13
Count On NewAir
CONTINUOUS DRAINAGE
1.
Remove the water plug from the drainage port and retain it for future
use.
2.
Connect the drainage hose included with unit to the drainage port as
shown.
3.
Connect the other end of the hose into a drain.
Please note:
The drain must be at or below the level of the drainage port.
The full water tank indicator will not work when the unit is being continuously drained.
To extend the drainage hose, you can connect it with another hose with an overall diameter of 0.7” (18
mm).
If room humidity levels are over 85%, it will be necessary to continuously drain the unit using the drainage
hose.
H
EATING
M
ODE
These instructions apply only to model no. AC-12000H. While using the heating function, please note:
In order to properly exhaust cool air, make sure the exhaust hose and window kit are properly installed.
Set up the air conditioner for continuous drainage using the drain tube.
The working range for the heating function is 32°F to 68°F. The unit may not provide optimal heating if used in
temperatures outside this range.
CLEANING & MAINTENANCE
CLEANING YOUR PORTABLE AIR CONDITIONER
Always unplug the unit from the power supply before cleaning. To maximize the efficiency of the air
conditioner, regularly clean the unit.
C
LEANING THE
H
OUSING
Use a soft, damp cloth to wipe the body clean.
Never use strong chemicals, gasoline, detergents, chemically-treated cloths, or any other cleaning
solutions to clean the air conditioner, as these can all potentially damage the unit’s housing.