background image

   

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

LCD-1 By NEWCO Enterprises

 

 

Installation  

And  

Programming Guide 

Содержание LCD-1

Страница 1: ...LCD 1 By NEWCO Enterprises Installation And Programming Guide...

Страница 2: ...n ng g f fo or r u us se e a as s w wa at te er r s su up pp pl ly y t to o a al ll l o of f o ou ur r b br re ew wi in ng g e eq qu ui ip pm me en nt t Turn water Supply On Plug or wire brewer to the...

Страница 3: ...y screen Three dashed lines will appear on the display screen as shown in figure 1 Step 1 Enter a Programming Mode Press and hold the center switch labeled Enter After five seconds the display will ch...

Страница 4: ...amming option Either the word YES or the word NO will appear on the display screen Proceed to Step 3 Step 3 Enable Disable BIB Tracking This machine features the option to track the liquid output of t...

Страница 5: ...three things has occurred BIB Tracking has detected an empty BIB See step 4 A machine malfunction has been detected The machine has completed a sanitization cycle This feature offers the option to di...

Страница 6: ...ed for Hot Water Dispense The remaining 3 switches can be programmed to deliver different strength drinks or different sized drinks see Figure 9 Page 7 Program selection product To program a selector...

Страница 7: ...e display will change to identify the switch that you have chosen b01 thru b03 are the switch identifiers See figures 9 10 NOTE The center button is for hot water only and cannot be used for programmi...

Страница 8: ...r BIB pump will appear in the display As shown in figure 11 3 Using the or button to scroll set Pump speed for the desired ratio using Ratio Chart on page 6 as a guide as shown in figure 12 4 Press En...

Страница 9: ...continuous flow push and hold mode the time value will be 0 00 Shown in figure 13 5 Press Enter to save and proceed to the next set up programming option SEL will appear on the display 6 Continue with...

Страница 10: ...itch that you want to program 4 After two seconds release the Enter switch 5 When the cup or carafe is filled to the desired level release the selector switch 6 The switch is now programmed to automat...

Страница 11: ...s flow push and hold mode Procedure Disable a Selector Switch 1 Push and hold the Enter switch for 8 seconds to enter a programming mode The current temperature setting will appear on the display Refe...

Страница 12: ...e the product BIBs from the machine and connect a BIB of sanitizing solution to the PUMP BIB connector Place an empty decanter or other vessel under the dispense area of the machine Press the San swit...

Страница 13: ...e the Enter Switch until 3 dashed lines appear in the display Discard the contents of the decanter or vessel Prime Pump Feature This feature allows you to enter directly into a Prime Pump mode without...

Страница 14: ...WCO Enterprises Phone 1 800 325 7867 Fax 1 636 925 0029 7 22 09 14 of 29 PN 121314 Product Installation Procedures Open the cutout on the product box and position the BIB fitment into the slotted area...

Страница 15: ...867 Fax 1 636 925 0029 7 22 09 15 of 29 PN 121314 Remove the plastic insert from the BIB fitment as shown in figure 2 Using finger and thumb only to prevent over tightening thread the BIB connector on...

Страница 16: ...Coffee Dispenser NEWCO Enterprises Phone 1 800 325 7867 Fax 1 636 925 0029 7 22 09 16 of 29 PN 121314 Place the product in the storage compartment as shown in figure 4 Position the tubing as shown in...

Страница 17: ...penser NEWCO Enterprises Phone 1 800 325 7867 Fax 1 636 925 0029 7 22 09 17 of 29 PN 121314 Cleaning Sanitizing Instructions Remove product from storage area and disconnect BIB connectors as shown in...

Страница 18: ...CD 1 Liquid Coffee Dispenser NEWCO Enterprises Phone 1 800 325 7867 Fax 1 636 925 0029 7 22 09 18 of 29 PN 121314 Place an empty container in the dispense area of the machine as shown in figure 3 Fig...

Страница 19: ...CO Enterprises Phone 1 800 325 7867 Fax 1 636 925 0029 7 22 09 19 of 29 PN 121314 Connect the sanitizing solution adaptor PN 120513 to the BIB connector for Pump and connect sanitizing BIB PN 120509 a...

Страница 20: ...of 29 PN 121314 Press the Start button to enter sanitizing mode as shown in figure 6 Press the Start button again to begin sanitizing Sanitization cycle will run for 2 1 2 minutes hot water will be de...

Страница 21: ...Coffee Dispenser NEWCO Enterprises Phone 1 800 325 7867 Fax 1 636 925 0029 7 22 09 21 of 29 PN 121314 When cycle is finished remove sanitizing solution and reinstall products as shown in figure 7 Fig...

Страница 22: ...o prime pump as shown in figure 8 Press enter to return to the normal operating mode as shown in figure 9 Flushing Instructions Flush the mixing chamber by pressing and holding the Enter button for 5...

Страница 23: ...meout period Timeout period is 120 seconds which is reloaded whenever the heater is off or the fill valve is on Check element for short and proper resistance Check heater relay Check for tripped butto...

Страница 24: ...ing Tank the tank is empty but the heater is on The control board has either seen a rise in temperature of 1 degree a second for 5 seconds or has seen the temperature rise to 215 F or above The unit h...

Страница 25: ...er NEWCO Enterprises Phone 1 800 325 7867 Fax 1 636 925 0029 7 22 09 25 of 29 PN 121314 Dimensions Electrical Specifications 16 65 4 70 17 48 6 89 Electrical Specs PN 120309 LCD 1 120V 1600W 15 Amps L...

Страница 26: ...LCD 1 Liquid Coffee Dispenser NEWCO Enterprises Phone 1 800 325 7867 Fax 1 636 925 0029 7 22 09 26 of 29 PN 121314 Electrical Schematic...

Страница 27: ...ly Black LCD 1 121299 Display Board Mounting Bracket LCD 1 LCD 1 120336 Membrane Switch LCD 1 LCD 1 120350 Board Display LCD 1 706801 Display Label Board LCD 1 LCD 1 Label door LCD 1 LCD 1 120421 Harn...

Страница 28: ...ffee Pump Motor Bracket Ass y LCD 1 104155 Replacement Pump Head Tubing Check Valve Ass y LCD 1 120493 Tube Assembly BIB LCD 1 120422 Connecto Scholle 1910L LCD 1 107117 Clamp Stepless Ear SS LCD 1 11...

Страница 29: ...ewco prompt notice of any claim to be made under this warranty by telephone at 800 556 3926 or by writing to 3650 New Town Blvd Saint Charles MO 63301 2 if requested by Newco shipping the defective eq...

Отзывы: