INSTALLATION INSTRUCTIONS - ELECTRIC
CONNECT TO THE ELECTRICITY
SUPPLY
Your appliance will be fitted with one of
the adjacent terminal blocks, please refer
to the wiring diagrams on the following
pages for phase link connections, to
ensure correct supply cable connection to
your appliance.
Warning:
This appliance must be earthed.
This appliance is not intended to be oper-
ated by means of an external timer or
separate remote control system.
We recommend that the appliance is con-
nected by a competent person who is a
member of a competent persons scheme
using a double pole control unit of 32
ampere minimum capacity with 3mm
minimum contact separation at all poles.
1. Access to the mains terminal is gained
by opening the terminal block cover at
the rear of the appliance (use a small flat-
bladed screwdriver).
2. connection must be made with a suit-
able flexible cord.
3. First strip the wires, then push the
cable through the cable clamp in the
terminal block cover.
4. Connect the cable to the terminal block
and tighten the cable clamp screw (see
diagram).
5. Close the terminal box, ensuring that
the cover is engaged on the locking tabs.