TROUBLE SHOOTING GUIDE 

 

SYMPTOM 

POSSIBLE CAUSE 

WHAT TO CHECK 

REMEDY 

CAN’T START BREW CYCLE 

1.  No Water 
2.  No Power 
3.  On/Off Switch 
4.  Brew Start Switch 
5.  Timer/Timer Harness 

Timer/Probe & Harness 

6.  Solenoid Valve 

 

1.  Water bottle is empty? 
2.  Fuse or circuit breaker, 

power cord & plug 
connections 

3.  Switch continuity [normally 

closed 1 & 2] 

4.  Switch continuity [normally 

open] 

5.  Leads to solenoid, switches, 

& level sensor probe. 

6.  (A) Voltage at solenoid 

valve terminals, start a brew 
cycle & check for 120V AC 
(B) If voltage is present at 
terminals, check water on 
the inlet side of solenoid 
valve 
 

1.  Replace empty bottle with 

new one 

2.  Replace or reset circuit 

protector as required, unit 
should be plugged in 
securely 

3.  If On/Off switch does not 

make and break contact 
replace it 

4.  If brew start switch does not 

make & break contact, 
replace it 

5.  Make sure these 

connections are tight, if all 
checks out ok replace timer 

6.  (A) If voltage is not present 

at terminals, refer to steps 2 
thru 5 (B)If voltage is 
present at terminals, water 
is present at the inlet side 
but not at the outlet side of 
the solenoid valve replace it 

NO HOT WATER 

1.  Tank heater 
2.  Hi-limit thermostat or main 

thermostat 

1.  Check voltage at the tank 

terminals, voltage should be 
as indicted on the serial tag 

2.  Check voltage between the 

white wire on the tank & 
incoming terminal [blue 
wire] on the hi-limit 
thermostat, then the 
outgoing terminal [black 
wire] on the hi-limit 
thermostat 

1.  (A) If correct voltage is 

present at the tank heater 
terminals & water not 
heated, replace the tank’s 
heating element (B) If 
voltage is not present at the 
tank heater terminals refer 
to step 2 (c) if incorrect 
voltage is present at the 
tank heater terminals, check 
voltage at outlet 

2.  (A) If voltage is present on 

the incoming terminal of the 
hi-limit thermostat, but not 
on the outgoing terminal, 
replace the hi-limit 
thermostat (B)  Check the 
voltage between the black & 
white wire on the 
receptacle, if voltage is not 
present check outlet or 
circuit breaker (C) If voltage 
is not present on the 
incoming terminal of the hi-
limit thermostat replace the 
main the main thermostat 

STEAMING/SPITTING 
AROUND FUNNEL 

1.  Main Thermostat 
2.  High Altitude 

1.  Thermostat points stuck or 

out calibration 

2.  Located above 5,000 feet 

1.  (A) Adjust thermostat (B) 

Thermostat should be 
calibrated or replace 

2.  See installation instructions 

FAUCET WATER TOO SLOW 

1.  No Water 

1.  (A) Water bottle (B) Faucet 

clogging 

1.  (A) Replace empty bottle 

with new one (B) Clean or 
rebuild faucet 

DRIPPING 

1.  Not siphoning properly 

1.  Water should flow freely 

from the spray head 

1.  (A) Clean spray head holes 

(B) Check tightness of spray 
head tube 

DRY COFFEE REMAINING IN 
BREW BASKET AFTER 
BREWING 

1.  Filter 
2.  Not siphoning properly 
3.  Improper loading of brew 

basket 

1.  Correct filters being used? 
2.  Refer to “Dripping” step 1 
3.  Filter & coffee in brew 

basket 

1.  Insert proper filter 
2.  Refer to “Dripping” step 1 
3.  Filter centered, coffee bed 

level 

 