NewAire 852551003227 Скачать руководство пользователя страница 7

— 7 —

AC CONNECTION

u

  Plug into properly 

installed and 
grounded three-
prong outlet. See 
safety precautions as 
follows.

STANDARD OPERATION 

u

  Press the Power Switch to the ON position and the 

Hydroxyl Ozone Generator will operate continuously 
until the Power switch is set to OFF. The Continuous 
indicator will light when the switch is set to ON.

 

NOTE

: The Ozone feature cannot be used while in 

the Continuous mode. 

 

When done, press the Power Switch to the OFF 
position and the fan and UV bulbs will turn off.

Operation

Grounding Instructions 
THIS APPLIANCE MUST BE GROUNDED.

  

In the event of an electrical short circuit, grounding 
reduces the risk of electric shock by providing an 
escape wire for the electric current. This appliance is 
equipped with a cord having a grounding wire with 
a grounding plug. The plug must be plugged into an 
outlet that is properly installed and grounded. 
•   Plug into properly installed and grounded three-

prong outlet. 

•   DO NOT remove ground prong. 
•   DO NOT use an adapter.

Power Supply

 

•  Extension cords can be used only if:
  (1)  the marked electrical rating of the extension 

cord is at least as great as the electrical rating of 
the appliance, 

  (2)  the extension cord must be a grounding-type 

three-wire cord, and 

  (3)  the longer cord should be arranged so that it 

will not drape over the countertop or tabletop.

3-Pronged Plug

Ground Plug

3-Prong Receptacle

Содержание 852551003227

Страница 1: ...t safety and maintenance information Keep these instructions for future reference These instructions contain important safety and operating information for your Newaire HO3 2500 Hydroxyl Ozone Generat...

Страница 2: ...ies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received includin...

Страница 3: ...ed or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped 15 WARNING To reduce the risk of fire or electric shock do...

Страница 4: ...tip Keep the eyedropper at an angle to stop the mercury from rolling back out until you can put the mercury into the plastic bag Wrap tape sticky side out around your gloved fingers and carefully use...

Страница 5: ...intensity of the problem With odors usually this unit can permanently eradicate them within a few days Is humidity good or bad to have with this unit Good The higher the treatment area s humidity the...

Страница 6: ...f Controls Plastic End Cap HYDROXYL TIMER Knob CONTINUOUS Indicator OZONE TIMER Knob CAUTION OZONE ON Indicator Carrying Handle Power Switch OZONE Switch Plastic End Cap Fuse bottom of unit AC Cord bo...

Страница 7: ...of an electrical short circuit grounding reduces the risk of electric shock by providing an escape wire for the electric current This appliance is equipped with a cord having a grounding wire with a...

Страница 8: ...been reached the fan and UV bulbs will turn off w OZONE Can only be used when Hydroxyl Timer is set also and room must be empty of people pets and plants Set the desired ozone time using OZONE TIMER...

Страница 9: ...the new carbon filter then replace the screen and plastic end cap x Re insert the two screws y Repeat for the other carbon filter located on the opposite side IMPORTANT The unit should never be opera...

Страница 10: ...one of the 8 32 screws holding the finger guard in its place and loosen the opposing screw Rotate finger guard 180 so it is out of the way to access the UV Bulb area x Loosen both socket head screws...

Страница 11: ...ign the bottom end of the UV bulb into the bottom recess V Reconnect the UV Lamp then reinsert socket head screws and gently tighten with 3 32 Allen key W Repeat process with the second UV lamp as the...

Страница 12: ...s WARNING UV Bulbs MUST be disposed of properly see pages 4 and 5 for details on removing the mercury containing UV bulbs at Reinsert carbon filter metal retaining screen and plastic end cap then secu...

Страница 13: ...rol panel Lift upper cabinet cover clear of the machine w Remove two screws one on each generator tube Loosen do not remove the screw in the middle of the tubes holding the titanium electrode to the w...

Страница 14: ...e and electrode screws Replacement Parts Cleaning Fuses To order replacement parts contact your distributor or call 1 866 676 9663 for assistance Cleaning To clean use a damp soapy cloth for standard...

Страница 15: ...66 676 9663 for service Generator is not performing well The life of the carbon filter may have been met or damaged replace both carbon filters see page 9 The life of the UV bulb may have been met or...

Страница 16: ...ARRANTY REPAIR CENTER AT THE TIME REQUEST FOR REPAIR IS MADE EVIDENCE OF THE DATE OF PURCHASE AND DATES OF MAINTENANCE WORK MUST BE PROVIDED UPON REQUEST TRANSPORTATION COSTS SHALL BE BORNE BY THE PUR...

Страница 17: ...QUEENAIRE TECHNOLOGIES INC 9483 State Highway 37 Ogdensburg NY 13669 www queenaire com...

Отзывы: