6.  OPERATION INSTRUCTIONS 

WARNING! 

 

NEVER OPERATE YOUR NIGHT VISION DEVICE  IN 
DAYLIGHT AREAS WITHOUT THE LENS COVERS ON! 
NEVER DIRECT THE LENS IN THE DIRECTION OF BRIGHT 
LIGHT! 

 

6.1

 

Pre-starting procedures. 

 

Unpack the device. Open the  battery house cover (2), and install the 
battery. Observe the correct polarity indicated on the housing. Close 
the battery house cover. 
 

6.2

 

Daytime testing. 

 

Check the functioning of the device by switching it on (push and hold 
button 4) and looking through the eyepieces (5). 

(Make sure the lens 

caps are on while operating during the day). 

If power supply and 

the batteries are O.K., you will see greenish-lit screen. If the screen is 
not lit, check the batteries. Replace the battery if necessary. If 
everything works, now it is a great time to fill the warranty card. 

Note:

  The unit will remain on for up to several minutes after 

releasing the “On” button. This is normal. 

Direct the device on an object placed within 8-15m from the 

viewer. Turning the eyepieces (5) try to achieve the sharpest image on 
the screen of the image tube. Adjust the distance between the eyes by 
folding the binoculars until two images merge into one. If you wear 
glasses fold the eyepiece rubber guards (5) to obtain closer focus 
distance.

 

 
 

Warning!

 After transportation or keeping the device at 

temperature lower than -25

°

C (-13

°

F), the device must be warmed 

up to ambient temperature for at least 2 hours.

  

 
Precautions

  

 
BN 5 is a sophisticated precision optical instrument equipped with 
electronics. Therefore, it should be handled with due care. 

 

Keep your device away from direct sunlight, impacts, dust, 
moisture, and sudden changes of temperatures.  

 

Cleaning of optical surfaces is possible only with professional 
camera lens cleaning supplies. 

 

Do not touch optical surface with fingers. Doing so may 
damage the anti-reflection coating. 

 

To clean the exterior of the device, use only a soft clean cloth. 

 

Do not take the covers off the lenses if not necessary. 

 

Keep away from heating appliances and central heating. 

 

Make sure to switch off the unit during periods of non-
operation and when storing the device for long period of time. 

 

Do not apply superfluous efforts at work with lens assembly, 
agile elements and thread connections. 

Due to considerable optical magnification of the eyepiece some 
small structures inside the tube coating may be seen in the field of 
view in the form of dark and/or white points, which does not affect 
the serviceability of the device 
The resolving power (resolution) may change in the direction from 
the center towards the perimeter of the field of view. This is an 
inherent feature of the image tube type utilized in the device. We 
would recommend to place the scene of observation in the center 
of the field of view. 

 