- 21 -
6) Press the RESET button (one beep) to display the
selected alarm event number
“H *”.
To display other alarm events, repeat steps 3) to 5).
To delete all the alarm events, select
“INIT” in step 3),
then press and hold the maintenance button for three
seconds. (beep pattern: short
–
long
–
short
–
short).
All alarm events are now deleted.
7-4-7. Clock Setting [Mode 6]
Clock is used when recording alarm events.
1) Enter User mode. Press the
▲
/
▼
button to select
“6”.
(each press of the button is followed by one beep)
“DATE” and “6” will be alternately displayed.
2) Press the maintenance button. (one beep)
“YEAR”
and
“ * * * * (year)” will be alternately displayed.
3) Select the item to change with the
▲
button. The
item and its currently set value will be displayed.
When selecting
“YEAR”, for example,
4) Press the maintenance button. (one beep) The currently
set year will be displayed.
5) Change the set value by using the
▲
/
▼
button.
6) Press and hold the maintenance button for three
seconds to confirm the change. (beep pattern: short
–
long
–
short
–
short)
“YEAR” and the set year will be
alternately displayed.
7) To change the other items, repeat steps 3) to 6).
8) Press and hold the RESET button for five seconds
(two beeps) to return to normal operation mode.
(E.g. H1 is selected)
(E.g. Year is currently
set to 2018)
(Back to
normal operation mode)
(E.g. Changed from 2018 to 2019)
(confirmed)
Each press of the
▲
button cycles through:
“YEAR”, “MON” (month),
“DAY”, “HOUR” and “MIN” (minute).
NOTE
Содержание KS-7R
Страница 37: ... 35 Blank Page ...
Страница 38: ... 36 Blank Page ...
Страница 39: ... 37 Blank Page ...