Newco NB-LD Скачать руководство пользователя страница 4

Manual PN 119985 Rev 02-06 Firmware Rev 4 

 

OPERATION INSTRUCTIONS 

 

Coffee Preparation Procedures 

 
1) 

Place filter into brew basket. 

2) 

Put the proper amount of coffee into the filter. 

3) 

Slide the brew basket into holder. 

4) 

Place the appropriate empty decanter into position below the brew basket. For airpots first open lid and remove 
pump stem unless of a brew through design. For other dispensers remove the lid unless it is a brew through 
design. 

5) 

Press the appropriate brew start switch.  Note: a brew cycle may be initiated even if the heating light is on.  The 
brewer features an autoarm circuit which will flash the heating light indicating that the brewer is heating and will 
begin to brew immediately after the heating cycle is complete.  To over ride autoarm, hold in brew button until 
cycle starts (5 seconds). 

6) 

Do not remove decanter.  Brew cycle may be canceled by depressing any brew button or the cancel switch on 
the front control panel. 

7) 

Hot water will be delivered through the sprayhead. This distributes the hot water evenly over the coffee bed 
within the brew basket. The coffee brew will drain from the brew basket into the decanter below. 

8) 

The Brewing light should continue to flash until all the liquid has finished flowing from the brew basket. Do not 
remove decanter until the brewing process has stopped and all liquid has stopped flowing from the brewbasket. 

9) 

The resultant coffee brew should be crystal clear and have the desired properties attainable through excellent 
extraction. 

10) 

To clean brew basket simply remove from brew rails and dump filter into waste basket. The brewing process, as 

described above, can now be started again. 

 

Error Messages 

 
This brewer incorporates a number of self diagnostic test that are routinely run.  If a fault condition should occur the 
unit will display an error number as outlined below.  All errors may be reset by powering unit off and then back on.  
Errors E1 and E2 are auto-resttable and will clear themselves if the condition that caused them goes away.  You may 
still brew, but call for service.  E3 will disable heater but will allow brewing to take place. E4 and E-A must have power 
to unit cycled to clear them.  E5 will force brewer to use its default settings for brewing.  E7 and E8 will clear when a 
brew cycle is started.  E9 will disable input from dsplay board.  If error repeats, correct the cause of the error. 
 

Error 

Number 

Description 

Cause 

What to Check 

E1 Open 

Thermistor 

Resistance extremely high from 
upper or lower thermistor 

Check/replace thermistor. 

E2 Shorted 

Thermistor 

Resistance extremely low from upper 
or lower thermistor 

Check/replace thermistor. 

E3 Heater 

Run 

Error 

Water did not heat within timeout 
period 

Check element for short and proper 
resistance.  Replace if bad. 

E4 

Tank Fill Error 

Water did not reach probe in timeout 
period 

Check valve function and flow rate.  
Replace valve or increase flow rate.  Check 
probes for excess scale. 

E5 

Comm Error 

Serial communication error to/from 
non-volatile memory (EEPROM). 

Replace main board. 

E7 Open 

Motor 

Circuit 

Open motor circuit.  Pump 0 or 
pump 1.  

Check harness/motor continuity.  Replace 
if defective. 

E8 Bad 

(Open) 

Motor Driver 

Bad/open motor driver. Pump 0 or 
pump 1. 

Replace main board. 

E9 

SPI Comm Error 

Serial communication error to/from 
display board. 

Verify good connection in proper port.  Try 
new display board.  Try new main board. 

E-A Possible 

Leak 

Detected 

Water system may have a leak.  

Check all plumbing system components for 
possible leak.  Look for water on counter. 

Full 

Filter Full 

Water filter has reached capacity. 

Replace filter. 

 
 
 

Содержание NB-LD

Страница 1: ...PN 119985 Rev 02 06 1 20 1 Brewer Operation and Service Manual Model Height Width Depth US 120 V Canada 120 V 240 V NB LD 17 7 8 8 1 2 19 1 4 14 6A 11 7A 14 6A NB TD 24 3 16 8 1 2 19 1 4 14 6A 11 7A...

Страница 2: ...initiated as outlined below The following will outline the various steps as displayed by the programming screens The screens will loop continuously until exiting the mode Service Mode is entered by ho...

Страница 3: ...ct with the water Upper Lower or Both Exit End N A Use left or right button when displayed to exit this mode User Mode is entered by holding any of the buttons on the face of the machine while powerin...

Страница 4: ...rewer incorporates a number of self diagnostic test that are routinely run If a fault condition should occur the unit will display an error number as outlined below All errors may be reset by powering...

Страница 5: ...LON 3 16 ID 6 Alternate 119836 COPPER TUBE ASSEMBLY 1 7 202044 INSERT TUBING 3 16 1 8 110946 NUT 1 4 SELF ALIGN 1 9 110944 SLEEVE 1 4 SELF ALIGN 1 10 101720 CONNECT FM 3 8C x 1 8P TNPL 1 11 102836 GRO...

Страница 6: ...N 119985 Rev 02 06 Firmware Rev 4 6 LID ASSEMBLY 119972 CONTINUED 2 3 1 Item Part Description Qty 1 100409 GASKET BRASS 520ID TN PLT 2 2 151677 PROBE TEMP DUAL 7 312 THERM 1 3 202025 ELEMENT TANK 1750...

Страница 7: ...06 Firmware Rev 4 7 TANK 2 1 3 4 6 5 Item Part Description Qty 1 704221 GASKET 1 2 119971 TANK PUNCHED 1 3 111635 CLAMP HOSE 574 ID 2 4 152213 TUBING SIL 3 8 ID x 5 8 OD 5 102835 BULKHEAD FAUCET 2 6 7...

Страница 8: ...AY BOARD HARNESS 1 2 120025 SPACER 6 32 3 8 HEX x 7 16L 3 3 120046 SCREW 6 32 x 1 4 PPHMS POLY 3 4 110941 WASHER NYL 151 x 345 x 031 3 5 119970 BREW PLATE SPTWLD 1 6 152218 TUBING SIL 1 4 ID x 3 8 OD...

Страница 9: ...6 NUT 1 4 SELF ALIGN 1 4 202044 INSERT TUBING 3 16 1 5 101527 REPLACEMENT KIT KIP VALVE 1 6 105115 TRANSFORMER 1 7 100022 CORD POWER 1 8 101035 GROMMET STRN RELIEF 1 9 101898 CORD PLATE 1 10 110626 SW...

Страница 10: ...N CABLE WARRANTY Newco coffee brewers are warranted against defects in workmanship or materials under normal use for 90 days from the date of purchase Brewer parts are warranted against defect for 12...

Отзывы: