background image

Model 8742 Series Quick Start Guide                  90066735 Rev. E                           Page 12 of 16 

 

CAUTION 

The case of the Model 8742 Picomotor Controller/Driver is used 
to dissipate internally-generated heat.  Blocking the normal 
convective airflow around the unit, or thermally insulating the 
unit, can result in severe injury, damage to the product, and/or 
fire. 

 
 

 

CAUTION 

When operated at higher pulse rates for extended periods of 
time, the temperature on the outside of the Model 8742’s case 
may rise above the “surface temperature limits in normal 
operation” as defined in EN61010-1:2010 unless the user takes 
appropriate measures.  These may include the addition of an 
external heat sink, barriers to contact, reducing the pulse 
frequency, or other appropriate mitigations.  Failure to take 
appropriate action when operating the Model 8742 under these 
conditions can result in severe injury.  

 
 
 
 

CAUTION 

The case of the Model 8742 Picomotor 
Controller/Driver is used to dissipate 
internally-generated heat.  Blocking the 
normal convective airflow around the unit, 
or thermally insulating the unit, can result 
in severe injury, damage to the product, 
and/or fire. 

 
 

 

The Model 8742 Picomotor Controller/Driver is intended for use 
in an industrial laboratory environment.  Use of this product in 
other environments, such as residential, may result in 
electromagnetic compatibility difficulties due to conducted as 
well as radiated disturbances.  

 

 

The Model 8742 Picomotor Controller/Driver is intended for use 
in an industrial laboratory environment.  Use of this product in 
other environments, such as residential, may result in 
electromagnetic compatibility difficulties due to conducted as 
well as radiated disturbances.  

 

 
 

 

Содержание Picomotor 8742

Страница 1: ...version of the User s Manual can be found at www Newport com on the product s web page Safety The Model 8742 User s Manual contains numerous safety warnings and cautions The user must read it prior to applying power to the Model 8742 Picomotor Controller Driver Voltages of up to 130 V are accessible inside the Controller and Picomotors devices DO NOT operate with the Controller cover removed If th...

Страница 2: ...2013 EMC Conducted Disturbances induced by Radio Frequency Fields Immunity Test IEC 61000 4 8 2009 EMC Power Frequency Magnetic Field Immunity Test IEC 61000 4 11 2004 AMD 1 2017 EMC Voltage Dips Short Interruptions and Variations Immunity Test 1 Manufacturers Name MKS Instruments Inc 2 Tech Drive Andover MA 01810 USA Authorized Representatives Name Location MICRO CONTROLE Spectra Physics S A S Zo...

Страница 3: ... 2013 EMC Conducted Disturbances induced by Radio Frequency Fields Immunity Test IEC 61000 4 8 2009 EMC Power Frequency Magnetic Field Immunity Test IEC 61000 4 11 2004 AMD 1 2017 EMC Voltage Dips Short Interruptions and Variations Immunity Test 1 Manufacturers Name MKS Instruments Inc 2 Tech Drive Andover MA 01810 USA Authorized Representatives Name Location MICRO CONTROLE Spectra Physics S A S Z...

Страница 4: ...grams as trade secrets of New Focus Customer shall not at any time disclose New Focus s trade secrets to any other person firm organization or employee that does not need consistent with Customer s right of use hereunder to obtain access to the New Focus Programs and Related Materials These restrictions shall not apply to information 1 generally known to the public or obtainable from public source...

Страница 5: ... that documentation needs to be consulted to determine the nature of a potential hazard and any actions that have to be taken 1 1 2 Electric Shock Electrical Shock Symbol The Electrical Shock Symbol in the figure above appears throughout this manual and on the product This symbol indicates a hazard arising from dangerous voltage Any mishandling could result in irreparable damage to the equipment a...

Страница 6: ...pment means that this instrument has been designed tested and certified compliant to all applicable United Kingdom regulations and recommendations 1 1 6 Alternating voltage symbol Alternating Voltage Symbol This international symbol implies an alternating voltage or current 1 1 7 On I On Symbol The symbol in the figure above represents a power switch position on a Model 8742 This symbol represents...

Страница 7: ... Equipment WEEE WEEE Directive Symbol This symbol on the product or on its packaging indicates that this product must not be disposed with regular waste Instead it is the user responsibility to dispose of waste equipment according to the local laws The separate collection and recycling of the waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recy...

Страница 8: ...l applicable product and workplace safety regulations Specific attention should be directed to the description of safety grounding concerns described in Section 1 3 below The following are definitions of the Warnings Cautions and Notes that are used throughout this manual to call your attention to important information regarding your safety the safety and preservation of your equipment or an impor...

Страница 9: ...nect power to the 8742 Do not position the external power supply so that its MAINS power cord cannot be easily disconnected Disconnect power before cleaning the equipment Do not use liquid or aerosol cleaners use only a damp lint free cloth Lockout all electrical power sources before servicing the equipment There are no user replaceable fuses in this equipment The user must ensure that appropriate...

Страница 10: ...nsure that all applicable regulatory requirements are met THIS IS THE USER S RESPONSIBILITY WARNING Do not attempt to operate this equipment if there is evidence of shipping damage or you suspect the unit is damaged Damaged equipment may present additional hazards to you Contact New Focus technical support for advice before attempting to plug in and operate damaged equipment WARNING The Model 8742...

Страница 11: ...r Driver Work performed by persons not authorized by New Focus will void the warranty WARNING If this equipment is used in a manner not specified in this manual the protection provided by this equipment may be impaired WARNING This instrument is intended for use by qualified personnel who recognize thermal shock or laser hazards and are familiar with safety precautions required to avoid possible i...

Страница 12: ...tions Failure to take appropriate action when operating the Model 8742 under these conditions can result in severe injury CAUTION The case of the Model 8742 Picomotor Controller Driver is used to dissipate internally generated heat Blocking the normal convective airflow around the unit or thermally insulating the unit can result in severe injury damage to the product and or fire The Model 8742 Pic...

Страница 13: ...e it is not necessary to connect this terminal to a building earth ground New Focus recommends doing so because it will simplify system level compliance with most regulatory requirements Once this connection is made the user must ensure that all other system components are appropriately grounded If the other components are not grounded a damaged Picomotor or its wire could result in a dangerously ...

Страница 14: ...AN link cable 6 inch for daisy chaining Model 8745 RS485 CBL USB cable 3 meter Model 8745 USB CBL L shaped bracket for stacking several units Model 8745 STK KIT Optical table mounting plate kit Model 8745 MTG KIT 8 Axis Kit 12 Axis Kit 8745 USB CBL 8745 PS 8745 PWR CBL 8745 PWR CBL 8745 STK KIT 8745 STK KIT Model 8742 12 KIT 8745 USB CBL 8745 PS 8745 PWR CBL 8745 STK KIT Model 8742 8 KIT 4 Axis Ki...

Страница 15: ...ick Start Guide 90066735 Rev E Page 15 of 16 1 5 Stacking and Interconnecting Units The following figure demonstrates how multiple controllers are typically stacked and i98nterconnected using standard available accessories ...

Страница 16: ...RS 485 connectors that accept standard 3 5mm stereo plugs The two connectors are connected in parallel inside the controller These connections along with RS 485 cable model 8745 RS485 CBL facilitate daisy chain type hook up to simplify the wiring between an external computer and multiple controller units Read controller User s Manual for complete details NOTE Make sure RS 485 cable plug is fully i...

Отзывы: