nearer to range finder than...

Страница 9: ...isplayed in all the digit positions and the decimal point in the third position 7 4 To use AI and tripod for observation proceed as follows Arrange the tripod on selected site Extend the telescoping l...

Страница 10: ...small size things flash light knife screwdriver etc are 20 cm away from the instrument 7 6 To check the range finder for proper operation when using the AI and the tripod check the AI zero elevation r...

Страница 11: ...hen ranging fixed targets proceed as follows set the ON OFF selector switch to the ON position lay the range finder on the target so that the latter or its visible portion is observed in the central g...

Страница 12: ...f the reticle is 0 05 mils large division value is 0 10 mils 8 6 To measure vertical and elevation angles proceed as follows align the horizontal mark of the range finder Binocular reticle with the up...

Страница 13: ...drawn line Mark the obtained OP location point on the circular scale adjust the circular to read the directional angle as determined for the target from observation post pass a vertical line from bott...

Страница 14: ...range finder Binocular reticle is illuminated Measurement results are within 5 m of predetermined range or on another ER O error determined for vertical angle scale is to be reckoned in while measurin...

Страница 15: ...y In service maintenance is performed every six months and before placing the range finder in short term storage 10 3 Check Inspection 10 3 1 During the check inspection is ascertained the serviceable...

Страница 16: ...dividual SPTA set 10 5 In service Maintenance 10 5 1 During in service maintenance the range finger is checked for serviceable condition in accordance with Steps 1 through 10 of Table 9 1 10 5 2 The u...

Страница 17: ...in a closed room Under the field conditions replace the silica gel when the weather is dry and calm Never keep the case with fresh silica gel open for more than 1 or 2 minutes To change the silica gel...

Страница 18: ...as directed under 12 3 2 11 3 To correct problems by using the individual SPTA set proceed as follows see Fig 6 11 3 1 To replace the fuse link 2 in the protection device unscrew the threaded cover f...

Страница 19: ...1 3 5 The individual SPTA set is stowed in packing case 4 Fig 7 The spare Rechargeable battery pencil eraser cloth and coordinate converter are stowed in the case 12 LONG TERM STORAGE To preserve the...

Страница 20: ...re so as to prevent impact 15 RECHARGEABLE BATTERY HANDLING 15 1 The rechargeable battery is supplied in discharged condition 15 2 While handling the battery be certain to avoid contact with any bare...

Страница 21: ...r Cycle 2 as directed in 15 3 3 then charge it up to the operating voltage as directed in 15 3 1 With the discharging time under 3 5 hours the battery is not to be used 15 3 4 The battery that has not...

Страница 22: ...brought to pin 8 of connector X2 in form of a positive pulse edge Table 16 1 Address Data X2 7 X2 6 X2 5 X2 1 X2 2 X2 3 X2 4 0 0 0 0 1 0 0 1 1 0 0 1 0 1 0 ones of meters 0000 or 0101 tens of meters f...

Страница 23: ...______ Long Term Storage period _____________________ Preserved by ___________________________ Accepted after Stamp here Long Term Storage by ___________________________ 19 PACKING CERTIFICATE Binocul...

Страница 24: ...ervice Postage insurance or shipping costs incurred in presenting your NEWCON product for warranty service are your responsibility Please include a check or money order made out to NEWCON OPTIK for th...

Страница 25: ...3 tripod Fig 1 Range finder viewed on the side of eyepiece 1 housing 2 MEASURE 1 and MEASURE L buttons 3 belt 4 panel 5 ILLUMINATION toggle switch lever 6 Binocular eyepiece 7 screw 8 indicator eyepie...

Страница 26: ...knob 2 lever 3 bracket 4 retainer 5 scale 6 framed lens 7 adjustment knob 8 compass 9 nut M8 10 framed lens 11 knob 12 support 13 level 10 14 azimuth circle 15 body Fig 4 Tripod mount 1 mounting head...

Страница 27: ...12 protection device 13 indicating silica gel 14 through 18 cable 19 membrane 20 21 cover 22 diaphragm 23 brush No 7 made from synthetic fibre Fig 6 Binoculars range finder unit LRB 20 000 in packing...

Отзывы: