background image

 

MACHINE PROGRAMMING CONT’D

 

 

 

Set Temperature

: In this entry the user may set the tank temperature in the range of

 

170 to 205 degrees Fahrenheit with the default at 200 degrees F. Pressing button D (see Fig 1) 
will toggle the display so the user may view the real tank temperature. The real temperature 
display has all three decimal points illuminated. Pressing button D (see Fig 1) again will switch 
the display back to show the current set point. As with most of the entries, button A and button 
B (see Fig 1) will change the set point, incrementing or decrementing by one. Pressing the Hot 
Water key (G)(see Fig 1) will exit.

 

 

Set Energy Save Mode

: This entry allows the user to select the Power Save mode. 

Use button A and button B (see Fig 1) to change the entry then press the Hot Water (G) key to 
exit.

 

 

Off Mode (default) 

–No Energy Save

 

 

Energy Save

– Partial Power Save Mode. After the user selectable time out the tank 

temperature set point is set to 180 until a key is pressed. When this mode is selected the 
right most decimal point in the display is on.

 

 

Full Energy Save 

– Full Power Save Mode. After the user selectable time out the tank heater 

is disabled until a key is pressed. When this mode is selected the left most decimal point in 
the display is on.

 

 

Set Energy Save Time

: This entry will not be displayed if the Power Save function 

has been turned off. This entry sets the time the machine will operate normally until the power 
save function is activated. The user can choose 1 through 4 hours in 1-hour increments with the 
default set to 4 hours. As with most of the entries, button A and button B (see Fig 1) will change 
the time, incrementing or decrementing by one. Pressing the Hot Water key (G) (see Fig 1) will 
exit.

 

 

Set Buzzer Volume

: The range is from 1 to 24. The default is 13.

 

 

Set Air Pump Speed

: In this entry the user may set the air pump strength in the range 

of 5 to 10 strength with the default at 9. As with most of the entries button A and button B (see 
Fig 1) will change the Air Pump Strength, incrementing or decrementing by one. Pressing the 
Hot Water key (G)( (see Fig 1) key will exit.

 

 

Set Air Pump Time

: In this entry the user may set the air pump time in the range of 2 to

 

10 seconds with the default at 5. As with most of the entries button A and button B (see Fig 1) 
will change the Air Pump Time, incrementing or decrementing by one. Pressing the Hot Water 
key (G) (see Fig 1) key will exit.

 

 

Set Pod Count

: In this entry the user may set the number of pods the brewer will hold 

before signaling that the bin is full. The range is 10 to 100 pods, with the default at 40. Setting

 

the pod count under 10 turns off the count so the bin full alarm will never go off. As with most of 
the entries button A and button B (see Fig 1) will change the Pod Count threshold, incrementing 
or decrementing by one. Pressing the Hot Water key (G) (see Fig 1) will exit.

 

Содержание FKP-3

Страница 1: ...P 3 NEWCO ENTERPRISES INC 3650 NEW TOWN BLVD SAINT CHARLES MO 63301 1 800 325 7867 FAX 1 636 925 0029 Features Specifications AUTOMATIC POD REMOVAL FLOWMETER 20 OZ TRAVEL MUG LARGE POD WASTE TRAY THRU...

Страница 2: ...2 LEFT BLANK INTENTIONALLY...

Страница 3: ...SET UP 6 MACHINE OPERATION 7 MACHINE PROGRAMMING 7 DRAINING THE HOT WATER TANK 11 SERVICING THE MACHINE 11 REMOVING THE BREW MECHANISM 11 SIDE PANEL REMOVAL 12 TANK REMOVAL ACCESS AREAS 13 POD BREWING...

Страница 4: ...1700W 120V CANADA 1400W 120V INTERNATIONAL 1700W 220V TANK CAPACITY 1 US GALLON DRIP TRAY CAPACITY 8 OUNCES POD WASTE TRAY CAPACITY 40 PODS USE WASTE TRAY PN 780306 FOR THRU COUNTER USE UP TO 20 OZ C...

Страница 5: ...ranty by telephone at 800 556 3926 or by writing to 3650 New Town Blvd Saint Charles MO 63301 2 if requested by Newco shipping the defective equipment prepaid to an authorized Newco service location a...

Страница 6: ...t run use 1 4 tubing and connect to 1 2 or larger water line The inlet water fitting on the back of the brewer is a 1 4 flare fitting It may be necessary to remove the plumbing cover box on the rear o...

Страница 7: ...BE SHUT OFF AIR PUMP POD DRYING TIME PUMP STRENGTH CAN BE ADJUSTED POD COUNT TO EMPTY POD WASTE BIN AJDUSTABLE OR CAN BE TURNED OFF IF USING THROUGH THE COUNTER WASTE BIN COFFEE OR TEA PRE INFUSTION B...

Страница 8: ...TS ARE NECESSARY IF THE FACTORY DEFAULTS ARE USED G A B C D E F Fig 1 Fresh Cup Keys The Fresh Cup pod brewer has a menu that consist of scrolling menu entries that can be scanned through backward and...

Страница 9: ...unction has been turned off This entry sets the time the machine will operate normally until the power save function is activated The user can choose 1 through 4 hours in 1 hour increments with the de...

Страница 10: ...This entry sets the brew time in seconds for a 7 ounce cup of coffee with on off pulses The range is from 30 to 99 seconds with the default being 35 seconds EXIT Exit to Main Programming Menu Select W...

Страница 11: ...ACE DRAIN PLUG ENSURE HOSE CLAMP IS TIGHT AND REPOSITION DRAIN HOSE BEFORE RE FILLING THE HOT WATER TANK SERVICING THE MACHINE The Fresh Cup machine has a modular Water Tank Assembly and Brew Mechanis...

Страница 12: ...AL 1 LOOSEN 2 SCREWS THEN REMOVE COVER PANEL 3 SLIDE PANEL TO THE REAR OF THE MACHINE 2 REMOVE 2 SCREWS FROM REAR OF SIDE PANEL 4 LIFT PANEL UP AND RELEASE TOP FLANGE 5 SLIDE PANEL DOWN 6 SLIDE PANEL...

Страница 13: ...ANK ONE ON BOTTOM OF PUMP BRACKET LOOSEN SCREWS TO REMOVE TOP BACK COVERS LOOSEN BUT DO NOT REMOVE THESE 2 SCREWS THEN LIFT PULL CONTROL BOARD BRACKET OUT OF MACHINE TO ACCESS TRANSFORMER REMOVE 2 6 3...

Страница 14: ...246 U CUP SEAL RING 1 5 780257 UPPER BREW CHAMBER 61MM 1 6 780554 EJECT SLOPE CAM ASS Y 1 7 780528 MOLDED BUMP DISC PAD 1 8 780422 X 3 16 NYLON SPACER 1 9 780546 KICKER SLIDE WASHER 1 10 780254 X 1 ST...

Страница 15: ...5 780253 TANK ONLY 1 6 773056 AIR PUMP POD 1 7 500396 LIQUID LEVEL PROBE BUSHING 2 8 151677 DUAL TEMP THERM PROBE 1 9 100149 ELBOW C X 1 8 NPT 1 10 704166 10 1700W 704161 10 1400W TANK HEATING ELEMEN...

Страница 16: ...AL COMPONENTS 5 4 2 3 1 ITEM NEWCO PN DESCRIPTION QTY EA 1 780608 CONTROL BOARD BRACKET 1 2 110626 SWITCH DPST ON OFF 1 3 102383 SOLENOID FILL VALVE 1 4 105115 TRANSFORMER 120VAC 24VAC 1 5 780601 DISP...

Страница 17: ...IVE MOTOR ERROR CHECK FOR JAM OR OBSTRUCTION IN BREW CHAMBER Message BOARD ERROR CONTROL BOARD WRITE ERROR REPLACE BOARD IF MESSAGE DOES NOT CLEAR PN 780602 Message FILL TIMEOUT ERROR WATER NOT REACHI...

Страница 18: ...18 WIRING DIAGRAM...

Страница 19: ...19...

Страница 20: ...20 LEFT BLANK INTENTIONALLY...

Страница 21: ...21 LEFT BLANK INTENTIONALLY...

Отзывы: