Hydraulic Alarms
Alarm
Description
Trigger
Conveyor
Hydraulic
Pressure Exceeds
Maximum
“Conveyor Hydraulic Pressure Exceeds
Maximum Operating Range�”
Conveyor hydraulic pressure exceeds
[Max Conveyor Hydraulics Pressure]
setting for a period of five consecutive
seconds or longer�
System Hydraulic
Pressure Exceeds
Maximum
“System Hydraulic Pressure Exceeds
Maximum Operating Range�”
System hydraulic pressure exceeds [Max
System Hydraulics Pressure] setting for
a period of five consecutive seconds or
longer�
Hydraulic Fluid
Level Low
“Hydraulic Fluid Level Low�”
Hydraulic fluid level has fallen below
lowest level tank sensor�
Hydraulic Fluid
Temperature
Below Minimum
“Hydraulic Fluid Temperature Below
Minimum Operating Range�”
Hydraulic temperature is below 65°F
(18°C). Hydraulic fluid too cold to
operate machine�
Hydraulic Fluid
Temperature
Exceeds
Maximum
“Hydraulic Fluid Temperature Exceeds
Maximum Operating Range�”
Hydraulic temperature exceeds
maximum operating range, greater than
or equal to 200°F (93°C)�
Hydraulic Filter
Restriction
Detected
“Hydraulic Filter Restriction Detected�”
Hydraulic filter pressure is greater than
or equal to 25 psi for five consecutive
seconds or longer�
Bin Sequencing Alarms
Alarm
Description
Trigger
Container
Advance
Moving to next container in the
sequence�
At the point when the [Container
Advance] criteria has been met�
End of Sequence
End of container sequence, do you
wish to start the sequence from the
beginning?
At the point the last container in the
sequence has met the [Container
Advance] criteria�
Chain Oiler Alarms
Alarm
Description
Trigger
Disable Spinners
Manually disable or shut off the spinner
hydraulic circuit�
The point the user selects to run the
chain oiler routine�
Enable Spinners
Return the spinner hydraulic circuit to a
field ready condition.
The point the user exits the chain oiler
routine�
Conveyor
Lubrication
Required
Conveyor Chain Lubrication Is Required�
[Service Reminder On] setting is enabled
and [Service Reminder Interval] has
expired�
Controller Operations
Содержание AGCO NL4258
Страница 6: ...Insert Current New Leader Warranty Warranty...
Страница 41: ...41 NL4258 4330G4 EDGE www NewLeader com 800 363 1771 312521 AA C Insert Installation Single Bin...
Страница 42: ...42 www NewLeader com 800 363 1771 312521 AA C NL4258 4330G4 EDGE Insert Installation MultApplier...
Страница 44: ...44 This page is intentionally left blank www NewLeader com 800 363 1771 312521 AA C NL4258 4330G4 EDGE Notes...
Страница 54: ...54 This page is intentionally left blank www NewLeader com 800 363 1771 312521 AA C NL4258 4330G4 EDGE Notes...
Страница 78: ...78 This page is intentionally left blank www NewLeader com 800 363 1771 312521 AA C NL4258 4330G4 EDGE Notes...
Страница 106: ...106 www NewLeader com 800 363 1771 312521 AA C NL4258 4330G4 EDGE Notes This Page Intentionally Left Blank...