![Neve BCM10/2 MK2 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/neve/bcm10-2-mk2/bcm10-2-mk2_information-manual_1676764006.webp)
IMPORTANT NOTICE
THE BCM10 CONSOLE IS NOT SUPPLIED WITH A GENERIC IEC 3-CORE
AC POWER CABLE BUT IS SUPPLIED WITH THE PSU AC MATING
CONNECTOR ONLY. WHEN WIRED BY A QUALIFIED ELECTRICIAN, THE
EARTH PIN OF THE PSU AC CONNECTOR MUST BE CONNECTED TO A 3-
PIN EARTHED SUPPLY.
IF A REPLACEMENT CABLE IS USED, THEN THE EARTH FROM THE
MAINS SOCKET OR TECHNICAL EARTH TO THE CONSOLE MUST BE
MAINTAINED.
IF ONLY A 2-PIN (NO EARTH) SUPPLY IS AVAILABLE, THEN THE BCM10 CONSOLE
MUST BE INSTALLED BY A QUALIFIED ELECTRICIAN TO ENSURE THAT THE CONSOLE
METALWORK IS PERMANENTLY EARTHED.
THE CONSOLE SHOULD ONLY BE POWERED FROM A SINGLE-PHASE SUPPLY WITH
THE NEUTRAL CONDUCTOR AT EARTH POTENTIAL.
FAILURE TO FOLLOW THESE PROCEDURES AND RECOMMENDATIONS
COULD INVALIDATE THE MANUFACTURER'S WARRANTY
NB.
THE C5V PSU SHOULD BE SET TO THE REQUIRED LOCAL AC VOLTAGE.
HOWEVER, IF THE CONSOLE IS MOVED TO A DIFFERENT LOCATION AND THE AC
OPERATING VOLTAGE APPLIED TO THE PSU HAS CHANGED THEN REFER TO THE
REAR OF THE PSU FOR INSTRUCTIONS ON HOW TO CHANGE THE WORKING I/P
VOLTAGE FOR THE +5V PSU.
NB.
ONLY THE +5V PSU NEEDS TO HAVE IT'S I/P CHANGED TO ACCOMMODATE
DIFFERENT AC VOLTAGES.
THE CHANGE IS ONLY TO BE MADE WITH THIS UNIT UNPLUGGED FROM THE MAINS
SOURCE, BY A QUALIFIED ELECTRICIAN.
- 6 -