background image

 

 

P a g e

 | 

1 

 

NEWCO ENTERPRISES 

INSTALLATION, OPERATION, AND SERVICE MANUAL FOR 

KB SERIES BOTTLED WATER BREWERS 

 

 




 

 

Model 

Warmers 

Width 

Depth 

Height 

Weight 

Watts 

Amps 

KB-1F 

9 1/2" 

18” 

20 1/8” 

34 

1500 

12.5 

KB-2F 

18” 

9 1/2" 

22 3/8” 

39 

1600 

13.3 

KB3-F 

16 1/2" 

18” 

20 1/8” 

43 

1700 

14.2 

KB-TCF 

9 1/2" 

18” 

20 1/8” 

34 

1400 

11.7 

KBAPF/LDF* 

9 1/2" 

18” 

26 1/2" 

42 

1400 

11.7 

*We recommend up to 3 gallon bottles only due to stability, unless anchored to wall. 

 

 

 

INSTALLATION INSTRUCTIONS 

WARNING – Read and follow installation instructions before plugging or wiring in machine to electrical circuit. Warranty





FILL BREWER TANK WITH WATER BEFORE CONNECTING TO POWER SUPPLY! 

1.)  Place bottle on top of brewer with neck of bottle extending into receiving hole. 
2.)  Hold faucet open until water flows from it. Allow one minute for automatic leveling of water in tank. Plug or wire brewer to 

appropriate voltage circuit as indicated on serial tag. Place decanter/carafe/airpot under brew basket and turn lower warmer 
switch to the “ON” position. Depress brew start switch & check volume of water delivered into decanter/carafe/airpot. Adjust 
timer to deliver desired amount of water. Turn timer dial clockwise to increase volume of water, and counter clockwise to 
decrease volume. 

3.)  Allow 10 to 15 minutes for water in tank to heat to brewing temperature. Water has reached brewing temperature when 

thermostat clicks off and heating noise stops. Green ready light will be lit on models so equipped. Empty vessels and 
replace. 

4.)  Run one cycle to check for proper temperature setting with an accurate thermometer. Take the temperature of the water at a 

point below the brew basket opening, at the start of the brew cycle, and when the vessel is half full. Recommended 
temperature is approximately 195°F. 

5.)  In higher altitudes [5,000 feet above sea level] the thermostat may have to be adjusted to a lower temperature to prevent 

boiling. 

6.) 

CAUTION

: On faucet models the water faucet will dispense hot water when the handle is depressed. The faucet may be 

operated during brew cycle. 

Man. PN: 781224 

Rev. 20170309 

KB-APF/LDF 

KB-TCF 

KB-3F 

KB-2F 

Vessels Not Included 

Отзывы: