NewAir NWC033SS01 Скачать руководство пользователя страница 5

 

newair.com 

sure the power line of the unit is disconnected. 

 

Do not connect or disconnect the electric plug when your hands are wet. 

 

Unplug the appliance or disconnect power before cleaning or servicing. 
Failure to do so can result in electrical shock or death. 

 

Do not attempt to repair or replace any part of your appliance unless 
it is specifically recommended in this manual. All other servicing 
should be referred to a qualified technician. 

 

This appliance is CFC- and HFC-free and contains small quantities of 
Isobutane (R600a) which is environmentally friendly, but flammable. It does 
not damage the ozone layer, nor does it increase the greenhouse effect. 
Care must be taken during transportation and setting up of the appliance 
that no parts of the cooling system are damaged. Leaking coolant can ignite 
and may damage the eyes. 

 

In the event of any damage: 

-  Avoid open flames and anything that creates a spark, 
-  Disconnect from the electrical power line, 
-  Air the room in which the appliance is located for several minutes, and 
-  Contact the Service Department for advice. 

 

The more coolant there is in an appliance, the larger the room it should be 
installed in. In the event of a leakage, if the appliance is in a small room, 
there is the danger of combustible gases building up. For every ounce of 
coolant, at least 325 cubic feet of room space is required. The amount of 
coolant in the appliance is stated on the data plate on the back of the 
appliance. It is hazardous for anyone other than an authorized Service 
Person to carry out servicing or repairs to this appliance. 

 

Take serious care when handling, moving, and using the appliance to avoid 
either damaging the refrigerant tubing or increasing the risk of a leak. 

 

Replacing component parts and servicing shall be done by factory authorized 
service personnel so as to minimize the risk of possible ignition due to 
incorrect parts or improper service. 

FOLLOW WARNING CALL OUTS BELOW ONLY WHEN 
APPLICABLE TO YOUR MODEL 

 

Use two or more people to move and install appliance. Failure to do so can 
result in back or other injury. 

 

To ensure proper ventilation for your appliance, the front of the unit must 
be completely unobstructed. Choose a well-ventilated area with 
temperatures above 50°F (10°C) and below 100°F (38°C). (Optimum 
operation occurs within the range 72° to 78°F, or 23°-26°C.). This unit must 
be installed in an area protected from the elements, such as wind, rain, 
water spray or drips. 

Содержание NWC033SS01

Страница 1: ...33 Bottle Wine Cooler SKU NWC033SS01 OWNERS MANUAL Read and save these instructions Manual v1 0...

Страница 2: ...Assembly Installation 8 Operating Instructions 10 Cleaning Maintenance 12 Troubleshooting 14 Limited Manufacturer s Warranty 16 SPECIFICATIONS MODEL NO NWC033SS01 VOLTAGE 110V 120V NOISE LEVEL 43dB F...

Страница 3: ...offers Registering your product information online is safe secure and takes less than 2 minutes to complete Alternatively we recommend you attach a copy of your sales receipt below and record the foll...

Страница 4: ...you know what can happen if the instructions are not followed IMPORTANT SAFEGUIDES Before the appliance is used it must be properly positioned and installed as described in this manual please read th...

Страница 5: ...rger the room it should be installed in In the event of a leakage if the appliance is in a small room there is the danger of combustible gases building up For every ounce of coolant at least 325 cubic...

Страница 6: ...Keep fingers out of the pinch point areas Clearances between the door and between the door and cabinet are necessarily small Be careful closing doors when children are in the area Do not store explosi...

Страница 7: ...7 newair com PARTS LIST...

Страница 8: ...n it is fully loaded To level the unit adjust the front leveling legs For free standing installation leave 5 inches 127mm of space around the back and sides of the unit to allow proper air circulation...

Страница 9: ...njury the cord should be secured behind the appliance and not left exposed or dangling The appliance should always be plugged into its own individual electrical outlet which has a voltage rating that...

Страница 10: ...64 F 5 18 C may not be reached Temperature range 5 18 C 41 64 CONTROL PANEL TOUCH CONTROL ON OFF POWER Press button for 3 seconds to turn on or turn off the appliance LIGHT SETTING Press button to tu...

Страница 11: ...time There should not be a problem once the unit has been running for a few hours DEFROSTING This appliance requires no manual defrosting During the operation of the compressor ice will build up on t...

Страница 12: ...affect the temperature of your appliance if you minimize the number of times the door is opened If the power is going to be off for a longer period of time you need to take the proper steps to protec...

Страница 13: ...f the room away from heat producing appliances and out of direct sunlight Ensure that the unit is adequately ventilated Do not keep the door open any longer than necessary CAUTION Failure to unplug th...

Страница 14: ...erly The door is not sealing properly Insufficient free space around the appliance The compressor starts and stops frequently The external temperature is high A large quantity of bottles has been put...

Страница 15: ...Possible Causes and Solution The door does not close properly The appliance is not level The door seal is dirty or damaged The shelves are not positioned correctly A part of the contents is preventing...

Страница 16: ...upply such as low voltage defective household wiring or inadequate fuses Accident alteration misuse or abuse of the appliance such as using non approved accessories inadequate air circulation in the r...