MIG 500
16
3.4 Standard Display Functions
MIG400
Power Source
11
SECTION 4 — OPERATION
4.2.7 Standard display functions:
USER Configuration Menu
Reachable after long encoder button press (~3s) and indicated by flashing 3 LED diodes
To save changes, press long encoder button (~3s)
A
Activity Time
T
Total ON Time
C.U.
Cooling Unit Control
Er.
Errors Register
CodE
Service Code
drU
Control PCB Current Status
SERVICE Functions
USER
A
.8.8.8.
8.
1
.
0
.
'
.
Activity time (hours)
Shows time how long current flow was detected
A
.8.8.8.
8.
2
.
4
.
' '
.
Activity time (minutes)
t
.8.8.8.
8.
1
.
0
.
'
.
Total ON time (hours)
Shows time how long device was ON
T
.8.8.8.
8.
2
.
6
.
' '
.
Total ON time (minutes)
C
.
U
.8.8.
8.
o
.
F
.
F
.
Cooling Unit
Error Register
Cooling unit disconnected or not active.
Signal from cooling unit is ignored.
C
.
U
.8.8.
8.8.
O
.
n
.
Cooling unit is connected.
Stand-by function
not active
.
C
.
U
.8.8.
8.
6
.
O
.
n
.
Cooling unit is connected.
Stand-by function
active
Active only in communication mode
Set time range 2..30min
E
.
r
.8.
2
.
8.8.8.
4
.
Error Register
Display counter for each type of error
(during service mode long press will reset all counters
and display text ErCL)
C
.
O
.
d
.
E
.
-
.
-
.
-
.
-
.
Service Code Enter
Function available only once correct start-up sequence
conducted (2).
Enter correct service code by turning encoder and press
button to access service functions
User Configuration Menu