MAGNETO BIOLIFE

 

 

P o r t a b l e ,   w e a r a b l e   m a g n e t o t h e r a p y    

 
 

 

 

 

MANUAL 

 

Instructions for use 

 

 
 

 
 
 
 
 
 
 
 
 
 

 

New Age Italia srl

 

Via De’ Brozzi, 3  -  48022 Lugo (RA) 

Tel.:+39-0545.32019  -  Telefax: +39-0545.369028 

Web: www.newageitalia.it  -  E-mail: [email protected]  

 

 
 
This  document  is  the  property  of  New  Age  Italia  srl.  All  rights  reserved.  It  is  forbidden  to  copy  and  reproduce  it 
through any means, including total or partial photocopying of the content, without the written authorisation of New 
Age Italia srl. 

Содержание MAGNETO BIOLIFE

Страница 1: ...39 0545 32019 Telefax 39 0545 369028 Web www newageitalia it E mail info newageitalia it This document is the property of New Age Italia srl All rights reserved It is forbidden to copy and reproduce i...

Страница 2: ...Rev 01 on 06 05 16 2 24...

Страница 3: ...Rev 01 on 06 05 16 3 24...

Страница 4: ...Select the program 9 3 5 Starting stimulation 9 3 6 Timer Adjustment 9 3 7 Stop terminate therapy 9 3 8 Switch off device 10 3 9 Symbols on the display 10 Cap 4 APPLICATIONS 10 4 1 Therapy sessions 1...

Страница 5: ...S 16 8 1 Power supply 16 8 2 Output features 16 8 3 Other features 16 Cap 9 SYMBOLS 17 Cap 10 STANDARD EQUIPMENT AND ACCESSORIES 17 10 1 Standard equipment 17 10 2 Accessories and consumable material...

Страница 6: ...easy use makes the product extremely innovative in the electromedical devices sector 1 2 W h y u s e M A G N E T O B I O L I F E MAGNETO BIOLIFE enables application of magnetic fields with beneficial...

Страница 7: ...udoarthrosis arthrosis arthritis inflammatory and degenerative arthropathies oedema algodystrophy tendinitis You are advised to consult a doctor for diagnosis and control of the therapy 2 2 C o n t r...

Страница 8: ...re applying magnetotherapy follow the instructions carefully of the doctor prescribing magnetotherapy 3 1 C o n n e c t i o n a n d a p p l i c a t i o n Connect the cable of the applicator to the dev...

Страница 9: ...r t i n g s t i m u l a t i o n When the desired program appears on the display press the START button Once the program is activated on the display the TIMER appears to indicate the remaining time an...

Страница 10: ...g to medical prescription Applications can be carried out every day with the most suitable program for the patient s pathology until the problem is healed or significantly reduced if necessary 2 3 app...

Страница 11: ...Rev 01 on 20 01 2017 11 24 EXAMPLES OF APPLICATIONS SHOULDER APPLICATION ELBOW APPLICATION KNEE APPLICATION ANKLE APPLICATION FOOT APPLICATION WRIST APPLICATION...

Страница 12: ...When the flat battery status is signalled proceed with the recharge cycle To safeguard the battery MAGNETO BIOLIFE is equipped with an auto power off system 5 2 C h a r g e To charge the MAGNETO BIOL...

Страница 13: ...ry connections which would destroy the electronic circuits 5 5 P r e c a u t i o n s f o r u s e 1 Do not throw the old battery in ordinary waste but give it to authorised staff for its disposal 2 Do...

Страница 14: ...mechanical stress e g serious fall the device was subjected to strong overheating e g if left near intense heat sources if you doubt liquids can penetrate inside the power supply unit the casing and...

Страница 15: ...ical device as this may be hazardous for the patient and the device itself The device performs as specified only if surroundings are kept at a temperature between 5 and 40 C and with humidity less tha...

Страница 16: ...otection rating IP20 Safety rating for use near inflammable anaesthetic gases AP or APG Device operation continuous Manufactured in compliance with the following regulations EN 60601 1 2007 Electromed...

Страница 17: ...DIRECTIVE EEC 93 42 AMENDED BY 2007 47 EC WASTE DISPOSAL ACCORDING TO DIRECTIVE 2002 96 ECC AND 2003 108EEC Cap 10 STANDARD EQUIPMENT AND ACCESSORIES 1 0 1 S t a n d a r d e q u i p m e n t Device App...

Страница 18: ...t applicable Voltage fluctuations emission flicker IEC 61000 3 3 Not applicable Table 202 Declaration Electromagnetic immunity Guidance and manufacturer s declaration electromagnetic immunity The MAGN...

Страница 19: ...ed RF transmitters force fields As determined by research on an electromagnetic site a it must be lower than the conformity threshold of each frequency range b Interference may manifest near devices m...

Страница 20: ...olled The user must avoid electromagnetic interference by maintaining a minimum distance between portable and mobile telecommunications equipment and the MAGNETO BIOLIFE device as recommended above ba...

Страница 21: ...B Gialanella G D alessandro R Santoro Terapia fisica pratica ED Marrapese Roma 1997 Vasta Manuale pratico illustrato di terapia fisica ED Marrapese Roma 1998 Cisari G Severini Fisioterapia clinica pr...

Отзывы: