![New Japan Radio NJT8103 series Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/new-japan-radio/njt8103-series/njt8103-series_instruction-manual_1677937018.webp)
NJT8103 series Instruction Manual
Page 18
Step 2:
Use self-amalgamating tape to seal connector and cable entry
points from the connector to the cable sheath.
Only input a voltage within the range indicated in specified
voltage.
DO operate at the input voltage of +12 to +30 V DC power at
the coaxial connecter on the Unit.
DO NOT input an IF signal over the range of +13 dBm
maximum and a reference signal within the range of -5 to +5
dBm.
6.2. Connecting Modem
The Unit is connected the modem.
6.2.1. Connecting Coaxical Cable.
The Unit receives the reference and the IF signal and is required to supply
+12 to +30 V DC power from the modem via coaxial cable.
IM-T8103 Rev.01
When connecting the coaxial cable from the modem, follow the following
steps:
Step 1:
Connect the coaxial cable with the N or F-type male connectors
to the coaxial connecter equipped with the Unit which is shown
in a figure below under 0.68 to 1.13 N
・
m torque.
Location of Coaxial Connector
Supplied the IF/Ref./DC Power
via Coaxial Cable