NewAir AC14000E Скачать руководство пользователя страница 2

BEFORE USE 

 

GENERAL SAFETY INSTRUCTIONS: 

 

ALWAYS OPERATE THE UNIT IN AN UPRIGHT 

POSITION AND PLACE IT ON A FLAT, LEVEL 

SURFACE AT LEAST 14” (36 CM) FROM ANY 

OBJECTS OR COMBUSTIBLE SURFACES (FIG 1 & 

4). 

 

DO NOT PLACE OBJECTS ON THE UNIT, AND DO 

NOT COVER OR OBSTRUCT THE INLET OR OUTLET 

GRILLS (FIG 2).   

 

CLOSELY SUPERVISE ANY CHILDREN AND PETS 

WHEN THE UNIT IS IN USE.   

 

THIS APPLIANCE IS NOT INTENDED FOR USE BY 

PERSONS (INCLUDING CHILDREN) WITH REDUCED 

PHYSICAL, SENSORY OR MENTAL CAPABILITIES, 

OR LACK OF EXPERIENCE AND KNOWLEDGE, 

UNLESS THEY HAVE BEEN GIVEN SUPERVISED TO 

ENSURE THAT THEY DO NOT PLAY WITH THE 

APPLIANCE.   

 

ELECTRICAL SAFETY:  

 

THIS APPLIANCE IS FOR INDOOR USE ONLY. 

 

ALWAYS TURN OFF THE UNIT AND UNPLUG IT 
WHEN NOT IN USE.   

 

DO NOT USE THIS UNIT IN EXCESSIVELY HUMID 
OR WET ENVRIONMENTS (FIG 3).   

 

DO NOT PULL OR PLACE STRAIN ON THE 
POWER CORD WHEN MOVING THE APPLIANCE. 

 

IF THE POWER CORD IS DAMAGED, IT MUST BE 
REPLACED BY AN ELECTRICIAN OR 
SPECIALIZED TECHNICIAN AUTHORIZED BY THE 
MANUFACTURER IN ORDER TO PREVENT FIRE.   

 

 
FOR MAXIMUM EFFICENCY:  

 

Make sure doors and windows are closed while the 
portable air conditioner is in use.  Also keep curtains 
and blinds closed during the sunniest parts of the day 
while the air conditioner is in operation.   

 

Frequently clean the portable air conditioner’s filters. 

 

Once the room or area has reached your desired 
comfort level, be sure to reduce the unit’s temperature 
and ventilation settings.  

 

 

 

 

 

1

   

FIG. 1

 

 

 FIG. 2

 

 

FIG. 3

 

 

FIG. 4

 

   

 

 

 

 

 

 

 

 

   

 

 

 

K0080-1-2

Содержание AC14000E

Страница 1: ...PLEASE READ AND SAVE THESE INSTRUCTIONS NewAir AC 14000E AC 14000H Portable Air Conditioner Owner s Manual K0080 1 2...

Страница 2: ...APPLIANCE IS FOR INDOOR USE ONLY ALWAYS TURN OFF THE UNIT AND UNPLUG IT WHEN NOT IN USE DO NOT USE THIS UNIT IN EXCESSIVELY HUMID OR WET ENVRIONMENTS FIG 3 DO NOT PULL OR PLACE STRAIN ON THE POWER CO...

Страница 3: ...ber plug drainage hole Accessories 10 Hose adapter goes over the exhaust hose and into the back of the unit 11 Exhaust hose 12 Round connector to be used in between the hose and window kit or through...

Страница 4: ...rt the other end of the exhaust hose into the window kit s round opening Open your window and insert the window kit into the open gap Adjust the size of the kit if necessary by sliding the window acro...

Страница 5: ...to accumulate resulting in overheating and unexpected shut offs The exhaust hose may be extended from 12 300 mm to 59 1500 mm but for maximum efficiency use the shortest hose length possible WARNING...

Страница 6: ...filters from the filter frames 3 Remove the activated carbon filters from their plastic bags 4 Attach the activated carbon filters onto the filter frames 5 Re fix the filters to the filter frames mak...

Страница 7: ...6 7 Swing button 8 Sleep mode indicator 9 Sleep mode button 10 Temperature decrease button 11 Temperature display 12 Remote control receiver 13 Timer display 14 Temperature increase button 15 Timer bu...

Страница 8: ...ature If no temperature is set the display will show the ambient room temperature 3 Please note that the default temperature for cooling is 75 o F and 68 o F for heating Setting the Fan Ventilation Sp...

Страница 9: ...the unit is in fan dehumidification or auto mode It will only work in cooling or heating mode Swing Function 1 To activate the unit s swinging louvers press the SWING button The louvers will rise in...

Страница 10: ...The cooling system will turn off if the ambient temperature is lower than the set temperature However the fan will continue operating at the set level Once the ambient temperature rises above the set...

Страница 11: ...plug it from the wall socket To prevent water leakage avoid moving the unit when full 2 Place a container such as a small pan underneath the drainage hole 3 Remove the drain knob and rubber plug from...

Страница 12: ...g 18 FIG 17 The drain tube may be extended by adding an extension tube with a suitable connector FIG 18 Please Note 1 The drain must be at or below the level of the drainage port 2 The full water tank...

Страница 13: ...se and window kit are properly installed refer to page 4 for instructions 2 Set up the air conditioner for continuous drainage using the included drain tube refer to page 12 for instructions FIG 20 3...

Страница 14: ...or tap the filter lightly to remove loose dust and dirt from the filters Rinse the filters under running water no warmer than 104o F Thoroughly dry the filters before replacing it back into the unit...

Страница 15: ...re too many windows or doors open y Are there too many people in the room y Are there additional heat sources in the room y Is the filter dusty or dirty y Is the air inlet or outlet blocked y Is the a...

Страница 16: ...hours Exhaust Pipe Dimensions 5 6 X 59 1 Net Weight 72 8 lbs Product Dimensions 17 7 x14 4 x 32 5 Notes 1 Heating function is only for model number AC 14000H 2 The data marked with may vary for techni...

Отзывы: